Aerotechs Network Digital Drives (Ndrive HP) complement the Automation 3200
System (see Figure 1-1). Connected via the IEEE-1394 (FireWire®) communication bus,
these drives provide deterministic behavior, auto-identification, and easy software setup
from the Nmotion SMC software controller. Featuring a high-speed Harvard architecture
DSP, the drives have fully digital current and servo loops providing selectable 1-20 kHz
servo loop closure, 40 MHz line driver encoder data rate, and an optional Ethernet port
for access to third party networked I/O solutions. The Ndrive HP also features an
optional on-board brake relay, programmable resolution multiplication up to x 65,536,
with a 200 kHz maximum amplified sine wave input frequency, and up to three-axis
Position Synchronized Outputs (laser firing). In addition, the use of the commercially
standard FireWire communication link makes integration to the Automation 3200
network plug-n-play easy.
1.1. Feature Summary
• Software configurable for brush, brushless and stepper motor operation
• Standard 100 VDC 320 VDC Bus, optional 20 VDC 80 VDC Bus, requires
the -AUXPWR option
• Fully isolated power stage
• 5 VDC, 500 mA fused user output power for encoder and Hall effect signals,
etc.
• Two mounting orientations optimized for heat transfer or minimal panel space
utilization
• Full protection against the following failure modes:
1. Control supply under voltage
2. Continuous current overload
3. Power stage bias supply under-voltage
4. Power stage output short circuit (phase to phase and phase to ground)
5. DC bus over voltage
6. IGBT device over temperature sense
• Line driver square wave or analog sine wave quadrature encoder primary
position and velocity feedback
• Line driver square wave auxiliary quadrature encoder input or output for PSO
(laser firing), etc.
• 4 opto-isolated user outputs standard
• 6 opto-isolated user inputs standard, 2 of which are high speed
• 2 differential analog inputs (one standard and one available with the IOPSO
option)
• 2 analog outputs (one standard and one available with the IOPSO option)
1.2.
Connection Overview
The Ndrive HP consists of two power connections (motor power and input power), three
FireWire ports, an optional Ethernet connection, an RS-232/RS-422 connector, LED
indicator lamps and two D-Style connectors for Auxiliary I/O (15 and 26 pin) and Motor
Feedback (25 pin). An IOPSO or -IOPSOH option is also available, which has
connectors for PSO, absolute encoder, SSI Net, analog I/O, digital I/O, and user power.
Refer to Figure 1-2 for connector locations.
1.3.
Functional Diagram
The standard package includes the bus power supply that operates from 85-250 VAC
(120 350 VDC). The power supply is included with the standard package for off-line
operation without the need for an isolation transformer. A soft start circuit is included to
prevent high inrush currents.