DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
YOKOGAWA  Models 4370  µR1800 Recorder
❤ Add to collection

YOKOGAWA Models 4370 µR1800 Recorder

YOKOGAWA  ANR10D  communicates the analog I/O signals and contact I/O

6532.00
¥5871.00
¥5871.00
¥5871.00
Weight:3.000KG
Description

YOKOGAWA  ANR10D  communicates the analog I/O signals and contact I/O


Features

IM 4H3B1-01E

The µR1800 recorder is a precision measuring instrument that is equipped with many

outstanding features:

Compact sized, high reliability: Its compact size (depth 220mm) allows you to

install the µR1800 where only a limited space is available. In case of the pen model, a

contact-free potentiometer and a brushless-DC servomotor contribute to its high

reliability.  In case of the dot printing model, high reliability is obtained by the use of

high break down voltage solid-state relays.

Universal inputs: Inputs like DC-voltage, Thermocouple (TC), Resistance

Temperature Detector (RTD), and Digital Input (contact) can all be conveniently used.

There is no need to change any dipswitches; the type of input can be set using the key

board.

Easy interactive setting: The setting procedure has been made very easy, by using

only panel keys. The µR1800 asks you to select the desired settings, without the need

for remembering difficult setting-codes.

Large informative operator display: The large sized, VFD, display shows the

measured data (including the engineering units) or clock, and bargraph at the same time.

There are two types of bargraph available: percentage-display, and center-zero display.

Because of its 1%-resolution, the bargraph displays very accurately.

Continuous pen recording for up to four channels (pen model only):

Depending on your µR1800 model type, the µR1800 can measure up to four channels

simultaneously. This allows you to decrease the number of recorders you require.

Universal power supply (except for /P1 model): The µR1800 accepts 90 to

250VAC (except 132 to 180VAC), and 50/60Hz without any problems, or need to turn

switches. Therefore the µR1800 is compatible with a wide variety of power supplies.

High performance: The sampling speed of the µR1800 pen model is high at 125 ms,

whereas the recording cycle of the µR1800 dot printing model is 6 ch./10 seconds, or

12ch./15sec., 18ch./20sec. or 24ch./30sec. depending on the model.

The µR1800 is equipped with many functions. Special functions can be ordered as an

option. Furthermore, its power consumption is low (4pen model; 30VA under normal

operation conditions).

Easy maintenance: Because of the use of many contact-free parts, the need for

maintenance has been decreased. The µR1800 is designed in modules, which decreases

the time needed for maintenance extensively.

Closed case: The closed case of the µR1800 allows it to be used in many

environments. The front door is in accordance with DIN 40050-IP54.

Computer interface and memory card: If equipped with this option, the µR1800

can store and retrieve measured data as well as setting data, using an IC memory card or

directly from your PC. The available interface is RS-422-A.

Based on international safety standards: The µR1800 (except portable type) is

based on international safety standards, such as the IEC 348

Summary of Functions

This paragraph describes a summary of the main functions, together with a recording

example.

RECORDING

Trend: records in a way that the dots do not overlap (dot model only)

Zone: records on different bands (zones) for individual channels

Partial: expands part of the recording range for detailed examination

POC: Pen Offset Compensation: removes the time-axis offset between pens (pen model only)

PRINTOUT

Channel printout: contains channel No. besides analog recording (dot model only)

List printout: contains date, time, chart speed (1 & 2),  channel No. or tag, range, span values, scale

values, partial values and contents of messages (for example, see 5.3.4)

Manual printout: contains date and time, channel No., type of alarm, latest measured values, units (for all

channels)

Alarm printout: contains channel or tag No., type of alarm, level, mark (    for occurence,     for recover;

in case of the dot model, red and blue respectively) and alarm ON/OFF-time

Periodic printout: contains date & time, tag or channel No., POC ON mark ( ; for pen model only), unit,

scale markings (may not be printed while alarm occurs), chart speed, measured values

and recording color (for pen model) and time tick (for dot model)

Message printout: contains time and message

Recording start printout: contains time when recording starts

Chart speed change: contains time and new chart speed

SET UP List printout: contains initial settings concerning analog recording, digital printing, alarms, burnout,

RJC and options (for example, see 5.3.5)

NOTE The alarm, channel (for dot model), periodic, message, recording start and chart speed

change printout depend on the chart speed. The size of the characters varies depending

on the chart speed

ALARM

Type of alarms: H:high limit

L: low limit

h: high difference limit

l: low difference limit

Time tick (–)*1

R: rate-of-change limit on increasing signal

r: rate-of-change limit on decreasing signal

Hysteresis: hysteresis value as a % of span which can be 0% or approx. 0.5%

Alarm output relay: when alarm occurs, the relay will be activated (optional)

Reflash: monitors repeating alarm occurrences among a group of alarms sharing the

same output relay (optional)

FAIL/Chart-end output: output relay is activated when chart reaches its end and/or when failure of

equipment occurs (optional)

INPUT

Type of inputs: TC: Thermocouple

RTD: Resistance Temperature Detector

DC-voltage

DC-current: using optional external shunt resistor

DI: Digital Input (contact)

Burnout: when TC-wire is broken, pens will move to left or right side

Filter: (signal damping) selects the time constant of signal damping (for pen model)

Moving average: selects the number of samples for moving average (for dot model)

ALSTOMDSI1817   TRVC062335000 CP00003934
ALSTOMPOS1846   TRVC062333000 CP00000310
ALSTOMVPS   12004-102-03 V1.0.0
ALSTOMVOOB8-B   12004-106-04 VER:V1.0.0
ALSTOMV4561983-0100
ALSTOMEP3-E-4-A
ALSTOMI/OBE2   12004-104-00 V1.0.0
alstomP40   AGILE MICOM P141
ALSTOM029.144.440
ALSTOM029.144.456
ALSTOM029.147.908
ALSTOM029.148.906
ALSTOM029.148.924
ALSTOM029.202.781
ALSTOMEP3-F-4-EN
ALSTOMPIB100G
ALSTOMPIB101C
ALSTOMPIB102A
ALSTOMPIB310
ALSTOMPIB903


  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912