723PLUS Digital Control

9906-619. 9906-620. 9906-700

This manual describes the Woodward 723PLUS Digital Control hardware,

9906-619 (low voltage), 9906-620 (high voltage), and 9906-700 (modified

actuator filtering, low voltage).

Application

The 723PLUS Digital Control can be programmed to suit applications requiring

two magnetic pickups (MPUs) or proximity switches (e.g. for torsional filtering) as

the hardware includes two speed inputs. It also includes four analog inputs, three

analog outputs, eight discrete inputs and three discrete outputs, all of which can

be programmed to satisfy the application. The control can be used in load

sharing systems as it contains circuitry and connections to support this.

The two LON®* channels can be used to support Woodward LonTalk®* or

LinkNet® input/output nodes control functions.

*—LON and LonTalk are trademarks of Echelon Corporation.

The 723PLUS control (Figure 1-1) consists of a single printed circuit board in a

sheet-metal chassis. Connections are via three terminal strips and three 9-pin

subminiature D connectors.

Control Options

The 723PLUS control requires the following power supply input voltages, with 40

watts as the nominal power consumption at rated voltage:

18–40 Vdc (24 or 32 Vdc nominal)

90–150 Vdc (125 Vdc nominal)

Discrete input voltages provide on/off command signals to the electronic control.

Each discrete input requires 10 mA at its 24 Vdc nominal voltage rating (for 24

volt switching logic).

Other control options are:

proximity switch input for speed signal frequencies below 100 Hz (see

NOTE)

0–1 mA for meter drivers

tandem actuator outputs

dual actuator outputs (0–200 mA)

The control may be used with either proximity switches (see NOTE) or magnetic

pickups. The minimum frequency for steady state speed control is 30 Hz. For

more information see Control Specifications (inside back cover).

723PLUS Digital Control Accessories

Hand Held Programmer (Figure 1-2), part number 9907-205. can be used

for adjusting the 723PLUS control. It plugs into serial port J1 of the control.

This part is EU Directive compliant.

SPM-A Synchronizer, for synchronizing the generator phase to that of the

power bus. The synchronizer generates a close generator breaker signal to

parallel the generator with the power bus.

Power Output Sensor, for load sharing or droop operation in mechanical

load applications.

Real Power Sensor, for load sharing or droop-parallel generator

applications.

Digital Synchronizer and Load Control (DSLC™) for generator load

management.

Rack Position Sensor, for mechanical load sharing.

Load Pulse Unit, for improved system load transient response.

LinkNet nodes for additional input/output control functions.

Scope

This chapter contains general installation instructions for the 723PLUS control.

Power requirements, environmental precautions, and location considerations are

included to help you determine the best location for the control. Additional

information includes unpacking instructions, electrical connections, and

installation checkout procedures.

Unpacking

Before handling the control, read page v, Electrostatic Discharge Awareness. Be

careful when unpacking the electronic control. Check the control for signs of

damage such as bent panels, scratches, and loose or broken parts. If any

damage is found, immediately notify the shipper.

Power Requirements

The high-voltage versions of the 723PLUS Digital Speed Control require a

voltage source of 90 to 150 Vdc. The low-voltage versions require a voltage

source of 18 to 40 Vdc

Location Considerations

Consider these requirements when selecting the mounting location:

adequate ventilation for cooling

space for servicing and repair

protection from direct exposure to water or to a condensation-prone

environment

protection from high-voltage or high-current devices, or devices which

produce electromagnetic interference in excess of levels defined in

EN50082–2

avoidance of vibration

selection of a location that will provide an operating temperature range of

40 to +70 °C (–40 to +158 °F)

Specific Marine Installation Requirements

Marine Type approval requirements change over time. In recent years, there has

been at least the addition of a stricter emission limit. A 156–165 MHz band notch

has been added and referred to here as the “Marine Notch”. To address the

Marine Notch, additional installation limitations are required for new installations

under the updated Marine Type approvals.

All wiring, except for the last 12 inches (305 mm) adjacent to the control

connection terminals must be inside a metal conduit, metal cable armoring,

enclosed metal cable way, or similar metal acting as a secondary shield. The

metal acting as the secondary shield must be grounded to the same reference

ground as the control chassis. In some cases, the chassis reference ground is

also referred to as Protective Earth (PE). All wiring must also follow the wiring

and shielding requirements given in the specific, separate software manual.

The control must be mounted on a metal mounting plate that is grounded to the

same reference ground potential as the control’s chassis.

Alternatively, if the installation is limited to areas of the ship where at least 6 dB

  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE,51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732-001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell TDC‑3000 BASIC,XLCNE2 LCN Extender,51305508‑100.Coaxial LCN
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module
  • Shinkawa JBP-47 P-22-48A-1 / P-22-48B-1 Circuit Board Module
  • Shinkawa MODEL VM-5K DUAL VIBRATION MONITOR
  • Shinkawa CMU-15A (CMU15A) Industrial Camera Controller
  • Shinkawa CMU-13A CMU13A Industrial Camera Controller
  • Shinkawa EFU-10 (EFU10) Spark Generator Unit
  • Shinkawa UTC-1000 ZUP-02C Board
  • Shinkawa MDP-89 MDP89 P-24-674A P-24-674B Circuit Board Module
  • Shinkawa CB-1011005001 Signal Cable Assembly
  • SHINKAWA VL-202A08L-1002 Sensor VL-08020L01 Probe Cable F84N1695
  • Shinkawa VK-202A2 Driver & VL-202A08L-1A72 Proximity Sensor Probe
  • SHINKAWA VM-703B VIBRATION MONITORING SYSTEM CARD 2R05-002-P001C
  • Shinkawa BH-150-03 Signal Conditioner / Preamplifier Unit
  • Shinkawa BH-150 BH150 Signal Conditioner / Preamplifier Unit
  • Shinkawa Electric VM-3D2 Thrust Monitor Module
  • Shinkawa LCU-37 Monitoring module
  • Shinkawa LCU-44B-06 Local Control Unit Module
  • ABB 3BHE039724R2643 PPD513 high-performance programmable controller module
  • Samsung SSAS21-RTD Resistance Temperature Detector Input Module
  • Samsung SSAS21-DO Digital Output Module
  • Samsung SSAS21-DI Digital Input Module
  • Samsung SSAS21-CPU Central Processing Unit Module
  • Samsung SMTB-RTD RTD/TC Terminal Board
  • Samsung SMTB-AI Analog Input/Output Terminal Board
  • Samsung SMTB-DO Digital Output Terminal Board
  • Samsung SMTB-DI Digital Input Terminal Board
  • SAMSUNG SMBK-12 IOU Rack Backplane
  • SAMSUNG SMBK-08 IOU Rack Backplane
  • SAMSUNG SMPS-08 Rack Power Module
  • SAMSUNG SMCOM-08 Communication Expansion Card
  • SAMSUNG SMPI-8 Pulse Count Input Module
  • SAMSUNG SMTC-8 Thermocouple Input Module
  • SAMSUNG SMAOC-12 Analog Output Module (12CH)
  • SAMSUNG SMAOC-8 Analog Output Module (8CH)
  • SAMSUNG SMAIC-12 Analog Current Input Module (12CH)
  • SAMSUNG SMRTD-8 RTD Pt100 Temperature Input Module (8CH)
  • SAMSUNG SMAIC-8 Analog Input Module (8CH)
  • SAMSUNG SMDO-8 Digital Output Module (8CH)
  • SAMSUNG SMDI-8 Digital Input Module (8CH)
  • SAMSUNG SMCPU-08 Central Processing Unit Controller
  • Embedded MXM GPU Modules EGX-MXM-A4500 ADLINK
  • Embedded MXM GPU Modules EGX-MXM-AD2000 ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-AD3500
  • ADLINK Embedded MXM GPU Modules EGX-MXM-AD5000
  • Embedded MXM GPU Modules EGX-MXM-AD ADLINK
  • Embedded MXM GPU Modules MXM-AXe ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-BW500
  • Embedded MXM GPU Modules EGX-MXM-BW2000 ADLINK
  • ADLINK Embedded MXM GPU Modules EGX-MXM-BW4000
  • Embedded MXM GPU Modules EGX-MXM-BW5000 ADLINK
  • SAMSUNG SSAS-PRO SPTB-AI dedicated analog input terminal board
  • SAMSUNG SSAS-PRO SPTB-DO dedicated digital output terminal board
  • SAMSUNG SSAS-PRO SPTB-DI dedicated terminal board
  • SAMSUNG SSAS-PRO SPBK-X32-12 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPBK-X32-08 Heavy-duty 8-slot system chassis backplane
  • SAMSUNG SSAS-PRO SPSU-X32 heavy-duty rack-mounted
  • SAMSUNG SSAS-PRO SPIRU-16 versatile universal mixed I/O module
  • SAMSUNG SSAS-PRO SPRI-16 RTD Temperature Input Module
  • SAMSUNG SSAS-PRO SPAO-8 Analog Output Module
  • SAMSUNG SSAS-PRO SPAI-16 Analog Input Module
  • SAMSUNG SSAS-PRO SPRDO-16 Relay digital output module
  • SAMSUNG SSAS-PRO SPDO-16 (Transistor Digital Output Module)
  • SAMSUNG SSAS-PRO SPDI-24 high-density digital input module
  • SAMSUNG SPDI-16 (Digital Input Module)
  • ADLINK 3U Enclosures & Systems AD-3100
  • Power Supplies cPS-H300S/AC ADLINK
  • Power Supplies cPS-H300S/AC ADLINK
  • CPCI Serial Peripheral cPCI-A3H10 ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3XMC
  • CPCI Serial Peripheral cPCI-A3H20 ADLINK
  • CPCI Serial Peripheral cPCI-A3MXM ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3COM
  • CPCI Serial Peripheral cPCI-A3USB ADLINK
  • ADLINK CPCI Serial Peripheral cPCI-A3ETH
  • CPCI Serial Peripheral cPCI-A3CAN ADLINK
  • 3U CompactPCI Serial Blades cPCI-A3525 Series
  • 3U CompactPCI Serial Blades cPCI-A3535 Series ADLINK
  • CompactPCI Backplanes cBP-6402 ADLINK
  • ADLINK CompactPCI Backplanes cBP-6402R
  • ADLINK CompactPCI Backplanes cBP-6105R
  • CompactPCI Backplanes cBP-6405R ADLINK
  • CompactPCI Backplanes cBP-6108F ADLINK
  • CompactPCI Backplanes cBP-6108R ADLINK
  • CompactPCI Backplanes cBP-6014R ADLINK
  • ADLINK 6U Enclosures & Systems cPCIS-6130R
  • ADLINK 6U Enclosures & Systems cPCIS-6230R/ 6240R Series
  • ADLINK 6U Enclosures & Systems cPCIS-6235R
  • ADLINK 6U Enclosures & Systems cPCIS-6400X Series
  • ADLINK 6U Enclosures & Systems cPCIS-6400U Series
  • ADLINK 6U Enclosures & Systems cPCIS-6418U
  • ADLINK ADLINK 6U Enclosures & Systems cPCIS-3300BLS