S+ Control & I/O Update Presentation Outline
Harmony Rack Update & Evolution
SD Series Hardware
IEB800 Infi-Net to Ethernet Bridge
New Developments Coming Soon…
S+ Engineering Update
Latest Version of S+ Operations
What has Changed? Life Cycle Commitment
§ Previous Support commitment Increased from 2025 to indefinitely
Active investment
New features and functions at all levels of the system
Introduction of Symphony Plus Product Name
S+ Control & I/O Update Upgrading to Latest Rack Hardware
Power Supplies Harmony Power Supply - MPSIII
§ Multi-Voltage DC Power System § System and Field Power § 2N and N+1 Configuration § System Monitoring § “Slide-in” Design § Evolution for Network 90, MPS I (PMU), and MPS II Supplies
S+ Control & I/O Update Upgrading PCU Communications
Symphony Plus
Communications
§ Ethernet interface to INFI-Net used by: § Composer 5.1 and Higher § Harmony OPC § Harmony Connect (800xA Process Portal v. 5.1A) § S+ Operations § PPB, Conductor NT* § Security Modes § Basic (Twofish) [Default] § 128 –bit block cipher § Advanced (TLS1/SSL3) § 256-bit encryption § Supports up to 30,000 tags (Ethernet)
S+ Control & I/O Update
Upgrading to ICI800 Ethernet CIUs
Symphony Plus Control & I/O BRC410
Performance increase depends on specific function blocks used, but in general performance of latest module (BRC410) compared with older modules: § ~ 10x vs. MFP01/02/11/12 § ~ 4x vs. BRC100/200 § Enhanced On-Line Configuration provided by BRC410 § BRC410 also provides ModBus TCP § BRC410 support 30,000 block addresses § Infi90 Modulebus support* § Downloadable firmware
S+ Control & I/O Update
Upgrading to S+ Rack Modules
q Harmony Rack Modules q Grey Front Plates q Module Nomenclatures: IMxxxx or INxxxx q Build to Order, longer lead q S+ Rack Modules q White Front Plates q Module Nomenclatures: SPxxxx q Original Price of Grey Modules q Std Factory Lead Time
Symphony Harmony
Comprehensive I/O system
§ Modular to meet varying I/O requirements § Local and remote I/O options § Rack and DIN I/O options § I/O Types § Analog Input § Analog Output § Pulse Input § Digital Input § Digital Output § Turbine Control § SOE timestamp resolution of +/- 1 msec across the entire Harmony system
Harmony I/O options
Expanding with S800 I/O
§ S800 I/O is configured using Composer and standard function codes § BRC simultaneously supports Harmony Rack & S800 I/O § Each IOR-800 supports up to 7 clusters § Each cluster modem supports up to 12 S800 I/O modules
S+ Control & I/O Update
BRC410 Bridge Controller and Gateway
H-Net to Enhanced HN800
Symphony Plus SD Controller
Harmony Control & Communications on a DIN-Rail
HPC800 Harmony Process Controller
PNI800 Plant Network Interface
§ DIN-Rail CIU for Symphony Plus § 1-PNI800 required for each HMI Server: § S+ Operations Server § Harmony RTDS of 800xA PPA § 1-PNI800 can be shared by up to 10 Composer Client Workstations § Composer Communications Server for PN800 Plant Network § PNI800 supports PN800 line redundancy § Connects to both Ethernet lines
SD Series Control & I/O Architectural Comparison
Symphony Plus PDP800: Profibus DP Master for Harmony
PDP800 Profibus Master Module
Symphony Plus
HAI805 & HAO805: HART AI & AO Modules
Address:Xiamen City, Fujian Province, China
TELL:
E-MAIL:gedcs868@gmail.com