723PLUS Digital Control

9906-619. 9906-620. 9906-700

This manual describes the Woodward 723PLUS Digital Control hardware,

9906-619 (low voltage), 9906-620 (high voltage), and 9906-700 (modified

actuator filtering, low voltage).

Application

The 723PLUS Digital Control can be programmed to suit applications requiring

two magnetic pickups (MPUs) or proximity switches (e.g. for torsional filtering) as

the hardware includes two speed inputs. It also includes four analog inputs, three

analog outputs, eight discrete inputs and three discrete outputs, all of which can

be programmed to satisfy the application. The control can be used in load

sharing systems as it contains circuitry and connections to support this.

The two LON®* channels can be used to support Woodward LonTalk®* or

LinkNet® input/output nodes control functions.

*—LON and LonTalk are trademarks of Echelon Corporation.

The 723PLUS control (Figure 1-1) consists of a single printed circuit board in a

sheet-metal chassis. Connections are via three terminal strips and three 9-pin

subminiature D connectors.

Control Options

The 723PLUS control requires the following power supply input voltages, with 40

watts as the nominal power consumption at rated voltage:

18–40 Vdc (24 or 32 Vdc nominal)

90–150 Vdc (125 Vdc nominal)

Discrete input voltages provide on/off command signals to the electronic control.

Each discrete input requires 10 mA at its 24 Vdc nominal voltage rating (for 24

volt switching logic).

Other control options are:

proximity switch input for speed signal frequencies below 100 Hz (see

NOTE)

0–1 mA for meter drivers

tandem actuator outputs

dual actuator outputs (0–200 mA)

The control may be used with either proximity switches (see NOTE) or magnetic

pickups. The minimum frequency for steady state speed control is 30 Hz. For

more information see Control Specifications (inside back cover).

723PLUS Digital Control Accessories

Hand Held Programmer (Figure 1-2), part number 9907-205. can be used

for adjusting the 723PLUS control. It plugs into serial port J1 of the control.

This part is EU Directive compliant.

SPM-A Synchronizer, for synchronizing the generator phase to that of the

power bus. The synchronizer generates a close generator breaker signal to

parallel the generator with the power bus.

Power Output Sensor, for load sharing or droop operation in mechanical

load applications.

Real Power Sensor, for load sharing or droop-parallel generator

applications.

Digital Synchronizer and Load Control (DSLC™) for generator load

management.

Rack Position Sensor, for mechanical load sharing.

Load Pulse Unit, for improved system load transient response.

LinkNet nodes for additional input/output control functions.

Scope

This chapter contains general installation instructions for the 723PLUS control.

Power requirements, environmental precautions, and location considerations are

included to help you determine the best location for the control. Additional

information includes unpacking instructions, electrical connections, and

installation checkout procedures.

Unpacking

Before handling the control, read page v, Electrostatic Discharge Awareness. Be

careful when unpacking the electronic control. Check the control for signs of

damage such as bent panels, scratches, and loose or broken parts. If any

damage is found, immediately notify the shipper.

Power Requirements

The high-voltage versions of the 723PLUS Digital Speed Control require a

voltage source of 90 to 150 Vdc. The low-voltage versions require a voltage

source of 18 to 40 Vdc

Location Considerations

Consider these requirements when selecting the mounting location:

adequate ventilation for cooling

space for servicing and repair

protection from direct exposure to water or to a condensation-prone

environment

protection from high-voltage or high-current devices, or devices which

produce electromagnetic interference in excess of levels defined in

EN50082–2

avoidance of vibration

selection of a location that will provide an operating temperature range of

40 to +70 °C (–40 to +158 °F)

Specific Marine Installation Requirements

Marine Type approval requirements change over time. In recent years, there has

been at least the addition of a stricter emission limit. A 156–165 MHz band notch

has been added and referred to here as the “Marine Notch”. To address the

Marine Notch, additional installation limitations are required for new installations

under the updated Marine Type approvals.

All wiring, except for the last 12 inches (305 mm) adjacent to the control

connection terminals must be inside a metal conduit, metal cable armoring,

enclosed metal cable way, or similar metal acting as a secondary shield. The

metal acting as the secondary shield must be grounded to the same reference

ground as the control chassis. In some cases, the chassis reference ground is

also referred to as Protective Earth (PE). All wiring must also follow the wiring

and shielding requirements given in the specific, separate software manual.

The control must be mounted on a metal mounting plate that is grounded to the

same reference ground potential as the control’s chassis.

Alternatively, if the installation is limited to areas of the ship where at least 6 dB

  • Woodward easYgen-2300-1/P1 8440-2122
  • Woodward easYgen-2300-5/P1 8440-2080
  • Woodward -5/P2 8440-1858 Genset Control
  • Woodward -5/P2 8440-1857 Genset Control
  • Woodward 8440-1856 Genset Control
  • Woodward 8440-1855 Genset Control
  • Woodward 8440-2255 Genset Control
  • Woodward 8440-2256 Genset Control
  • ABB AX411/511010/STD Single and dual input analyzers
  • Woodward AX411/511010 Single and dual input analyzers
  • Woodward 8440-2253 Engine Control
  • Woodward easYgen-1400 Manual: 37799. 37889 8440-2251
  • Woodward easYgen-400 Manual: 37884. 37890 8440-2250
  • Woodward High Output DVP, 12KW TB Input/Output 8200-556
  • Woodward High Output DVP, 10KW TB Input/Output 8200-536
  • Woodward High Output DVP, 5KW TB Input/Output 8200-538
  • Woodward 8200-188 723PLUS Digital Speed Control
  • Woodward 8200-186 723PLUS Digital Speed Control
  • A-B 80190-100-01-R Regulator / Logic Control Board
  • A-B 80190-099-01 I/O Interface / Regulator PCB
  • A-B 80190-479-01 Power Logic / Gate Driver Board
  • A-B 80190-480-01-R Power Logic Board / Gate Driver
  • Woodward IP30. TB Input/Output 8200-507
  • Woodward TG-10E, -13E, and –17E Actuator 9904-110
  • Woodward TG to TG611 Conversion Kit 8516-174
  • Woodward TG-17 9904-800 Legacy Mechanical Governors
  • Woodward TG-13 9904-814 Legacy Mechanical Governors
  • Woodward CPC-DX - Dual Redundant Skid model 8918-116
  • Woodward CPC-II - 10 Bar, Class 1, Div. 1 (Zone 1 & 2) 9907-1199
  • Woodward Standard MicroNet+ KitSpeed Combo Module 8262-3183
  • Woodward MicroNet TMR Hardware 8262-1145
  • Woodward Flex500 – Front Panel Mount, LVDC, OCP (8200-1343)
  • Woodward 2300E – Ordinary Locations 8273-1017
  • Woodward Vertex Compressor Control 8200-1370
  • MicroNet Safety Module - Bulkhead Mount 8237-2492 Woodward
  • ProTech TPS - Bulkhead Mount Independent Relays 8237-2602
  • Woodward ProTech-GII - Bulkhead Mount Independent Relays 8237-2594
  • Woodward ProTech-SX - Panel Mount, HV/LV 8237-1242 8237-1243
  • Woodward SPC Servo Position Controller 8200-226 8200-227
  • Woodward Peak200 – Bulkhead Mount, LV 8200-1500
  • Woodward 505HT for Pelton Turbines 8200-1400, 8200-1401
  • Woodward 2301E-HT Hydro (Francis Turbines) P/N 8237-2046
  • Woodward 8273-1013 8273-1014 Digital Electronic Load Sharing
  • Control Panel 9907-2024 Woodward
  • Woodward 8269-1073 17-inch Industrial Touch Panel PC
  • Woodward 5009XT Triple Redundant Turbine Control (8262-1142 & 8262-1143)
  • woodward 5009XT with 2 120 V AC/DC PS 8262-1141
  • woodward RemoteView Software License 8928-5311
  • Woodward 8200-1204 8200-1205 LinkNet-HT Discrete Output Module (16 DOs)
  • Woodward LinkNet-HT RTD Module (8 RTD Inputs) 8200-1200
  • Woodward 8200-1203 LinkNet-HT Analog 4-20 mA Module (8 AI and 2 AO)
  • Woodward 8200-1331 505-DR - HVAC/DC, Ordinary Location
  • Woodward 8200-1330 505-DR - LVDC, Ordinary Location
  • Woodward 8200-1312 505-XT - LVDC, Zone-2 Hazardous Location
  • Woodward 8200-1311 505-XT - HVAC/DC, Ordinary Location
  • Woodward 8200-1310 505XT Digital Turbine Controller
  • ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
  • UniOP MD03R-02-0042 4-Line HMI Display - Technical Specs | Relianca
  • UniOP MD00R-04-0045 HMI Text Display - Specs & Technical Support | Relianca
  • UniOP MKDR-16-0045 Exor UniOP
  • UniOP CP01R-04-0045 Technical Manual & Specifications | Relianca
  • ABB PPD513 A2A-11165 High-performance controller
  • UniOP eTOP30-0050 operation panel
  • UNIOP CP01F-02-0045 HMI
  • UNIOP eTOP06-0050 A versatile and compact human-machine interface
  • UniOP eTOP10B-0050 Touch Screen Control Panel
  • UniOP CP10G-04 CP10G-04-0045 Interface Module
  • UNIOP MKDR-04-0021 Monochrome LCD (with Contrast Control)
  • UNIOP eTOP03-0046 Monochrome LCD (STN)
  • UNIOP MKDR-16-TA-0045 HMI TOUCH SCREEN
  • UNIOP Operator Interface Display MD02R-04-0042
  • UniOP Display Screen eTOP20C-0050 eTOP20C
  • UniOp eTOP05-0045 eTOP05. eTOP05P Operator Interface Touch Panel
  • UNIOP ETOP11-0050 HMI 5.6Color Operator Interface Touch Panel
  • UniOp eTOP306 Panel
  • UniOP CP04F-04-0045 Human Machine Interface
  • UniOP eTOP308 ETOP308U301 HMI Panel
  • UniOP MD00R-02-0045 Ultra-Compact Industrial Operator Terminal
  • UniOP ePALM10-0061 Handheld Robot Trainer
  • ​UniOP CP05R-04-0045 High-Value Character Operator Terminal
  • UniOP CP01R-04. CP05R-04 and CP01F-02
  • Uniop MD02R-04 - MD02R-04-0045 Industrial PLC Workstation
  • Uniop Cp02r-04-0021 Operating Interface
  • UniOP CP04F-04-1945 Rugged VFD Operator Interface
  • UniOP ECT-16-0045 High-Performance Color Touchscreen HMI
  • UniOP ERT-16-0042 High-Durability Industrial Operator Interface
  • UniOP ePAD04-0046 Compact Industrial Interface
  • UniOP BKDR-16 High-Reliability Monochrome Operator Interface
  • UniOP MKDR-04-004 Control Unit Panel
  • UniOP eTOP515 Series 500 HMI
  • Woodward 8200-1300 High-Precision 505D Steam Turbine Controller
  • ABB PFSK138 3BSE016323R3 High-Performance Digital Board Connection Unit
  • ABB PFSK163 3BSE000435R1 High-Performance Interface Module
  • UniOP ETT-VGA Human-Machine Interface (HMI) terminal
  • ABB PFSK165 3BSE027778R1 VP74201-933CW07 Signal Processing and Communication Unit
  • ABB PFSK164 3BSE021180R1 Tension sensor module and processing board
  • ABB 3BSE006505R1 PFSK 142 Control board
  • ABB PFSK160A 3BSE009514R1 Regulated High-Capacity 24V DC
  • ABB PFSK162 3BSE015088R1 High-performance signal conditioning and processing board
  • ABB PFSK152 3BSE018877R1 Signal concentrator board
  • ALSTOM PIB1201A 3BEC0067 Power Interface Board (PIB)
  • ALSTOM PIB310 3BHB0190 Adapter Module / Printed Circuit Board (PCB)
  • ALSTOM PIB102A 3BEB0180 Communication Card / PCB Module
  • ALSTOM BGTR8HE 24491276A1004 High-Frequency Power Controller / Rack Module
  • ALSTOM AM164 Analog Output / Remote I/O
  • ALSTOM UT150-1 PID temperature controller / process control board
  • ALSTOM AL132 AL132A STO0982E01 Control Motherboard / CPU Card
  • ALSTOM AS111-1 Analog Output (AO) Module
  • ALSTOM AH116-2 Servo Drive / Control Module
  • ALSTOM V4555724-0100 Electromechanical Contactor /Power Switch
  • WATLOW 999D,999A Digital/Analog Dual-Channel Base Unit
  • WATLOW 998D 998A Digital/Analog Dual-Channel Base Unit
  • WATLOW 999D-11FF-AARG Dual-channel digital unit with universal process outputs
  • WATLOW Wattlo 998D-22KK-ARRG is a high-performance dual-channel digital controller.
  • WATLOW 996A Single-loop controller
  • WATLOW 996D-11CC-CUGR Single-loop digital controller
  • WATLOW 996D Single-Channel Digital Temperature/Process Controller
  • WATLOW 997D Digital Dual-Channel Base Unit
  • WATLOW 997A Analog Dual-Channel Variant
  • WATLOW DAC / SDAC,Digital-to-Analog / Serial-to-Analog Modules
  • WATLOW MLS300-OIT Operator Interface Terminal (Keypad/Display),Discontinued
  • WATLOW CIM300 Communication Interface Module (EIA-232/485),Discontinued
  • WATLOW MLS300-CIM Control Interface Module (Comm Bridge),Discontinued
  • WATLOW MLS300-AIM,Analog Input Module (16-channel expansion),Discontinued
  • WATLOW MLS300-PM Processor Module (Central CPU),Discontinued
  • Watlow MLS332 32-Loop Processor Base Unit,Discontinued
  • Watlow MLS316 Multi-loop thermal controller
  • Watlow CLS208 C10000CP high-performance, 8-loop PID temperature controller