» From the Vibro-Meter ® product line
» Power supply unit for VM600 system rack (6U)
» High performance
» Wide input voltage range
» Over-voltage protection
» Continuous short-circuit proof
» Minimal derating within the operating
temperature range
» 6U height
» Compact design
» Fully VME compatible
» Conforms to EC standards for EMC
» Up to two RPS6U rack power supply units can be
installed in a VM600 system rack (ABE04x)
Rack power supply unit (RPS6U)
for a VM600 system rack (ABE04x)
DESCRIPTION
The RPS6U rack power supply units are designed for
use in the VM600 series of machinery protection
systems and condition and performance monitoring
systems, from Meggitt Sensing Systems’ Vibro-Meter
product line.
The RPS6U is installed in the front of a VM600
system rack (ABE04x) with a standard height of 6U
and connects directly to the rack backplane via two
connectors. The power supply provides +5 VDC and
±12 VDC power to all cards in the rack via the rack
backplane.
One or two RPS6U power supplies can be installed in
a VM600 system rack. A rack can have two RPS6U
units installed for different reasons: to supply power to
a rack with many cards installed, non-redundantly, or
to supply power to a rack with fewer cards installed,
redundantly. Typically, the cutoff point is when nine
rack slots or fewer are used
Rack power supply unit
RPS6U
2 / 15 © Meggitt SA / 268-011 / Version 9 / 23.04.2015 / E
DESCRIPTION (continued)
When a VM600 system rack is operating with two
RPS6U units for power supply redundancy, if one
RPS6U fails, the other will provide 100% of the power
requirement and the rack will continue to operate,
thereby increasing the availability of the machinery
monitoring system.
Various versions of the RPS6U exist, allowing a rack
to be powered from external AC or DC mains supplies
with a range of supply voltages.
A power supply check relay, available at the rear of a
VM600 rack, indicates that the power supplies are
operating normally. Refer to the ABE040 and ABE042
VM600 system rack and ABE056 VM600 slimline
rack data sheets for additional information on power
supply check relays.
In applications where the VM600 rack is powered by
an AC mains supply, an auxiliary sensor power supply
(ASPS) can also be included in the rack. The ASPS
provides +24 VDC outputs which can be used by
external hardware such as front-end transducers,
signal conditioners and galvanic separation units.
For specific applications, contact your nearest Meggitt
Sensing Systems representative.
SPECIFICATIONS
Power supply
Input
Input voltage range (Vi
nom.) : See Ordering information on page 12
Mains frequency variations : See Ordering information on page 12
Efficiency : See Ordering information on page 12
Output
Nominal output (Vo nom. / Io max.)
• DC output 1 : +5 VDC / +35 A
• DC output 2 : +12 VDC / +6 A
• DC output 3 : −12 VDC / −2 A
Stability of output voltage Uo
under full load conditions
: ≤ ±0.2%
Ripple (bandwidth 20 MHz) : ≤ 50 mVpp
Output current limitation : 35 A (electronic current limiter)
Output overvoltage protection : 5.9 to 6.7 V (factory set)
Power derating : 1%/°C from 60 to 70°C
Power
Rated power : 300 W
Rated supply voltage : See Ordering information on page 12
Environmental
According to IEC 60068-2 recommendations
Operating temperature range : −25 to +65°C (−13 to +149°F)
Storage temperature range : −40 to +85°C (−40 to +185°F)
Humidity : ≤ 95% non-condensing
Vibration : 10 to 2000 Hz, 5 g, 2 h in each direction
Shock : 100 g, 6 ms, half-sine pulse
Physical
Dimensions : 6 U / 12 HP (TE) x 187 mm
Weight (approx.) : 2.1 kg (4.63 lb)
Safety
Applicable safety standards : UL 1950, CSA 22.2#234, IEC 950, EN 60950
Marking : See Ordering information on page 12
TOLERANCE TO MICRO-INTERRUPTIONS IN THE SUPPLY INPUT
The table below shows the maximum permissible duration of a power cut which will not cause MPC4 cards to be reset.
This value depends on the number of MPC4 cards and RPS6U units installed in the VM600 rack.
Number of RPS6U power supplies in VM600 system rack
Number of MPC4 cards in
VM600 system rack
1 unit 2 units
2 cards 190 ms 250 ms
12 cards 10 ms 20 ms
S
ORDERING INFORMATION (continued)
Rear panels
To order please specify the type (Rear panel), designation and ordering number from the table below
(see also the drawings (a) to (k) in Associated rear panels on pages 4 to 9)
Drawing Designation Ordering number
(a)
One DC input with screw-terminal connector that provides a common input to the
RPS6U power supplies.
This rear panel is equivalent to Rear panel for RPS6U power supply order option code F200.
200-582-920-NHh
(b)
Two DC inputs with screw-terminal connectors that provide individual inputs to the
RPS6U power supplies.
This rear panel is equivalent to Rear panel for RPS6U power supply order option code F930.
200-582-993-NHh
(c)
One DC input with screw-terminal connector that provides a common input to the
RPS6U power supplies. Also provides a special earth terminal (identified as M.A.L.T.).
This rear panel is equivalent to Rear panel for RPS6U power supply order option code F220.