DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

GEInstallation and Maintenance Manual Bently Nevada™ Asset Condition Monitoring

From:GE | Author:LIAO | Time :2025-08-14 | 678 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Additional Information 

Notice:

This manual does not contain all the information required to operate and maintain 

the product. Refer to the following manuals for other required information. 

3500 Monitoring System Rack Configuration and Utilities Guide 

(129777-01) 

• guidelines for using the 3500 Rack Configuration software for setting the operating 

parameters of the module 

• guidelines for using the 3500 test utilities to verify that the input and output 

terminals on the module are operating properly 

3500 Monitoring System Computer Hardware and Software Manual 

(128158-01) 

• instructions for connecting the rack to 3500 host computer 

• procedures for verifying communication 

• procedures for installing software 

• guidelines for using Data Acquisition / DDE Server and Operator Display Software

• procedures and diagrams for setting up network and remote communications 

3500 Field Wiring Diagram Package (130432-01) 

• diagrams that show how to hook up a particular transducer 

• lists of recommended wiring 

Operation and Maintenance Manuals for all the modules installed in the 

rack 

Product Disposal Statement

Customers and third parties, who are not member states of the European Union, who are 

in control of the product at the end of its life or at the end of its use, are solely 

responsible for the proper disposal of the product. No person, firm, corporation, 

association or agency that is in control of product shall dispose of it in a manner that is 

in violation of any applicable federal, state, local or international law. Bently Nevada LLC 

is not responsible for the disposal of the product at the end of its life or at the end of its 

use. 

1. Receiving and Handling Instructions 

This will be a short overview of the entire section. 

1.1 Receiving Inspection 

Visually inspect the system for obvious shipping damage. If you detect shipping 

damage, file a claim with the carrier and submit a copy to Bently Nevada, LLC. 

1.2 Handling and Storage Considerations 

Proper handling and storing of printed circuit boards is extremely critical. Circuit 

boards contain devices that are susceptible to damage when exposed to 

electrostatic charges. Damage caused by obvious mishandling of the board will 

void the warranty. To avoid damage, observe the following precautions in the 

order given. 

Application Advisory 

Machinery protection will be lost when 

you remove all power from the rack. 

• Do not discharge static electricity onto the circuit board. Avoid tools or 

procedures that would subject the circuit board to static damage. 

Some possible causes of static damage include ungrounded soldering 

irons, nonconductive plastics, and similar materials. 

• Use a suitable grounding strap (such as 3M Velostat® No. 2060) to 

ground yourself before handling or performing maintenance on a 

printed circuit board. 

• Transport and store circuit boards in electrically conductive bags or 

foil. 

• Use extra caution during dry weather. Relative humidity less than 30% 

tends to multiply the accumulation of static charges on any surface. 

When performed properly, you may remove modules from or install modules into 

the rack while power is applied to the rack. Refer to << Section reference to 

“Module Installation in section 4 >> for the proper procedure

2. General Information 

Monitoring and computerized vibration information systems provide the 

information you need to assess the mechanical condition of rotating and 

reciprocating machinery. These systems continuously measure and monitor 

various supervisory parameters and provide crucial information for early 

identification of machinery problems such as imbalance, misalignment, shaft 

crack, and bearing failures. As such, these systems are an efficient and effective

means of satisfying plant management, engineering, and maintenance concerns 

for: 

• Increasing plant safety by minimizing the occurrence of hazardous 

conditions or catastrophic failures. 

• Improving product quality by minimizing process variances caused by 

improperly operating equipment. 

• Maximizing plant availability by servicing only those machines that 

require it and providing more efficient turnarounds. 

• Reducing plant operating costs by minimizing unplanned shutdowns 

and by making more efficient use of maintenance resources. 

For protection of critical machinery, we highly recommend that you permanently 

install continuous monitoring systems. The term "protection" means that the 

system can shut down machinery on alarm, without human interaction. These 

systems include applicable transducers, each with its own dedicated monitoring 

circuitry and alarm setpoints. The 3500 Monitoring System is the newest addition 

to the family of continuous monitoring systems offered by Bently Nevada, LLC. 

2.1 3500 Monitoring System 

  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-113 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-113 Protective Measurement Card
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK PICMG Single Board Computers NuPRO-900A
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cableles
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control