The GE RX7i IC698CPE010 CPU features powerful processing capabilities, rich memory configurations, diverse programming language support, flexible communication interfaces, convenient installation and maintenance, etc. It is suitable for various industrial automation control scenarios. The following is a detailed introduction: Performance advantages: High-speed processing capability: Equipped with a 300MHz Intel Celeron processor, it can quickly execute complex control logic and algorithms, meeting real-time control requirements. Large-capacity memory: It features 10MB of battery backup user memory and 10MB of non-volatile flash user memory, capable of storing a large number of programs and data. It supports up to 512 program blocks, with each block having a maximum size of 128KB. Programming and configuration of multiple programming languages: Supports ladder diagrams, structured text, C language and other programming languages, making it convenient for users to choose the appropriate programming method according to their needs. Symbolic variable support: Supports automatic location of symbolic variables, allowing the use of any amount of user memory, thereby enhancing the readability and maintainability of the program. Rich communication interface: It features three isolated serial ports (RS-485, RS-232) and an embedded Ethernet interface, supporting multiple communication protocols such as Modbus RTU slave station, SNP, serial I/O, Ethernet Global Data (EGD), TCP/IP, etc., facilitating data exchange and communication with various devices. Network monitoring function: Supports monitoring PLC data through the network, can connect to up to 16 network servers and FTP, and achieve remote monitoring and management. Installation and maintenance: Easy to install: Adopting the VME64 standard format, it communicates with I/O and intelligent option modules through the rack-mounted backplane, making installation simple and suitable for various industrial environments. Easy maintenance: Supports firmware upgrades within the system, allowing for firmware updates without disassembling the device. Battery-powered calendar clock and configurable memory protection function ensure the integrity of data and the stability of the system. Reliability and security: Stable operation: It features a run/stop switch and remote control function. Programs and configuration data can be locked through software passwords to prevent unauthorized modifications. Status indication: The LED indicator light on the front of the module can display the operating status of the CPU, the activity of the serial port, and the status of the Ethernet interface, facilitating users to promptly understand the operation status of the equipment. To sum up, the GE RX7i IC698CPE010 CPU is a powerful, stable and easy-to-use industrial controller, suitable for various complex automation control scenarios.
The GE RX7i IC698CPE010 CPU is a high-performance central processing unit, specifically designed for industrial automation and control applications. The following are its main parameters: Processor and memory Processor: 300MHz Intel Celeron microprocessor. User memory: 10MB battery backup RAM and 10MB non-volatile flash memory. Memory access: Access the large-capacity memory through the reference table %W. The upper limit of the memory area can be configured to the maximum value of the user's RAM. Programming and Languages Programming languages: Supports ladder diagrams, C language, etc. Program memory: Configurable data and program memory. Program blocks: Up to 512 program blocks are supported, with each block having a maximum size of 128KB. I/O and communication I/O capacity: Discrete I/O (%I and %Q) up to 32Kbits, analog I/O (%AI and %AQ) up to 32K words. Serial ports: Three isolated serial ports, including one RS-485, one RS-232 and one RS-232 Ethernet site manager port. Ethernet interface: Dual 10BaseT/100BaseT/TX (RJ-45 connector) ports, with an internal network switch, supporting automatic negotiation of network speed and duplex mode. Communication protocols: Supports Ethernet Global Data (EGD), TCP/IP (using SRTP), Modbus RTU slave station, SNP, Serial I/O, etc. Other feature clocks: Battery-powered calendar clock. Firmware upgrade: Firmware can be upgraded within the system. Test mode: Supports test editing mode, allowing for the modification of running programs. LED indicator lights: Three CPU LED indicator lights show status, two leds indicate the activity of the serial port, and seven leds indicate the status of the Ethernet interface. Operation control: It can be controlled through a three-position run/stop switch or a remote programmer. Data protection: Program and configuration data can be locked through software passwords. Physical and environmental dimensions and weight: Compact design, weighing 6.3 kilograms. Operating temperature: 32 to 140 degrees Fahrenheit. Compatibility programming software: CIMPLICITY Machine Edition Logic Developer 4.0 or higher version is required for configuration and programming. Module compatibility: Supports 90-70 series discrete and analog I/O, communication and other modules. These parameters demonstrate the powerful functions and flexibility of the GE RX7i IC698CPE010 CPU, which is suitable for various industrial automation and control requirements.
The following is the usage method of the GE RX71 IC698CPE010 RX7i VME 300Mhz CPU: Installation steps Ensure that the rack power is turned off and record the media access control (MAC) address of the device. Firmly install the CPU module into slot 1 of the rack (the specified CPU slot) and ground it. Connect the Ethernet and serial ports. Re-enable the rack power supply. Connect the CMOS battery to any connector. Programming and configuration are carried out using the Proficy Machine Edition PLC-Logic Developer software. Supports programming languages such as ladder diagrams and C language. Configuration data can be protected by password. Communication interface Ethernet interface: Supports 10/100Mbps transmission rate, has automatic negotiation function, and supports full-duplex and half-duplex modes. Using an Ethernet port requires an IP address and a Cat5 cable. Serial ports: including RS-232, RS-485, etc., supporting protocols such as Modbus RTU slave stations, SNP, serial I/O, etc. Serial connections use the SNP protocol. Operation control is remotely controlled through a three-position run/stop switch or a connected programmer and software. Maintenance and Precautions: Regularly replace the lithium battery pack to prevent the loss of RAM memory data. Pay attention to the status of the LED indicator lights on the CPU module to understand the operation, protection and module status. Through the above steps and precautions, the GE RX71 IC698CPE010 RX7i VME 300Mhz CPU can be used and maintained correctly to ensure its stable operation in the industrial automation control system.
When using the IC698CPE010 CPU of the GE RX7i series, the following points should be noted: Installation and configuration of the installation environment: Ensure that the installation environment meets the requirements of industrial control equipment and avoid harsh conditions such as dust, humidity, and high temperature. Installation position: Install the CPU module into slot 1 of rack 0 and ensure it is securely fastened. Power management: Before connecting the power supply, make sure all connections are correct to avoid damaging the equipment. Storage and backup user storage: It includes 10 Mbytes of battery backup user memory and 10 Mbytes of non-volatile flash user memory. Data backup: Regularly back up important programs and data to prevent data loss due to unexpected circumstances. Communication and Network Network connection: Communication is carried out via an embedded Ethernet port or a serial port using the SNP slave protocol. Cyber security: Take appropriate security measures to protect the CPU and control system from unauthorized access and cyber attacks. Regular maintenance and troubleshooting checks: Regularly inspect the CPU's operating status and indicator lights to promptly identify and address potential issues. Troubleshooting: Be familiar with common troubleshooting methods to quickly restore the normal operation of the system. Other precautions: Battery replacement: Pay attention to the battery life and replace it in time to avoid data loss. Firmware upgrade: Before upgrading the firmware, it is essential to back up the current programs and data and strictly follow the upgrade guidelines. By following these precautions, the stable operation and long-term reliability of the GE RX7i IC698CPE010 CPU can be ensured
Address:Xiamen City, Fujian Province, China
TELL:
E-MAIL:gedcs868@gmail.com