KEY FEATURES AND BENEFITS

• From the vibro-meter ® product line

• Power supply for VM600Mk2/ VM600

ABE04x 19 ″ system racks with a height of 6U

• Input: AC-input and DC-input versions

• Outputs: +5 VDC and ±12 VDC

• Output over-voltage, short-circuit and

overload protection

• Status indicators

• High-power, high-performance, high

efficiency

• Minimal derating within the operating

temperature range

APPLICATIONS

• VM600Mk2/ VM600 machinery protection and/

or condition monitoring systems

• One RPS6U rack power supply powers a full

rack of modules (cards)

• Two RPS6U rack power supplies enable rack

power supply redundancy

DESCRIPTION

The VM600Mk2/ VM600 RPS6U rack power supplies

are designed for use in the VM600Mk2/ VM600

series of machinery protection systems and

condition and performance monitoring systems,

from Meggitt’s vibro-meter ® product line.

A VM600Mk2/ VM600 RPS6U rack power supply is

installed in the front of a VM600Mk2/ VM600 ABE04x

system rack (19 ″ system racks with a standard

height of 6U) and connects via two high-current

connectors to the VME bus of the rack’s

backplane. The RPS6U power supply provides

+5 VDC and ±12 VDC to the rack itself and all

installed modules (cards) in the rack via the rack’s

backplane

DESCRIPTION (continued)

Either one or two VM600Mk2/ VM600 RPS6U rack

power supplies can be installed in a VM600Mk2/

VM600 ABE04x system rack. A rack with one

RPS6U power supply (330 W version) supports the

power requirements for a full rack of modules

(cards) in applications with operating

temperatures up to 50 °C (122 °F).

Alternatively, a rack can have two RPS6U power

supplies installed in order to either support rack

power supply redundancy or in order to supply

power to the modules (cards) non-redundantly

over a wider range of environmental conditions.

A VM600Mk2/ VM600 ABE04x system rack with two

RPS6U power supplies installed can operate

redundantly (that is, with rack power supply

redundancy) for a full rack of modules (cards).

This means that if one RPS6U fails, the other will

provide 100 % of the rack’s power requirement so

that the rack will continue to operate, thereby

increasing the availability of the machinery

monitoring system.

Note: This is known as a redundant RPS6U rack

power supply configuration.

A VM600Mk2/ VM600 ABE04x system rack with two

RPS6U power supplies installed can also operate

non-redundantly (that is, without rack power

supply redundancy). Typically, this is only

necessary for a full rack of modules (cards) in

applications with operating temperatures above

50 °C (122 °F), where RPS6U output power derating

is required.

Note: Even though two RPS6U rack power supplies

are installed in the rack, this is not a redundant

RPS6U rack power supply configuration.

The number and type of RPS6U power supplies

installed in a VM600Mk2/ VM600 ABE04x system

rack, together with the number of modules

(cards) installed and the environmental

conditions, helps determine the mode of

operation of the RPS6U power supplies as either

redundant or non-redundant. See also Ordering

information on page 16.

Different versions of the RPS6U rack power supply

enable a VM600Mk2/ VM600 ABE04x system rack

to be powered using external AC and/or DC

mains supplies. All RPS6U power supplies support a

wide input voltage range.

A power supply check relay, available on the

associated rear panel at the rear of a VM600Mk2/

VM600 ABE04x system rack, is used to indicate

that the RPS6U power supplies are operating

normally. Refer to the VM600Mk2/ VM600 ABE04x

system rack data sheet for further information.

In applications where the VM600Mk2/ VM600

ABE04x system rack is powered by an AC mains

supply, a VM600Mk2/ VM600 ASPS auxiliary sensor

power supply can also be included in the rack.

The ASPS provides +24 VDC outputs which can be

used by external sensor/measurement chain

hardware such as front-end sensors, signal

conditioners and galvanic separation units.

For further information, contact your local

Meggitt representative



  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-MeterI/O Relay expansion RLC16 Mk2 600-045
  • Vibro-MeterI/O Relay expansion RLC16 Mk2 600-045
  • Vibro-MeterI/O interface card IOCN Mk2 600-051
  • Vibro-Meter CPU controller   CPUM Mk2   600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-113 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-113 Protective Measurement Card
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK PICMG Single Board Computers NuPRO-900A
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cableles
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform