DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

parkerRack power supply unit

From:parker | Author:LIAO | Time :2025-08-21 | 632 Browse: | 🔊 Click to read aloud ❚❚ | Share:

» From the Vibro-Meter ® product line

» Power supply unit for VM600 system rack (6U)

» High performance

» Wide input voltage range

» Over-voltage protection

» Continuous short-circuit proof

» Minimal derating within the operating

temperature range

» 6U height

» Compact design

» Fully VME compatible

» Conforms to EC standards for EMC

» Up to two RPS6U rack power supply units can be 

installed in a VM600 system rack (ABE04x)

Rack power supply unit (RPS6U)

for a VM600 system rack (ABE04x)

DESCRIPTION

The RPS6U rack power supply units are designed for 

use in the VM600 series of machinery protection 

systems and condition and performance monitoring 

systems, from Meggitt Sensing Systems’ Vibro-Meter 

product line.

The RPS6U is installed in the front of a VM600 

system rack (ABE04x) with a standard height of 6U 

and connects directly to the rack backplane via two 

connectors. The power supply provides +5 VDC and 

±12 VDC power to all cards in the rack via the rack 

backplane.

One or two RPS6U power supplies can be installed in 

a VM600 system rack. A rack can have two RPS6U 

units installed for different reasons: to supply power to 

a rack with many cards installed, non-redundantly, or 

to supply power to a rack with fewer cards installed, 

redundantly. Typically, the cutoff point is when nine 

rack slots or fewer are used

Rack power supply unit

RPS6U

2 / 15 © Meggitt SA / 268-011 / Version 9 / 23.04.2015 / E

DESCRIPTION (continued)

When a VM600 system rack is operating with two 

RPS6U units for power supply redundancy, if one 

RPS6U fails, the other will provide 100% of the power 

requirement and the rack will continue to operate, 

thereby increasing the availability of the machinery 

monitoring system.

Various versions of the RPS6U exist, allowing a rack 

to be powered from external AC or DC mains supplies 

with a range of supply voltages.

A power supply check relay, available at the rear of a 

VM600 rack, indicates that the power supplies are 

operating normally. Refer to the ABE040 and ABE042 

VM600 system rack and ABE056 VM600 slimline 

rack data sheets for additional information on power 

supply check relays.

In applications where the VM600 rack is powered by 

an AC mains supply, an auxiliary sensor power supply 

(ASPS) can also be included in the rack. The ASPS 

provides +24 VDC outputs which can be used by 

external hardware such as front-end transducers, 

signal conditioners and galvanic separation units.

For specific applications, contact your nearest Meggitt 

Sensing Systems representative.

SPECIFICATIONS

Power supply

Input

Input voltage range (Vi

 nom.) : See Ordering information on page 12

Mains frequency variations : See Ordering information on page 12

Efficiency : See Ordering information on page 12

Output

Nominal output (Vo nom. / Io max.)

• DC output 1 : +5 VDC / +35 A

• DC output 2 : +12 VDC / +6 A

• DC output 3 : −12 VDC / −2 A

Stability of output voltage Uo

under full load conditions

: ≤ ±0.2%

Ripple (bandwidth 20 MHz) : ≤ 50 mVpp

Output current limitation : 35 A (electronic current limiter)

Output overvoltage protection : 5.9 to 6.7 V (factory set)

Power derating : 1%/°C from 60 to 70°C

Power

Rated power : 300 W

Rated supply voltage : See Ordering information on page 12

Environmental

According to IEC 60068-2 recommendations

Operating temperature range : −25 to +65°C (−13 to +149°F)

Storage temperature range : −40 to +85°C (−40 to +185°F)

Humidity : ≤ 95% non-condensing

Vibration : 10 to 2000 Hz, 5 g, 2 h in each direction

Shock : 100 g, 6 ms, half-sine pulse

Physical

Dimensions : 6 U / 12 HP (TE) x 187 mm

Weight (approx.) : 2.1 kg (4.63 lb) 

Safety

Applicable safety standards : UL 1950, CSA 22.2#234, IEC 950, EN 60950

Marking : See Ordering information on page 12

TOLERANCE TO MICRO-INTERRUPTIONS IN THE SUPPLY INPUT

The table below shows the maximum permissible duration of a power cut which will not cause MPC4 cards to be reset. 

This value depends on the number of MPC4 cards and RPS6U units installed in the VM600 rack.

Number of RPS6U power supplies in VM600 system rack

Number of MPC4 cards in

VM600 system rack

1 unit 2 units

2 cards 190 ms 250 ms

12 cards 10 ms 20 ms

S

ORDERING INFORMATION (continued)

Rear panels

To order please specify the type (Rear panel), designation and ordering number from the table below

(see also the drawings (a) to (k) in Associated rear panels on pages 4 to 9)

Drawing Designation Ordering number

(a)

One DC input with screw-terminal connector that provides a common input to the

RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F200.

200-582-920-NHh

(b)

Two DC inputs with screw-terminal connectors that provide individual inputs to the

RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F930.

200-582-993-NHh

(c)

One DC input with screw-terminal connector that provides a common input to the

RPS6U power supplies. Also provides a special earth terminal (identified as M.A.L.T.).

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F220.

200-582-922-NHh

(d)

Two DC inputs with screw-terminal connectors that provide a common input to the

RPS6U power supplies.

Supports redundant external power-supply systems.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F900.

200-582-990-NHh

(e)

One AC input (120/230 VAC) with mains socket and on/off switch that provides a common 

input to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F100.

200-582-910-NHh

(f)

One AC input (120/230 VAC) with screw-terminal connector, on/off switch and rear-panel fuses 

that provides a common input to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F110.

200-582-911-NHh

(g)

One AC input (120/230 VAC) with screw-terminal connector and rear-panel fuses that provides 

a common input to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F120.

200-582-912-NHh

(h)

Two AC inputs (120 VAC only) with mains sockets and on/off switches that provide a common 

input to the RPS6U power supplies.

Supports redundant external power-supply systems.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F620.

200-582-962-NHh

(i)

Two AC inputs (120/230 VAC) with mains sockets and on/off switches that provide individual 

inputs to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F630.

200-582-963-NHh

(j)

Two AC inputs (230 VAC only) with mains sockets and on/off switches that provide a common 

input to the RPS6U power supplies.

Supports redundant external power-supply systems.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F600.

200-582-960-NHh

(k)

Two AC inputs (120/230 VAC) with screw-terminal connectors, on/off switches and rear-panel 

fuses that provide individual inputs to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F150.

200-582-915-NHh

(l)

Two AC inputs (120/230 VAC) with screw-terminal connectors and rear-panel fuses that 

provide individual inputs to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F160.

200-582-916-NHh

(m)

One AC input (120/230 VAC) with mains socket and on/off switch and one DC input with screwterminal connector that provide individual inputs to the RPS6U power supplies.

This rear panel is equivalent to Rear panel for RPS6U power supply order option code F700.

200-582-970-NHh

Rack power supply unit

RPS6U

14 / 15 © Meggitt SA / 268-011 / Version 9 / 23.04.2015 / E

Notes

All AC input rear panels are supplied with a mains power supply lead (no lead is supplied for the DC input versions). See Mains power 

supply leads (power cords) on page 14.

AC input rear panels with mains sockets have an IEC type C14 connector (IEC 60320) that mates with the plug (type C13) used by the 

supplied mains power supply leads.

Rear panels with one input – (a), (b), (c), (d), (e), (f) and (g) – are 2 slots wide / 8 HP (TE).

Most rear panels with two inputs – (h), (i), (j), (k) and (l) – are 4 slots wide / 16 HP (TE).

However, the rear panel with AC and DC inputs – (m) is 2 slots wide / 8 HP (TE).

(The width of 19″ rack is measured in horizontal pitch (HP) units of 5.08 mm (0.2″), also known as standard width (TE) units. For the 

ABE04x rack, a one slot wide (one card position) blank panel corresponds to 4 HP (TE), a two slot wide blank panel corresponds to 8 HP (TE) 

and a four slot wide blank panel corresponds to 16 HP (TE).)

Rear panels with two input connectors that provide a common input to the RPS6U power supplies – (d), (h) and (j) – installed in the rack can 

be used with a redundant external power-supply system.

For additional information on the Rear panel for RPS6U power supply order option codes (Fxxx), refer to the ABE040 and ABE042 VM600 

system rack and ABE056 VM600 slimline rack data sheets.

For the Ordering number:

“NHh” represents the hardware version.

“N” is either “0” for a rear panel according to (and marked) CE low voltage directive or “2” for a rear panel according to (and marked) CCSAUS.

“H” increments are for major modifications that can affect product interchangeability.

“h” increments are for minor modifications that have no effect on interchangeability

Mains power supply leads (power cords)

To order please specify the type (Mains power supply lead), designation and ordering number from the table below

Designation Ordering number

None – no mains cable.

This rear panel is equivalent to Mains power supply lead (power cord) order option code H00. ---

No plug – flying lead with wire-end ferrules.

This rear panel is equivalent to Mains power supply lead (power cord) order option code H01. 957.18.13.0020

J plug as per SEV 1011 (Switzerland).

This rear panel is equivalent to Mains power supply lead (power cord) order option code HCH. 957.18.13.0021

E+F plug as per CEE7/VII (Europe, Russia, Ukraine).

This rear panel is equivalent to Mains power supply lead (power cord) order option code HEU. 957.18.13.0022

G plug as per BS 1363 (UK, Hong Kong, Malaysia, Singapore).

This rear panel is equivalent to Mains power supply lead (power cord) order option code HUK. 957.18.13.0023

B plug as per JIS 8303 (Japan).

This rear panel is equivalent to Mains power supply lead (power cord) order option code HJP. 957.18.13.0024

B plug as per NEMA 5-15 (United States, Canada).

This rear panel is equivalent to Mains power supply lead (power cord) order option code HUS. 957.18.13.0025

Notes

The mains cables (power cords) are for the AC input version of the RPS6U power supply. No cables are available for the DC input versions.

Rear panels with two AC inputs for independent mains supplies (ordering numbers: 200-582-96x-NHh) require two mains cables.

For additional information on the Mains power supply lead (power cord) order option codes (Hxx), refer to the ABE040 and ABE042 VM600 

system rack and ABE056 VM600 slimline rack data sheets.

Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, 

defence and energy markets.

Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 

under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are 

integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned 

brands, from a single supply base.

The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of 

vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and 

innovative software for aerospace and land-based turbo-machinery.

All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole 

purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. 

Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in 

writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in 

good faith, are not binding on Meggitt SA.

Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems 

publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We 

reserve the right to alter any part of this publication without prior notice.

In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12 345.678 90.


  • Jaquet Relay card (Auxiliary module) FTV 3090 377Z-03985
  • Jaquet Trip Chain Control card FTBU 3034 377Z-05030
  • Jaquet with input card -E04 FTFU 3024 -E04 377Z-05855
  • Jaquet with input card -E03 FTFU 3024- E03 377Z-03983
  • Jaquet FTFU 3024- E02 377Z-03982 with input card -E02
  • Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01
  • Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch
  • Hirschmann BELDEN EAGLE30-04022O6TT999SCCV9HSE3F
  • Hirschmann MM3-2FXS2/2TX MICE Media Module
  • Hirschmann RS20-1600M2M2SDAPHC08.0.05 Industrial Managed Switch
  • Hirschmann OZD Profi 12M G12-1300 PRO Fieldbus Repeater
  • Hirschmann SPIDER 4TX/1FX-ST EEC Industrial Ethernet Switch
  • Hirschmann MM2-2FXM3/2TX1 MICE Media Module
  • Hirschmann RS20-2400M2M2SDAPHC09.0.14 Industrial Switch
  • Hirschmann RS20-0400M2M2SDAEHC07.1.05 OpenRail Switch
  • Hirschmann OZD Profi 12M G12-EEC Fieldbus Repeater
  • HIRSCHMANN MDA422-1/2-3.5c-23/46 sensor
  • Hirschmann RS30-2402T1T1SDAUHC Managed Industrial Switch
  • Hirschmann OZD GENIUS G12 Industrial Switche
  • Hirschmann OZD 485 G12-1300 PRO Fieldbus Repeater
  • Hirschmann MM2-2FXM2 MICE Media Module
  • Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch
  • Hirschmann MS20-0800SAAEHH04.2.04 MICE Switch
  • Hirschmann SPIDER 4TX/1FX EEC Unmanaged Industrial Switch
  • HIRSCHMANN MS4128-L3P EEC Managed Industrial Ethernet Switch
  • HIRSCHMANN RS20-0400M2T1SDAPHC08.0.01 Managed Switch
  • ETEL EA-S0M-400-40/80A-0000-00 AccurET Modular Power Supply
  • ETEL EA-B0I-0-0-0000-00 Backplane Interface Board
  • ETEL EA-P2M-400-15/40A-0100-00 Position Controller
  • ETEL EA-P2M-400-15/40A-0000-00 Position Controller
  • ETEL EA-P2M-400-10/20A-0100-01 Position Controller
  • ETEL EA-P2M-400-10/20A-0000-01 Position Controller
  • ETEL EA-P2M-400-5/10A-0100-01 Position Controller
  • ETEL EA-P2M-048-2.5/5A-0000-01 Modular Position Controller
  • ETEL EA-S0M-300-40/80A-0000-00 Power Supply Module
  • ETEL EA-P2M-300-07/15A-0100-01 Position Controller
  • ETEL EA-P2M-300-07/15A-0000-01: Modular Position Controller
  • ETEL EA-P2M-300-4/7.5A-0100-01 Overview
  • Basler Electric MOC2. Motor Operated Potentiometer
  • Basler Electric BE1-11 RTD Module, Resistance Temperature Detector
  • Basler Electric RDP-110C, Remote Display Panel
  • Basler Electric VRM-2020. Voltage Regulation Module
  • Basler Electric IDP-1500. Interactive Display Panel
  • Basler Electric AEM-2020. Analog Expansion Module
  • Basler Electric IDP-2020. Interactive Display Panel
  • Basler Electric CEM-2020. Contact Expansion Module
  • Basler Electric CEM-125. Contact Expansion Module
  • Basler Electric BE2000E, Digital Voltage Regulator
  • Basler Electric SMC-150. Synchronous Motor Controller
  • Basler Electric AVC125-10. Voltage Regulator
  • Basler Electric BE1-25. Sync-Check Relay
  • Basler Electric DGC-2020ES, Digital Genset Controller
  • ETEL EA-P2M-400-5/10A-0000-01 Position Controller
  • Basler Electric BE1-64F, Ground Fault Relay
  • Basler Electric BE1-79M, Multi Shot Reclosing Relay
  • Basler Electric BE1-81O/U, Digital Frequency Relay
  • Basler Electric BE1-87B, High Impedance Bus Differential Relay
  • Basler Electric BE1-79A, Reclosing Relay
  • Basler Electric BE1-27. BE1-59. BE1-27/59. Voltage Relay
  • Basler Electric SMC-250. Synchronous Motor Controller
  • Basler Electric SGC-250N, Synchronous Generator Controller
  • Basler Electric SGC-250. Synchronous Generator Controller
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric DECS-2100. Digital Excitation Control System
  • Basler Electric DECS-250E, Digital Excitation Control System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric DECS-250. Digital Excitation Control System
  • Basler Electric DECS-450. Digital Excitation Control System
  • Basler Electric DECS-150. Digital Excitation Control System
  • Basler Electric ES-49. Temperature Relay
  • Basler Electric ES-81O/U, ES-81O,ES-81U Overfrequency Relay
  • Basler Electric ES-74V, DC Voltage Sensing Relay
  • Basler Electric ES-27/59. Under/Overvoltage Relay
  • Basler Electric ES-27. Undervoltage Relay
  • Basler Electric ES-25. Sync-Check Relay
  • Basler Electric ES-47, ES-47N Phase Sequence Relay
  • Basler Electric ES-37.ES-37/51 Undercurrent Relay
  • Basler Electric ES-32. Reverse Power Relay
  • Basler Electric ES-59. Overvoltage Relay
  • Basler Electric ES-55. Power Factor Relay
  • Basler Electric DGC-2020HD, Digital Genset Controller
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Schneider GUTOR OC0935 Power Factor Sampling Board
  • Schneider GUTOR OC0922 Analog Signal Isolation Board
  • Schneider GUTOR OC0908 Battery Voltage Detection Board
  • Schneider GUTOR OC0947 Temperature / IGBT Sampling Board
  • Schneider GUTOR OP2601 Communication Expansion Board
  • Schneider Electric GUTOR OP2312 bypass control board
  • Schneider Electric GUTOR OP2130 Cooling Fan Monitoring & Control Board
  • Schneider Electric GUTOR OP2010 Battery Test Board / Battery Management Diagnostic Card
  • Schneider Electric GUTOR OP2552 Three-phase Power Connection Board Assembly
  • Schneider Electric GUTOR OP1922A Parallel Control Board / Load-Sharing Synchronization Module
  • Schneider Electric GUTOR OP6290B Inverter Feedback Acquisition Board / Signal Scaling Module
  • Schneider GUTOR OP6280 Basic Signal Board
  • Schneider Electric GUTOR OP2456 / OP2456B Main control board
  • Schneider Electric GUTOR OP2452 Power Plug-in Panel
  • Schneider Electric GUTOR OP2450 Parallel Communication Board
  • Schneider Electric GUTOR OP2406 Interface Fuse Monitoring Board
  • Schneider Electric GUTOR OC0919 High-Power Semiconductor Module
  • Schneider Electric GUTOR OP6281A System Logic Interface Board
  • Schneider Electric GUTOR OP6285A Power Signal Acquisition Board
  • Schneider Electric GUTOR OP2438 Fan Monitor & Drive Protection Board
  • Schneider Electric GUTOR OP2446 Main Control CPU Board
  • ROLLS-ROYCE CE05-00 Steering Gear Control Module
  • ROLLS-ROYCE MARINE AS-BRATTVAAG WRC1021A CONTROLLER CARD
  • ROLLS ROYCE DECK MACHINERY MPC-300-A7029099 TERMINAL CONTROLLER UNIT
  • ROLLS-ROYCE HELICON THRUSTER CONTROL PANEL LF90S-01-06
  • Rolls-Royce PCC1030C Panel Controller Card
  • Rolls-Royce RRDIO15 Remote Digital Input/Output Module
  • Rolls-Royce TDI-11 Pitch & Direction Indicator Module
  • Rolls-Royce CCN 01 CANman Controller Network Module
  • Rolls-Royce SLIO 01 CANman Controller Network Module
  • Rolls-Royce MPC-210 Winch & Propulsion Control Module
  • Rolls-Royce MTI-144 Engine Control Module
  • Rolls-Royce Tenfjord FB10-002 Steering Gear Module (E-4500-40-1)
  • ROLLS ROYCE MARINE AS CIRCUIT BOARD (PCB) RRAI016
  • Rolls-Royce Marine AS PIP6-1 Marine Controller
  • ROLLS-ROYCE MPC-300 STARTER CONTROL UNIT A7029099
  • Rolls-Royce Data Respons MPCF1-10.4" Maritime Panel Computer
  • ROLLS-ROYCE MARINE OLC-40009 PCB CARD
  • Rolls-Royce Marine Brattvaag WRC1021B Controller Board
  • ROLLS-ROYCE CCN 01 & ROLLS-ROYCE SLIO 02 CANMAN CONTROLLER NETWORK
  • ROLLS-ROYCE ATC-3-A7033172 AQUAMASTER TURNING CONTROLLER
  • ROLLS-ROYCE POSCON V.3 JOYSTICK MODULE 6459
  • Rolls-Royce Marine 389-496-00 Joystick Remote Control Panel 6799-W, 389-996-00
  • Rolls-Royce data respons 10.4'' Panel Computer 98H010A0000I/R10I53S
  • Rolls-Royce H1127.0101 Marine Controller 000068308
  • ​Rolls-Royce CU40-0106-50 Steering Gear Control Panel