DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ABB ACS850 general-purpose frequency converter

From:ABB ACS850 | Author:LIAO | Time :2025-07-24 | 493 Browse: | 🔊 Click to read aloud ❚❚ | Share:

What this chapter contains This chapter contains the safety instructions which you must follow when installing, operating and servicing the drive. If ignored, physical injury or death may follow, or damage may occur to the drive, motor or driven equipment. Read the safety instructions before you work on the unit. Use of warnings Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment and advise on how to avoid the danger. The following warning symbols are used in this manualElectricity warning warns of hazards from electricity which can cause physical injury and/or damage to the equipment. General warning warns about conditions, other than those caused by electricity which can result in physical injury and/or damage to the equipment. Electrostatic sensitive devices warning warns of electrostatic discharge which can damage the equipment. Hot surface warning warns of component surfaces that may become hot enough to cause burns if touched.


Safety in installation and maintenance Electr

ical safety These warnings are intended for all who work on the drive, motor cable or motor. WARNING! Ignoring the following instructions can cause physical injury or death, or damage to the equipment: • Only qualified electricians are allowed to install and maintain the drive. • Never work on the drive, motor cable or motor when main power is applied. After disconnecting the input power, always wait for 5 min to let the intermediate circuit capacitors discharge before you start working on the drive, motor or motor cable. Always ensure by measuring with a multimeter (impedance at least 1 Mohm) that: 1. voltage between drive input phases U1, V1 and W1 and the frame is close to 0 V. 2. voltage between terminals UDC+ and UDC- and the frame is close to 0 V. • Do not work on the control cables when power is applied to the drive or to the external control circuits. Externally supplied control circuits may cause dangerous voltages inside the drive even when the main power on the drive is switched off. • Do not make any insulation or voltage withstand tests on the drive or drive modules. Note: • The motor cable terminals on the drive are at a dangerously high voltage when the input power is on, regardless of whether the motor is running or not. • The brake control terminals (UDC+, UDC-, R+ and R- terminals) carry a dangerous DC voltage (over 500 V). • Depending on the external wiring, dangerous voltages (115 V, 220 V or 230 V) may be present on the terminals of relay outputs (X2) or Safe torque off (X6). • The Safe torque off function does not remove the voltage from the main and auxiliary circuits.


Grounding These instructions are intended for all who are responsible for the grounding of the drive. WARNING! Ignoring the following instructions can cause physical injury, death, increased electromagnetic interference and equipment malfunction: • Ground the drive, motor and adjoining equipment to ensure personnel safety in all circumstances, and to reduce electromagnetic emission and interference. • Make sure that grounding conductors are adequately sized as required by safety regulations. • In a multiple-drive installation, connect each drive separately to protective earth (PE). • Where EMC emissions must be minimized, make a 360° high frequency grounding of cable entries at the cabinet lead-through in order to suppress electromagnetic disturbances. In addition, connect the cable shields to protective earth (PE) in order to meet safety regulations. Note: • Power cable shields are suitable for equipment grounding conductors only when adequately sized to meet safety regulations. • As the normal leakage current of the drive is higher than 3.5 mA AC or 10 mA DC, a fixed protective earth connection is required by EN 61800-5-1, 4.3.5.5.2.


Permanent magnet motor drives These are additional warnings concerning permanent magnet motor drives. WARNING! Ignoring the instructions can cause physical injury or death, or damage to the equipment. • Do not work on the drive when the permanent magnet motor is rotating. Also, when the supply power is switched off and the drive is stopped, a rotating permanent magnet motor feeds power to the intermediate circuit of the drive and the supply connections become live. Before installation and maintenance work on the drive: • Stop the motor. • Ensure that there is no voltage on the drive power terminals according to step 1 or 2, or if possible, according to the both steps. 1. Disconnect the motor from the drive with a safety switch or by other means. Measure that there is no voltage present on the drive input, output or DC terminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-). 2. Ensure that the motor cannot rotate during work. Make sure that no other system, like hydraulic crawling drives, is able to rotate the motor directly or through any mechanical connection like felt, nip, rope, etc. Measure that there is no voltage present on the drive input, output or DC terminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-). Ground the drive output terminals temporarily by connecting them together as well as to the PE.

  • ABB PFVL142R-40MN Ultra-High Capacity Roll Force Load Cell
  • ABB PFVL142R-30MN Industrial Roll Force Load Cell
  • ABBP PFVL142R-25MN Ring-shaped (circular) load cell
  • ABBP FVL142R-20MN Heavy-duty circular load cell
  • ABB PFVL142R-16MN Heavy-duty circular load cell
  • ABB PFVL142R-10MN High-precision and high-strength ring-shaped weighing sensor
  • ABB 3BSE023732R1 PFVO142 Matching unit 25A, 1638 Hz
  • ABB Annular load cells QGPR 104/102
  • ABB Annular load cells PFVL141R
  • ABB Rectangular load cells PFVL141V
  • ABB Circular load cells PFVL141C
  • Metso Automation D201776 ACN PO DC PLC Control Server Computer
  • Nidec MP700A5 / MP700A5R (700A) high-performance DC thyristor drives
  • Nidec Control Techniques MP470A5 / MP470A5R (470A)
  • Nidec Control Techniques MP350A5 / MP350A5R (350A)
  • Nidec Control Techniques MP210A5 / MP210A5R (210A)
  • Nidec Control Techniques MP155A5 / MP155A5R (155A)
  • Nidec Control Techniques MP105A5 / MP105A5R (105A)
  • Nidec Control Techniques MP75A5 / MP75A5R (75A)
  • Nidec Control Techniques MP25A5 / MP25A5R (25A)
  • Nidec Control Techniques MP1850A4 / MP1850A4R (1850A)
  • Nidec Control Techniques MP1200A4 / MP1200A4R (1200A)
  • Nidec Control Techniques MP900A4 / MP900A4R (900A) Overview
  • ABB PFSA240 Roll DC Supply Unit 3BSE073476R1
  • GE AT868-2-1-1 Flow Meter
  • Nidec Mentor MP825A4 / MP825A4R (825A) High-Power DC Drive
  • Nidec Mentor MP700A4 / MP700A4R (700A) DC Drive
  • Nidec MP550A4 / MP550A4R(550A) high-power DC thyristor drive
  • Nidec Mentor MP420A4 / MP420A4R (420A) High-Power DC Drive
  • Nidec Mentor MP350A4 / MP350A4R (350A) High-Power DC Drive
  • Nidec Mentor MP210A4 / MP210A4R(210A) Industrial DC Drive
  • Nidec Mentor MP155A4 / MP155A4R (155A) Industrial DC Drive
  • Nidec Mentor MP105A4 / MP105A4R (105A) Industrial DC Drive
  • Nidec Mentor MP75A4 / MP75A4R (75A) High-Performance DC Drive
  • Nidec MP45A4 / MP45A4R – 45Amp 15kW 4 QUADRANT INDUSTRIAL DCDRIVE
  • Nidec MP25A4 / MP25A4R (25A) Industrial Driver
  • Applied Materials (AMAT) 0100-16009 SMIF-Asyst Wide Body Interlock PCB
  • Applied Materials (AMAT) 0100-09134: DIO Fuse Board Assembly
  • Applied Materials (AMAT) 0100-09107 TEOS Gas Interface Board
  • Applied Materials (AMAT) 0100-09094 TEOS Box Heater Control Board
  • Applied Materials (AMAT) 0100-09071 SBC I/O Breakout Board
  • Applied Materials (AMAT) 0100-09010 System Electronics Backplane
  • Applied Materials (AMAT) 0100-09006 Intelligent Interface SBC Module
  • Applied Materials (AMAT) 0100-03920 Analog I/O Interface Board
  • Applied Materials (AMAT) 0100-00511 / 0130-00511: Mainframe I/O Display
  • Applied Materials (AMAT) 0100-00156 Precision Isolation Amplifier Board
  • Applied Materials (AMAT) 0100-00052 High-Performance Communication Interface
  • Autronica Controller rack unit BC-250
  • Autronica Mimic cabinet BUR-200. for maritime installations
  • Autronica Mimic driver BUR-200
  • Autronica Information panel BV-210
  • Autronica Fire brigade panel BU-210
  • Autronica Repeater panel BS-211
  • Autronica Maritime fire alarm control panel BS-200M
  • Autronica Fire alarm control panel BS-200
  • AMAT 0100-00046 AC Current Sense PWB
  • AMAT A0414720 Precision Advanced System Controller
  • AMAT 0010-00017 Precision Semiconductor Process Interface
  • AMAT 01-82889-00 High-Performance Semiconductor Component
  • ABB Sample Gas Cooler SCC-C 23070-0-10232110
  • IBA ibaRackline-PCHD Efficient process analysis with ibaHD-Server
  • IBA ibaRackline-PC CAM Frame-accurate video information with ibaCapture
  • IBA ibaRackline-PC Highly available and reliable
  • IBA Optical Signal Multiplier ibaBM-FOX-i-3o-D
  • IBA Optical Data Distribution System ibaBM-DIS-i-8o
  • IBA Optical Data Concentrator ibaBM-COL-8i-o
  • IBA ibaNet750-BM-D Acquisition via FO
  • IBA ibaW-750 Acquisition via Ethernet
  • IBA ibaPADU-8AI-I Compact Measurement Modules
  • IBA ibaPADU-D-8AI-I Compact Measurement Modules
  • IBA ibaPADU-8AI-U Compact Measurement Modules
  • IBA ibaPADU-D-8AI-U Compact Measurement Modules
  • IBA ibaPADU-4-AI-U Compact Measurement Modules
  • IBA ibaPADU-C-8AI Self-Supplied Data Logger
  • IBA ibaBM-ENetIP Bus monitor for EtherNet/IP
  • IBA ibaBM-eCAT Bus monitor for EtherCAT
  • IBA ibaBM-DP Bus monitor for PROFIBUS
  • IBA ibaBM-PN: Bus monitor for PROFINET IO
  • IBA ibaMS3xAI-1A Precision AC Current Measurement Module
  • IBA ibaDAQ Intelligent Central Unit
  • IBA ibaPQU-S Power Quality Monitoring System
  • IBA ibaCMU-S Condition Monitoring Unit (CMU)
  • IBA ibaPADU-S-IT-2x16 Modular data acquisition and control system
  • IBA ibaPADU-S-CM Modular data acquisition system
  • IBA ibaM-4AI-IEPE Input module
  • IBA ibaM-4AI-UI Input module
  • IBA ibaM-4AI-150V-AC Input module
  • IBA ibaM-4AI-600V-AC Input module
  • IBA ibaLink-SM-256V: High-Density PLC Data Interface
  • IBA ibaLink-SM-64V High-Performance S5/S7 Interface
  • IBA ibaLink-SM-128V-i-2o Synchronous Fiber Optic (ibaNet)
  • IBA ibaLink-SM-128V communication module
  • IBA ibaM-4AI-5A-150A-AC Input module
  • IBA ibaM-FO-2IO Interface module
  • IBA ibaM-COM Communication module
  • IBA ibaM-DAQ Intelligent Processor Module
  • B&R ECE161-0 MULTI digital input module
  • B&R ECCP70-01 MULTI CPU type B 42 KByte SRAM
  • B&R ECCP60-01 MULTI CPU type B 42 KByte SRAM
  • B&R DI426 digital input module
  • B&R 2DS100.60-1 electronic drum sequencer Absolut encoder
  • B&R 2CP100.60-1 CPU MODULE
  • B&R 2BM100.9 High-performance I/O module
  • AMAT 0190-14928 SCR Power Controller (PVD Reverse Zone)
  • AMAT 0500-01065 300mm Loadlock Interface Interlock Board
  • AMAT 2000-21123 Advanced Vacuum Seal Assembly
  • AMAT 0660-00090 High-Performance Industrial Power Filter
  • AMAT 0240-34077 Centura Endpoint Controller Kit
  • AMAT 0195-10215 High-Precision Pedestal Assembly
  • AMAT 0190-76050 VGA Video Controller VME Module
  • AMAT 0190-75084 High-Performance Communication & Logic Controller
  • AMAT 0190-60287 Precision VME/cPCI Interface Control Module
  • AMAT 0190-53752 DI Water I/O Controller PCB
  • AMAT 0190-37993 DeviceNet Scanner Pro (3U CompactPCI)
  • AMAT 0190-37833 MKS CDN500R-5 EPI 300mm Interface Module
  • AMAT 0190-37771 MKS CDN500R Interlock Control Module
  • AMAT 0190-37616 High-Precision Analog Input/Output Interface
  • AMAT 0190-36787B ISAC CP I/O Block 2 (Top) - Revision B
  • AMAT 0190-36787 ISAC CP I/O Block 2 (Top)
  • AMAT 0190-36511 DIP294 DeviceNet I/O Control Block
  • AMAT 0190-35764 & 0190-35765: Precision Control Interface Duo
  • AMAT 0190-35763 High-Performance Integrated Power Module
  • Applied Materials (AMAT) 0190-34512 4-Channel DeviceNet Scanner Interface
  • Applied Materials (AMAT) 0190-34282 High-Stability Process Control Module
  • Applied Materials (AMAT) 0190-27707 High-Precision DeviceNet I/O Controller
  • Applied Materials (AMAT) 0190-27072 High-Performance Semiconductor Interface
  • AMAT 0190-24007 CPCI-3720CF Single Board Computer
  • AMAT 0190-23905 Spellman ESC High Voltage Power Supply