SEL-387E Current Differential and Voltage Relay
Apply the SEL-387E Current Differential and Voltage Relay to provide comprehensive
protection, metering, and automation of transformers, reactors, and other power apparatus
Protection
Expand transformer protection capabilities with restricted earth
fault (REF), negative-sequence overcurrent, overexcitation, and
frequency elements. Innovative restraint and blocking prevent false
trips and enhance security while maintaining sensitivity to internal
faults.
Control
Simplify engineering designs with SELogic® control equations for
customizing advanced protection and control schemes. Apply
frequency elements for load shedding and/or load restoration
schemes
Monitoring/Metering
Oscillographic event reports, Sequential Events Recorder (SER)
reporting, and accurate three-phase power metering reduce or
eliminate external recorder and metering requirements. Station
battery voltage monitor, through-fault monitor, and circuit breaker
contact wear monitor assist maintenance programs.
Flexible Communications
Serial and Ethernet communications provide complete integra
tion. IEC 61850 communications offer high-speed, relay-to-relay
information exchange. Supported protocols include ASCII, binary,
and SEL distributed port switch communications. Built-in web server
provides read-only point of access to view metering, settings,
targets, and SER.
The SEL-387E Relay provides security against system and transformer
conditions that may result in relay misoperation. The fifth-harmonic
element prevents relay misoperation during allowable overexcitation
conditions. Second- and fourth-harmonic elements along with the
dc offset element provide security against inrush currents during
transformer energization. The even harmonic elements offer the
choice between harmonic blocking and harmonic restraint. In the
blocking mode, select either blocking on an independent phase basis
or on a common basis. The second-, fourth-, and fifth-harmonic
thresholds are set independently, and the dc blocking and harmonic
restraint features are independently enabled.
Overcurrent Protection
Each three-phase current input terminal has a total of 11 overcurrent
elements, 9 of which are torque-controllable, providing comprehensive
overcurrent protection on each winding input. For backup overcurrent
protection in ring-bus or breaker-and-a-half configurations, two
combined overcurrent elements operate on the sum of the currents
from windings 1 and 2. The combined currents from two separate
breaker CTs emulate the current as if from a single bushing CT applied
on the transformer.
Volts-Per-Hertz Protection
Overexcitation occurs when the magnetic core of a transformer
becomes saturated. When this happens, higher harmonic frequencies
become more prominent, resulting in overheating and damage.
Overexcitation conditions are detected by a volts-per-hertz element.
Use the relay outputs for alarm or trip functions.
The SEL-387E Relay provides sensitive, instantaneous, definite-time
elements plus a settable composite inverse-time/definite-time
characteristic. The relay also includes one user-defined inverse-time
characteristic programmed with SEL-5806 Curve Designer Software.
The inverse-time element has a percent-travel operating characteristic
similar to that employed by an induction-disk time-overcurrent
element. This characteristic coincides well with the heating effect that
overexcitation has on transformer components
The SEL-387E Relay has three differential elements that use operate
and restraint quantities calculated from the two– or three–winding
input currents. Set the differential elements with either a single- or
dual-slope percentage-restraint differential characteristic, as shown
below.
Restricted Earth Fault (REF) Protection
Enhanced Automation Elements
The REF function compares the directions of neutral current and
winding residual current for sensitive ground fault detection in
grounded–wye or autotransformer–connected windings.
Metering Functions
Voltage inputs combined with measured currents yield key metering
information in the SEL-387E Relay. Measured quantities include:
• Three-phase voltage and current from all inputs
• Three-phase and per-phase MW and MWh
• Three-phase and per-phase MVA
• Three-phase and per-phase MVAR and MVARh
• Frequency, volts-per-hertz, harmonics
• Differential currents
• Station battery—four settable alarm levels
Sequential Events Recorder (SER)
Retrieve time-tagged sequential event messages recorded by the
SEL-387E Relay to analyze the time relationships between assertion
and deassertion of logical elements. Apply the relay with an SEL-2032
Communications Processor to quickly and automatically receive SER
messages from the relay in an efficient binary format.
Advanced SELogic® Control Equations
Logically combine selected relay elements for various control
functions, and assign outputs to logic functions. In addition to
Bo