DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
ABB  500SCM01 1MRB150004R0001 1MRB200059/C  Signal Regulation and Monitoring Module
❤ Add to collection

ABB 500SCM01 1MRB150004R0001 1MRB200059/C Signal Regulation and Monitoring Module

ABB  500SCM01 1MRB150004R0001 1MRB200059/C  Signal Regulation and Monitoring Module

85230.00
¥78560.00
¥78560.00
¥78560.00
Weight:3.000KG
Description

ABB  500SCM01 1MRB150004R0001 1MRB200059/C  Signal Regulation and Monitoring Module


The ABB 500SCM01 (Part Number: 1MRB150004R0001 / 1MRB200059/C) is a Signal Conditioning and Monitoring (or Serial Communication/Converter) module specifically designed for the ABB REB500 busbar protection system. 

It acts as a specialized interface for handling high-priority synchronization and serial data signals within the protection rack.

Introduction

The 500SCM01 is a critical utility module in the REB500 ecosystem. Its primary role is to provide a clean, isolated interface for auxiliary signals that fall outside the scope of standard binary or analog inputs. 

The revision "/C" identifies this as a hardware-optimized version with improved signal filtering and electromagnetic compatibility (EMC), ensuring it can operate reliably in the electrically "noisy" environment of a high-voltage substation.

Technical Parameter Table

ParameterSpecification
Model Number500SCM01
Order Code1MRB150004R0001
Reference Code1MRB200059/C
FunctionSignal Conversion / Serial Monitoring
Power Supply5V / 24V DC (via internal backplane)
Isolation Voltage2.5 kV AC
Communication PortsSerial (RS232/RS485) internal/external links
Sampling SupportHigh-speed synchronization pulse processing
Operating Temp-10°C to +55°C
Mounting19-inch Subrack (Plug-in)

Product Advantages and Features

Advanced Signal Conditioning: Filters out high-frequency noise from field wiring, preventing "ghost" signals from reaching the CPU.

Galvanic Isolation: High insulation levels protect the central unit electronics from surges originating in the substation yard.

Precision Timing: Specifically engineered to handle time-synchronization signals (like PPS or IRIG-B) across the internal bus without significant propagation delay.

Hardware Rev /C Stability: Utilizes high-grade capacitors and industrial-strength components for a long service life (typically 20+ years).

Hot-Swap Support: In many configurations, this module can be replaced while the rack is powered (provided the proper bypass procedures are followed).

Application Cases

Distributed Busbar Protection: Used to interface synchronization links between Central Units and peripheral Bay Units.

External Logic Integration: Converting non-standard serial signals from legacy protection relays into data the REB500 bus can interpret.

Redundant Communication: Acts as a secondary data path for system-level diagnostics and monitoring.

Station Clock Interface: Serving as the physical input point for a station’s Master Clock to synchronize all protection event logs.

ABBSK616001-A
ABBF362
ABBDSQC332A
ABBDSQC633
ABBREF610
ABB3BHB005171R0101
ABBC310/0020/STD
ABB07KT97H3
ABB5SHX1060H0003
ABB216AB61
ABB216DB61
ABBNPCT-01C
ABB5SHY3545L0009
ABB3HAC17484-8108
ABBPFCL201C   10KN
ABB086345-504
ABB086349-002
ABB086329-003

Installation and Maintenance

Installation

Slot Alignment: The 500SCM01 must be placed in the designated slot for auxiliary/serial modules. Do not force the module; ensure the backplane pins are perfectly aligned.

ESD Safety: Always wear a grounded anti-static wrist strap. Touching the PCB components directly can cause latent damage to the CMOS chips.

Firmware Matching: Ensure the hardware revision /C is compatible with your current HMI500 configuration version.

Maintenance

Log Analysis: Periodically check the REB500 "Internal Communication" logs. Occasional retries can indicate that the SCM module is struggling with signal noise or cable degradation.

Contact Cleaning: During major maintenance cycles, inspect the backplane connector for oxidation. If necessary, use a non-residue contact cleaner.

Thermal Check: Since this module is often sandwiched between the CPU and Power Supply, ensure the rack fans are moving air effectively across the SCM surface.

Other Models in the Same Series

Model    Description

500CPU05    Central Processing Unit (The "Brain")

500BIO01    Binary Input/Output Interface

500TRM02    Transformer Input Module (Analog signals)

500CIM05    Ethernet Communication Interface

500PSM01    Power Supply Module

Peer Tip: If you are troubleshooting a "Time Sync Lost" alarm in an REB500 system, the 500SCM01 is often the hardware interface responsible.

 Check the LEDs on this module first—a steady red "Fail" light usually indicates an internal hardware fault rather than a cabling issue.


  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200