SEL-T401L Ultra-High-Speed Line Relay
Fast, dependable, and simple
• Apply ultra-high-speed protection based on field-proven SEL
time-domain technology with demonstrated trip times on the order
of 1–5 ms.
• Complement and back up the traveling-wave and incremental-quantity
protection elements and schemes with distance elements, directional
elements, and the other protection functions that you expect in a line
protection system.
• Improve fault-locating results to within a single tower span by using
traveling-wave-based fault-locating methods, and ensure dependability
with impedance-based methods.
• Achieve a balance between flexibility and ease of use in a 3U package
with programmable logic, flexible I/O, and SCADA functionality.
ANSI Numbers/Acronyms and Functions
21 Phase and Ground Distance
TD21 Incremental-Quantity Phase and Ground Distance
27 Undervoltage (Phase, Phase to Phase, and
Positive Sequence)
32 Directional (Phase, Zero Seq., and Negative Seq.)
TD32 Incremental-Quantity Directional
TW32 Traveling-Wave Directional
50 Instantaneous Overcurrent (Phase, Zero Sequence,
and Negative Sequence)
51 Inverse-Time Overcurrent (Phase, Zero Sequence,
and Negative Sequence)
59 Overvoltage (Phase, Phase to Phase, Positive
Sequence, Zero Sequence, and Negative Sequence)
67 Instantaneous and Definite-Time Directional
Overcurrent (Phase, Zero Seq., and Negative Seq.)
68 Power-Swing Blocking
78 Out-of-Step Tripping
85 RIO SEL Mirrored Bits® I/O With Selectable SEL MB8 or
IEEE C37.94 Encoding
TW87 Traveling-Wave Differential
94 High-Speed Trip-Rated Outputs
POTT Permissive Overreaching Transfer Trip Logic
CBECHO Open-Breaker Echo Logic
WI Weak-Infeed Logic
DCB Directional Comparison Blocking Logic
SOTF Switch-Onto-Fault Logic
DTT Direct Transfer Trip Logic (Intertripping)
LOP Loss-of-Potential Logic
OP Open-Pole Detection Logic
LE Load Encroachment Logic
DFR Digital Fault Recorder
SER Sequential Events Recorder
FL Fault Locator
LM Line Monitor
LGC seLoGiC® Equations
MET Metering
ARC Adaptive Autoreclose Cancel Logic
HMI Local Operator Interface
DNP3 Distributed Network Protocol 3.0 (Ethernet)
LB Local Control Bits (Operated Through
Front-Panel HMI)
RB Remote Control Bits (Operated Through DNP3
and SEL Fast Operate Protocols)
FTP File Transfer Protocol
FTDV Fast Time-Domain Values
EMI Electromagnetic Interference Monitoring for
Traveling-Wave Functions
TEST Event Playback and Traveling-Wave Test Mode
Key Features
Unparalleled Fault-Locating Technology
Ultra-High-Speed Protection
Using field-proven traveling-wave and incremental-quantity
technologies pioneered in the SEL-T400L Time-Domain
Line Protection, the SEL-T401L delivers industry-leading
operating speed. Sampling line and voltage currents at
1 MHz, processing data every microsecond, using high
speed protection signaling, and tripping with solid-state
trip-rated outputs, the SEL-T401L securely trips in as fast
as 1 ms. Faster fault clearing improves public and utility
personnel safety, widens transient stability margins, limits
equipment wear, improves power quality, and confines
property damage.
The SEL-T401L offers the complete suite of Main 1 and
Main 2 protection functions that you expect in a line
protection system. Its high-performance distance
protection with five zones of phase and ground distance
elements, individually selectable as either mho or
quadrilateral, provide subcycle operating times. The
SEL-T401L also has dependable protection and supervisory
functions, including sensitive directional, switch-onto-fault,
overcurrent, over- and undervoltage, load encroachment,
out-of-step tripping, and power-swing blocking. You can
apply the SEL-T401L on its own or as part of a redundant
protection system with other SEL relays without concerns
for common-mode failures.
Reset the complexity of your line protection applications
with the simple and robust protection philosophies and
considerably lower setting count of the SEL-T401L. It is
available in a 3U chassis, making it a great option when
replacing relays. Gain efficiency by using common SEL
configuration and integration tools, and benefit from
strong diversity in hardware, software, and protection
operating principles.
The SEL-T401L provides state-of-the-art fault locating
based on robust traveling-wave technology. The relay
includes single- and double-ended traveling-wave-based
fault-locating methods that are accurate to within a
single tower span. It also includes single- and double
ended impedance-based methods. The combination
of single-ended and double-ended methods, as well as
traveling-wave-based and impedance-based methods,
provides the best accuracy and dependability for any
combination of operating conditions and fault types. Using
the detailed fault location results, you can confidently
dispatch crews directly to the tower nearest to the fault,
reducing the outage time and maintenance expenses.
Combining the SEL-T401L high-speed double-ended
fault-locating technology and built-in adaptive location
dependent autoreclose cancel logic allows selective
reclosing on the overhead portion of hybrid lines and
inhibits reclosing on cable portions, protecting the cable
from additional insulation damage.
You can use the line-monitoring function in the SEL-T401L
for condition-based line maintenance. This feature helps to
prevent faults and to discover weak spots along the line.
High-Fidelity Transient Recording
The SEL-T401L measures and records line currents
and voltages with high-fidelity (1 MHz, 18-bit) sampling,
offering an enhanced understanding of the events on your
power system. This allows you to analyze high-frequency
transients, such as traveling waves from faults, switching
events, breaker restrikes, and self-extinguishing faults.