ABB 500SCM01 1MRB150004R0001 1MRB200059/C Signal Regulation and Monitoring Module
The ABB 500SCM01 (Part Number: 1MRB150004R0001 / 1MRB200059/C) is a Signal Conditioning and Monitoring (or Serial Communication/Converter) module specifically designed for the ABB REB500 busbar protection system.
It acts as a specialized interface for handling high-priority synchronization and serial data signals within the protection rack.
Introduction
The 500SCM01 is a critical utility module in the REB500 ecosystem. Its primary role is to provide a clean, isolated interface for auxiliary signals that fall outside the scope of standard binary or analog inputs.
The revision "/C" identifies this as a hardware-optimized version with improved signal filtering and electromagnetic compatibility (EMC), ensuring it can operate reliably in the electrically "noisy" environment of a high-voltage substation.
Technical Parameter Table
| Parameter | Specification |
| Model Number | 500SCM01 |
| Order Code | 1MRB150004R0001 |
| Reference Code | 1MRB200059/C |
| Function | Signal Conversion / Serial Monitoring |
| Power Supply | 5V / 24V DC (via internal backplane) |
| Isolation Voltage | 2.5 kV AC |
| Communication Ports | Serial (RS232/RS485) internal/external links |
| Sampling Support | High-speed synchronization pulse processing |
| Operating Temp | -10°C to +55°C |
| Mounting | 19-inch Subrack (Plug-in) |
Product Advantages and Features
Advanced Signal Conditioning: Filters out high-frequency noise from field wiring, preventing "ghost" signals from reaching the CPU.
Galvanic Isolation: High insulation levels protect the central unit electronics from surges originating in the substation yard.
Precision Timing: Specifically engineered to handle time-synchronization signals (like PPS or IRIG-B) across the internal bus without significant propagation delay.
Hardware Rev /C Stability: Utilizes high-grade capacitors and industrial-strength components for a long service life (typically 20+ years).
Hot-Swap Support: In many configurations, this module can be replaced while the rack is powered (provided the proper bypass procedures are followed).
Application Cases
Distributed Busbar Protection: Used to interface synchronization links between Central Units and peripheral Bay Units.
External Logic Integration: Converting non-standard serial signals from legacy protection relays into data the REB500 bus can interpret.
Redundant Communication: Acts as a secondary data path for system-level diagnostics and monitoring.
Station Clock Interface: Serving as the physical input point for a station’s Master Clock to synchronize all protection event logs.
| ABB | SK616001-A |
| ABB | F362 |
| ABB | DSQC332A |
| ABB | DSQC633 |
| ABB | REF610 |
| ABB | 3BHB005171R0101 |
| ABB | C310/0020/STD |
| ABB | 07KT97H3 |
| ABB | 5SHX1060H0003 |
| ABB | 216AB61 |
| ABB | 216DB61 |
| ABB | NPCT-01C |
| ABB | 5SHY3545L0009 |
| ABB | 3HAC17484-8108 |
| ABB | PFCL201C 10KN |
| ABB | 086345-504 |
| ABB | 086349-002 |
| ABB | 086329-003 |
Installation and Maintenance
Installation
Slot Alignment: The 500SCM01 must be placed in the designated slot for auxiliary/serial modules. Do not force the module; ensure the backplane pins are perfectly aligned.
ESD Safety: Always wear a grounded anti-static wrist strap. Touching the PCB components directly can cause latent damage to the CMOS chips.
Firmware Matching: Ensure the hardware revision /C is compatible with your current HMI500 configuration version.
Maintenance
Log Analysis: Periodically check the REB500 "Internal Communication" logs. Occasional retries can indicate that the SCM module is struggling with signal noise or cable degradation.
Contact Cleaning: During major maintenance cycles, inspect the backplane connector for oxidation. If necessary, use a non-residue contact cleaner.
Thermal Check: Since this module is often sandwiched between the CPU and Power Supply, ensure the rack fans are moving air effectively across the SCM surface.
Other Models in the Same Series
Model Description
500CPU05 Central Processing Unit (The "Brain")
500BIO01 Binary Input/Output Interface
500TRM02 Transformer Input Module (Analog signals)
500CIM05 Ethernet Communication Interface
500PSM01 Power Supply Module
Peer Tip: If you are troubleshooting a "Time Sync Lost" alarm in an REB500 system, the 500SCM01 is often the hardware interface responsible.
Check the LEDs on this module first—a steady red "Fail" light usually indicates an internal hardware fault rather than a cabling issue.