Woodward LinkNet-HT RTD Module (8 RTD Inputs) 8200-1200
Woodward LinkNet-HT RTD Module (8 RTD Inputs) 8200-1200
The Woodward 8200-1200 is a high-density, distributed I/O module from the LinkNet-HT™ series.
Unlike the 505 or Peak150 series which are standalone turbine controllers, the 8200-1200 is an expansion module designed to provide temperature monitoring capabilities for complex control systems like the MicroNet™ or Peak200.
It specializes in resistance temperature detector (RTD) inputs, allowing the main controller to monitor bearing temperatures, winding temperatures, or process steam heat with high precision.
Technical Parameter Table
| Feature | Specification |
| Model Number | 8200-1200 |
| Module Type | LinkNet-HT RTD Input (8 Channels) |
| Input Type | 100 $Omega$ or 200 $Omega$ Platinum RTDs (3-wire) |
| Communication | CANOpen (Simplex LinkNet-HT protocol) |
| Power Input | 18–36 Vdc (External loop power) |
| Resolution | 16-bit A/D Conversion |
| Operating Temp | –40 °C to +70 °C |
| Environmental | Class G3 Conformal Coating (H2S/Sulfur Resistant) |
| Certifications | CSA Class I, Div 2; ATEX/IECEx Zone 2 |
| Mounting | DIN Rail Mount (Standard 35mm) |
Product Advantages and Features
Distributed Architecture: Allows temperature sensors to be wired to a local module near the turbine, reducing the cost of long, expensive cable runs back to the main control room.
High Precision: 16-bit resolution ensures accurate temperature tracking, which is critical for identifying early signs of bearing wear or cooling system failure.
Ruggedized for Industry: Featuring Class G3 conformal coating, this module is built to withstand the "rotten egg" smell of H2S gas and other corrosive elements common in paper mills and refineries.
Hot-Swappable: Designed to be replaced while the system is energized (depending on the base system configuration), minimizing downtime during maintenance.
Smart Diagnostics: Automatically detects open circuits or shorted sensors, providing immediate feedback to the master controller to prevent false trips.
Unique Product Description
The Woodward 8200-1200 is the "sensory nervous system" for modern turbine setups.
While the main governor handles the muscle (actuators), the 8200-1200 acts as a specialized data-hub for heat.
Its unique value lies in its CANOpen-based LinkNet-HT architecture, which allows it to integrate seamlessly into a "daisy-chain" of other I/O modules.
This modularity means you only pay for the I/O you need, making it a highly scalable solution for everything from small pumps to massive utility-grade turbines.
Application Cases
Bearing Temperature Monitoring: Continuous tracking of turbine and generator bearing temperatures to prevent catastrophic mechanical failure.
Generator Stator Protection: Monitoring the temperature of the internal windings in synchronous generators.
Heat Exchanger Efficiency: Measuring inlet and outlet steam/water temperatures to calculate thermal efficiency.
Lube Oil Systems: Ensuring that the turbine's oil remains within the specified viscosity range by monitoring the reservoir and supply lines.
Installation and Maintenance
Wiring: Use 3-wire RTDs to ensure lead-wire resistance compensation. Shielded cabling is mandatory for environments with high electromagnetic interference (EMI).
Network Termination: Since it uses CAN communication, ensure the LinkNet-HT network is properly terminated with a 120 $Omega$ resistor at both ends of the trunk line.
Power: Ensure the 24V DC power supply is stable; a power-cycle on the module will temporarily drop all 8 temperature readings to the master controller.
Address Setting: Each 8200-1200 on a single CAN bus must have a unique node address, typically set via rotary switches or software configuration.
Other Models in the Same Series
| Model | Function | Channels | Communication |
| 8200-1201 | Thermocouple (TC) Input | 8 Channels | LinkNet-HT |
| 8200-1202 | Analog I/O (4-20mA) | 8 In / 2 Out | LinkNet-HT |
| 8200-1203 | Analog I/O (Loop Power) | 8 In / 2 Out | LinkNet-HT |
| 8200-1204 | Discrete Input (DI) | 16 Channels | LinkNet-HT |
| 8200-1205 | Discrete Output (DO) | 16 Channels | LinkNet-HT |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|