DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ABB Procontic Progamming System 907 PC 331 Programming and Test Software

From:ABB | Author:LIAO | Time :2025-08-28 | 517 Browse: | 🔊 Click to read aloud ❚❚ | Share:

– repeat

– according to segment plan

– according to connection

element

– according to unassigned

terminal

● Search and replace

● Insert

● Delete

ONLINE functions

Numerous ONLINE functions support the user during the

commissioning phase, e.g.:

● Status display in – function block diagram

– ladder diagram

– instruction list

– variable list

● Program – transfer

– start

– abort

– stop

– continuation

– status

● Single cycle on/off

● Breakpoint – setting

– display

– deletion

● Triggering – time

– variable

● Overwriting

● Jogging

● Forcing

● Modification of – time and counter setpoints

– variable addresses

– operators

– operand identifiers

– program parts to a limited

extent

Moreover, selected variables can be combined in ONLINE lists and their statuses can be displayed.

Program documentation

Automatic program documentation embraces the following printed lists:

● function block diagram

● instruction list

● connection element library

● logic plan diagram

● ladder diagram

● variable list

● cross–reference list

● comment list

● ONLINE list

● text page

● data area

● modularization list

● total variable list

● total reference list

● system configuration

Outputs can be adapted to any printer.

Print format editor

A special print format editor allows you to add an individual header and footer to the respective lists. Specific data

can also be included automatically in this header or footer,

e.g. name of the project file, date and time

Extended IL

working aid

Input Function

ONLINE commands

<F4> ONLINE on/off

<Alt>

–1 Translate and send program changes

(ONLINE off only)

<Alt>

2 Send program changes

<Alt>

3 Send program

<Alt>

–4 Compare program

<Alt>

–6 Send constants

<Alt>

–7 Compare constants

<Alt>

–8 Reactivate old program

<Alt>

S Start program

<Alt>

–A Abort program

<Alt>

H Stop program

<Alt>

C Continue program

<Alt>

O Switch on ONLINE list with ONLINE ON

<V> Return to ’Display variable status’

<T> Status trigger to variable

<Alt>

M Status trigger to time

<0> (zero) Freeze status on screen

<A> Status of selected variables on/off

<5> Collect for status of selected variables

<6> Save status to ONLINE list

<Z> Single cycle on/off

<S> Single step on/off

<G> Jog

<O> ONLINE list editor

<1> Collect for ONLINE list

<B> Set breakpoint singly

<Alt>

B Delete breakpoint singly

<W> Set all breakpoints

<Alt>

W Delete all breakpoints

<2> Collect for breakpoint list

<Q> Display breakpoint

<P> Following the breakpoint on/off

<L> Enter the breakpoint list

<4> Collect for overwriting

<U> Overwrite singly

<R> Overwrite all

<3> Collect for forcing

<F> Force singly

<Alt>

F Disable force singly

<E> Force all

<Alt>

E Disable force all

<Alt>

D Read force values into ONLINE list

<X> Toggle bit/word

<D> Select value display dec/hex/oct;

menu is displayed

<F9> Toggle variable display,

absolute or symbolic

<Ctrl>

P Display variable, display variable with symbol and long text, no modification possible

FBD

working aid

Input Function

ONLINE commands

<F4> ONLINE on/off

<Alt>

–1 Translate and send program changes

(ONLINE off only)

<Alt>

2 Send program changes

<Alt>

3 Send program

<Alt>

–4 Compare program

<Alt>

–6 Send constants

<Alt>

–7 Compare constants

<Alt>

–8 Reactivate old program

<Alt>

S Start program

<Alt>

–A Abort program

<Alt>

H Stop program

<Alt>

C Continue program

<Alt>

O Switch on ONLINE list with ONLINE ON

<V> Return to ’Display variable status’

<T> Status trigger to variable

<Alt>

M Status trigger to time

<0> (zero) Freeze status on screen

<A> Status of selected variables on/off

<5> Collect for status of selected variables

<6> Save status to ONLINE list

<Z> Single cycle on/off

<S> Single step on/off

<G> Jog

<O> ONLINE list editor

<1> Collect for ONLINE list

<B> Set breakpoint singly

<Alt>

B Delete breakpoint singly

<W> Set all breakpoints

<Alt>

W Delete all breakpoints

<2> Collect for breakpoint list

<Q> Display breakpoint

<P> Following the breakpoint on/off

<L> Enter the breakpoint list

<4> Collect for overwriting

<U> Overwrite singly

<R> Overwrite all

<3> Collect for forcing

<F> Force singly

<Alt>

F Disable force singly

<E> Force all

<Alt>

E Disable force all

<Alt>

D Read force values into ONLINE list

<X> Toggle bit/word

<D> Select value display dec/hex/oct;

menu is displayed

<F9> Toggle variable display,

absolute or symbolic

<Ctrl>

P Display variable, display variable with symbol and long text, no modification possible

Variable editor 

working aid

Input Function

ONLINE commands

<F4> ONLINE on/off

<Alt>–S Start program

<Alt>–A Abort program

<Alt>–H Stop program

<Alt>–C Continue program

<Alt>–O Switch on ONLINE list with ONLINE ON

<V> Return to ’Display variable status’

<T> Status trigger to variable

<Alt>–M Status trigger to time

<0> (zero) Freeze status on screen

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card