MAXIMUM DISTANCES
NOTE
Fiber cable with LC/LC connections greater than
50 m is user-supplied.
OM1(5) multimode 62.5/125 μm (max. 70 m /
230 ft)
OM2(5) multi-mode 50/125 μm cable (max.
150 m / 492 ft)
OM3(5) multi-mode 50/125 μm cable (max.
380 m / 1247 ft)
OM4(5) multi-mode 50/125 μm cable (max.
400 m / 1312 ft)
OS1, OS2(6) Single-mode 9/125 μm cable (max.
1000 m / 3280 ft)*
EMC CERTIFICATIONS
Class A: ACMA, CE, FCC, VCCI
Power Consumption and Supply Voltage
TEMPERATURE, OPERATIONAL
0° to 55 ºC (32° to 131 ºF)
TEMPERATURE, NON-OPERATIONAL,
STORAGE AND TRANSPORTATION
-40° to 70 ºC (-40° to 158 ºF)
HUMIDITY, OPERATIONAL (INDOOR)
20% to 80% (non-condensing)
HUMIDITY, NON-OPERATIONAL STORAGE
AND TRANSPORTATION
5% to 95% (non-condensing)
ATMOSPHERIC PRESSURE, OPERATIONAL
650hPa (3,580 m / 11,745 ft)
to 1013hPa (0 m / 0 ft)
ATMOSPHERIC PRESSURE, NONOPERATIONAL AND TRANSPORTATION
192hPa (12,000 m / 39,370 ft)
to 1020hPa (-50 m / -164 ft)
Power Consumption and Supply Voltage
(Continued)
ESTIMATED MTBF (MEAN TIME BEFORE
FAILURE)
Interface Card
70.81 years @ 40 ºC
Extio F2208 Unit
26.87 years @ 40 ºC (excluding power
supply)
Extio F2408 Unit
23.20 years @ 40 ºC (excluding power
supply)
Extio F2408E Expander Unit
22.68 years @ 40 ºC (excluding power
supply)
INTERFACE CARD
Maximum Power Consumption
6.5 W
EXTIO UNIT
Power Requirements
12 V dc, maximum 5 A
(5 A fuse for overcurrent protection)
Power Connector
Mini-DIN 4 female (4-pin)
MAXIMUM POWER CONSUMPTION
Calculated for the following configuration: a USB
keyboard and mouse, two other USB devices,
and four DisplayPort monitors.
External Power Supply
Input ac Voltage Range
90 to 264 V ac
Input Frequency
47/63 Hz
Input Connector
IEC 60320-C14
Output Voltage
12 V dc
Output Connector
Mini-DIN 4 male (4-pin) with lock
Maximum Power Output
60 W