Introduction

1.1System Description

The AX410 single input and AX411 dual input conductivity

analyzers have been designed for continuous monitoring and

control of low level conductivity.

The AX450 single input and AX455 dual input conductivity

analyzers have been designed to meet United States

Pharmacopoeia (USP 645) requirements for continuous

monitoring and control of low level conductivity.

They are available in wall-/pipe-mount or panel-mount versions

and can be used with either one or two sensors, each with a

temperature input channel. When used with two sensors,

readings can be compared to produce a range of extrapolated

values.

When making temperature compensated measurements, the

sample temperature is sensed by a resistance thermometer

(Pt100 or Pt1000) mounted in the measuring cell.

Analyzer operation and programming are performed using five

tactile membrane keys on the front panel. Programmed

functions are protected from unauthorized alteration by a

five-digit security code.

1.2PID Control – AX410 and AX450 Analyzers Only

The AX410 and AX450 single input conductivity analyzers

incorporate Proportional Integral Derivative (PID) control as

standard. For a full description of PID control, see Appendix B,

page 78.

1.3AX400 Series Analyzer Options

Table 1.1 shows the range of configurations that are possible for

the AX400 Series analyzers. The analyzer detects the type of

input board fitted for each input automatically and displays only

the operating and programming frames applicable to that input

board type. If no input board is fitted for a second input (Sensor

B), Sensor B frames are not displayed.

Model Analyzer Description Sensor A Sensor B

AX410 Single Input 2-Electrode Conductivity (0 to 10.000 µS/cm) 2-Electrode Conductivity Not Applicable

AX411 Dual Input 2-Electrode Conductivity (0 to 10.000 µS/cm) 2-Electrode Conductivity 2-Electrode Conductivity

AX413 Dual Input 2-Electrode Conductivity and 4-Electrode Conductivity 2-Electrode Conductivity 4-Electrode Conductivity

AX416 Dual Input 2-Electrode Conductivity and pH/Redox(ORP) 2-Electrode Conductivity pH/Redox(ORP)

AX418 Dual Input 2-Electrode Conductivity and Dissolved Oxygen 2-Electrode Conductivity Dissolved Oxygen

AX430 Single Input 4-Electrode Conductivity (0 to 2.000 mS/cm) 4-Electrode Conductivity Not Applicable

AX433 Dual Input 4-Electrode Conductivity (0 to 2.000 mS/cm) 4-Electrode Conductivity 4-Electrode Conductivity

AX436 Dual Input 4-Electrode Conductivity and pH/Redox(ORP) 4-Electrode Conductivity pH/Redox(ORP)

AX438 Dual Input 4-Electrode Conductivity and Dissolved Oxygen 4-Electrode Conductivity Dissolved Oxygen

AX450 Single Input 2-Electrode Conductivity (USP) 2-Electrode Conductivity Not Applicable

AX455 Dual Input 2-Electrode Conductivity (USP) 2-Electrode Conductivity 2-Electrode Conductivity

AX456 Dual Input 2-Electrode Conductivity (USP) and pH/Redox(ORP) 2-Electrode Conductivity pH/Redox(ORP)

AX460 Single Input pH/Redox(ORP) pH/Redox(ORP) Not Applicable

AX466 Dual Input pH/Redox(ORP) pH/Redox(ORP) pH/Redox(ORP)

AX468 Dual Input pH/Redox(ORP) and Dissolved Oxygen pH/Redox(ORP) Dissolved Oxygen

AX480 Single Input Dissolved Oxygen Dissolved Oxygen Not Applicable

AX488 Dual Input Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen

2Operation

2.1Powering Up the Analyzer

1. Ensure the input sensors are connected correctly.

2. Switch on the power supply to the analyzer. A start-up

screen is displayed while internal checks are performed,

then the conductivity measurement readings screen

(Operating Page) is displayed as conductivity measuring

operation starts.

2.2Displays and Controls

The display comprises two rows of 41/2 digit, 7-segment digital

displays, which show the actual values of the measured

parameters and alarm set points, and a 6-character dot matrix

display showing the associated units. The lower display line is a

16-character dot matrix display showing the programming

information.

Measured Values

Conductivity.

Temperature.

Notes.

 The displayed conductivity and temperature readings are the actual measured

values of the sample.

 AX450 analyzers only – if A: Cond.Units is set to USP645 (Section 5.3), the

displayed conductivity reading is the uncompensated conductivity value of the

sample, i.e. its value at the displayed temperature.

Control Mode

Conductivity value.

Control mode.

Use the  and

control.

keys to switch between manual (Manual) and automatic (Auto)

Note. Displayed only if Controller is set to PID – see Section 5.7. page 41.

Control Output

Conductivity value.

Control output (%), manual (Man) or automatic (Auto).

When Control Mode is set to Manual (see above), use the  and

control output between 0 and 100%.

keys to adjust the

Note. Displayed only if Controller is set to PID – see Section 5.7. page 41.

Control Set Point

Conductivity value.

Control set point.

Use the  and

conductivity.

keys to adjust the control set point between 0 and 250%

Note. Displayed only if Controller is set to PID – see Section 5.7. page 41

Temperature Compensated Conductivity Value – AX450 Analyzers Only

Notes.

 This frame is displayed only if A: Cond.Units is set to USP645 – see Section 5.3.

page 21.

 The displayed reading is the temperature compensated conductivity value i.e. the

value it would be at a sample temperature of 25ºC (77ºF).



  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module, Microsoft Windows Embedded Standard 7 P
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module, Microsoft Windows Embedded Compact 7
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190  CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170    CPU module
  • Beckhoff CX5230-0100   CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC
  • Beckhoff  CX5130-0163 CPU module
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161 CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143    CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125  CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121    CPU module
  • Beckhoff CX5130-0115    CPU module
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112 CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100 CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return
  • SAUTER ASF113F122 Damper actuator with spring return
  • SAUTER ASF113F120 Damper actuator with spring return
  • SAUTER ASF112F122 Damper actuator with spring return
  • SAUTER ASF112F120 Damper actuator with spring return
  • SAUTER ASM 124/134 series - ASM134F130 Damper actuator
  • SAUTER ASM 134 series - ASM134SF132 Damper actuator
  • SAUTER ASM 124/134 series - ASM124SF132 Damper actuator
  • SAUTER ASM 124/134 series - ASM124F122 Damper actuator
  • SAUTER ASM 124/134 series - ASM124F120 Damper actuator
  • SAUTER Valve actuator ASM 105S/115S series ASM115SF152
  • SAUTER Valve actuator ASM 105S/115S series ASM105SF152
  • SAUTER Valve actuator ASM 105S/115S series ASM115SF132
  • SAUTER Valve actuator ASM 105/115 series ASM105SF132
  • SAUTER Valve actuator ASM 105/115 series ASM115F122
  • SAUTER Valve actuator ASM 105/115 series ASM115F120
  • SAUTER Valve actuator ASM 105/115 series ASM105F122
  • SAUTER Valve actuator ASM 105/115 series ASM105F120
  • SAUTER Valve actuator ASM 105/115 series ASM105F10
  • SAUTER AKF113S Rotating actuator AKF 112/113 series
  • SAUTER AKF113F122 Rotating actuator AKF 112/113 series
  • SAUTER AKF113F120 Rotating actuator AKF 112/113 series
  • SAUTER AKF112F122 Rotating actuator AKF 112/113 series