DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

WATLOWCLS200, MLS300, and CAS200 Communications Specification

From:WATLOW | Author:LIAO | Time :2025-08-25 | 282 Browse: | Share:

This reference guide is designed to help applications software

programmers with the following tasks:

• Interface to Watlow Anafaze MLS300, CLS200, MLS and CLS controllers, and the CAS200 and CAS scanners via serial communications.

• Modify the communications Anafaze protocol driver in the Watlow 

Anafaze Communications Driver Kit. (If you have the communications driver kit, you don’t need to read this manual unless you want 

to modify the communications driver.)

In This Manual

The following sections are included in this guide: 

Chapter 1: Anafaze/AB Protocol. Gives an overview and explanation

of the Anafaze/Allen Bradley communications protocol.

Chapter 2: Modbus-RTU Protocol. Gives an overview and

explanation of the Modbus-RTU communications protocol

Chapters 1 and 2: Data Table Summary. Provides standard controller

data table maps for the parameters (one for each protocol).

Chapter 3: Parameters Description. Describes each parameter.

Appendix A: Communications driver.

Glossary: Explanation of commonly used terms and acronyms.

NOTE

This reference guide is not a tutorial. It does not explain

how to use the controller; it is not a programming reference; it also does not explain PID control, alarms, linear

scaling, or other topics that are explained in detail in the

controller manuals. If you need additional information

about a topic covered in this reference guide, consult the

documentation included with your controller.

Chapter 1: ANAFAZE/AB Protocol

This section explains the ANAFAZE/Allen Bradley protocol used in

Watlow Anafaze MLS, CLS, and CAS devices. These controllers

operate on serial communications links (EIA/TIA-232 or EIA-TIA-485)

at either 2400 or 9600 baud. They use 8 data bits, one or 2 stop bits, and

no parity.

Protocol Syntax

The controllers use a half-duplex (master-slave) protocol to interface to

high-level software. The host software is considered the “master” and

the controller is considered the “slave.” In other words, the software can

request information from the controller or download information to the

controller. The controller can only respond to communications

transactions initiated by the host software. The controller cannot initiate

communications.

The controller and host software communicate by sending and receiving

information in a “packet” format. A packet consists of a sequence of

bytes in a specific format; it can be as large as 256 bytes of data. (For

more information about packets, see the Packet Format section later in

this chapter.)

The numbers in the packet are sent in binary format. However, our

examples show bytes in hexadecimal format.

Control Codes

Watlow Anafaze abbreviates control codes this way

Chapter 1: ANAFAZE/AB Protocol

Transaction Sequence

Here are the four steps in a transaction between the host software and

the controller. The following example shows the transaction as an

exchange of packets. The example also assumes that there are no

communication errors in the exchange.

(1) The host software sends a packet that contains a read command or 

write command.

(2) The controller sends a DLE ACK to the host software.

(3) The host software receives a reply packet from the controller. 

(4) The host software sends a DLE ACK.

The following flowchart shows a transaction with no error handling.

NOTE

Due to the difference between the processing speeds of the

controller and PCs, it may be necessary to delay the computer's acknowledgement (ACK) in order for the controller

to receive it. A delay of 200 ms should suffice

Packet Format

Messages are transmitted in the form of packets. Command and reply

packets specify the source and destination addresses, whether to read or

write, the block of data to read or write, etc.

A packet contains a sequence of binary bytes formatted this way:

Sending Control Codes

To send a control code, send a DLE before the control code to

distinguish it from data.

Sending a DLE as Data

When you send a byte with an x10, (a DLE), the controller and software

interpret it as a command. Therefore, to send a DLE as data, send

another DLE immediately before it (DLE DLE). 

Codes in a Packet

This section describes the sequence of bytes in a packet, in the order the

host software or controller sends them.

DLE STX

• The DLE STX byte signals the beginning of a transmission. Every 

packet of information starts with the control codes DLE STX. 

DST

• The DST byte is the address of the destination device (usually a controller; the first Watlow Anafaze controller is at x08).

NOTE

When host software communicates with an MLS, a CLS, or

a CAS in ANAFAZE or AB protocol, it does not send the

controller’s actual address. Since the protocol reserves

device addresses 0 to 7, the host software sends the value

(controller address + 7), instead of the actual device

address.

SRC

• The SRC byte is the device address of the packet’s source. The host 

software is usually designated address x00.

DLE STX DLE ETX BCC/CRC

DST SRC CMD STS TNSL TNSH ADDL ADDH DAT

CMD

• The CMD byte indicates the command that the host software sends 

to the controller. The software sends a read (x01) or write (x08). 

When the controller replies, it returns the read or write command 

  • EMERSON MVME61006E-0163R VMEbus Single-Board Computer
  • EMERSON Ovation 5X00453G01 Remote I/O Node Controller Module
  • EMERSON 5X00070G04 Analog input
  • EMERSON Ovation 5X00070G01 Analog Input Module
  • EMERSON Ovation 5X00790G01 Compact Controller Module
  • EMERSON 5X00846G01 HART analog output module
  • EMERSON 1C31113G01 Digital output module (5-60VDC)
  • EMERSON KJ4110X1-BA1 I/O terminal module
  • EMERSON CSI3125 A3125/022-020 Shaft-Vibration Monitor
  • EMERSON 5X00273G01 Digital output module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E 1-Wide I/O Carrier Extender Left
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C 1-Wide I/O Carrier Extender Right
  • EMERSON A6312/06 Speed and Key Monitor
  • EMERSON KJ4001X1-BE1 8-Wide I/O Carrier
  • EMERSON KJ2005X1-MQ1 KJ2005X1-MQ2 13P0072X082 MQ Controller
  • EMERSON 5X00226G03 - Ovation™ I/O Interface Controller, Electronics Module
  • EMERSON PR6423/00R-010+CON031 Vibration sensor
  • EMERSON 9199-00002 A6120 Control Module
  • Emerson Ovation 1C31234G01 - Ovation™ 16 Channel Compact Digital Input
  • Emerson Ovation KJ3002X1-BF1 12P1732X042 Controller module
  • Emerson Ovation 5X00226G01 I/O Interface Module
  • Emerson Ovation™ Controller Model OCR1100(5X00481G04/5X00226G04)
  • Emerson Ovation 5X00499G01 Digital Input 24Vdc Single 32CH
  • Emerson Ovation 5X00500G01 32-Channel Digital Output Module
  • Emerson ovation VE4001S2T2B4 Analog output card
  • Emerson ovation 5X00501G01 5X00502G01 Ethernet link controller
  • EMERSON A6824R 9199-00098-13 Module
  • EMERSON A6140 9199-00058 Industrial Control Module
  • EMERSON 1C31194G03 Industrial Control Module
  • EMERSON DB1-1 Industrial Control Module
  • EMERSON PMC-IO-ADAPTER I/O module
  • EMERSON L0115012 L0115032 Control module
  • EMERSON PMC-IO-PROZESSOR Process control module
  • EMERSON PMC PROFINET Manage Gigabit Ethernet switches
  • EMERSON A3120022-000 CSI3120 Bearing-Vibration Monitor
  • EMERSON SE3008 KJ2005X1-SQ1 12P6383X032 Controller
  • EMERSON 1000554 Printed circuit board
  • EMERSON PR6423/002-041 Sensor module
  • EMERSON 1C31232G02 Westinghouse control module
  • Abaco TRRM940 Switch
  • Abaco SWE440A Switch
  • Abaco NETernity™ RM984RC Ethernet Switch
  • Abaco NETernity™ GBX411 Ethernet Switch
  • Abaco NETernity™ GBX25
  • Abaco NETernity SWE540A
  • Abaco CP3-GESW8-TM8 Ethernet switch
  • Abaco SWE440S Ethernet switch
  • Abaco SWE450S 100GbE 3U VPX Switch Aligned to SOSA™ Standard
  • Abaco SWE550S 100GbE 6U VPX Switch Aligned to SOSA™ Standard
  • Abaco SPR870A Wideband Digital Receiver/Exciter
  • Abaco SPR507B Serial FPDP XMC/PMC
  • Abaco ICS-1572A Transceiver Module
  • Abaco daq8580 FMV Compression System
  • Abaco VP868 FPGA Card
  • Abaco HPC2812 Rugged 6U VPX High Performance Computer with Dual Intel
  • Abaco VSR347D 3U VPX Rugged Virtual Secure Router
  • Abaco VSR8000 Fully Rugged, COTS System Secure Router
  • Abaco RES3000 Compact, Rugged Ethernet Switches
  • Abaco PMC238 Expansion Card
  • Abaco EXP238 PMC/XMC Expansion Card for XVB603 VME Single Board Computer
  • Abaco VME-REPEAT-A-L VMEbus Repeater Link
  • Abaco VME-4514A VME Analog I/O Input/Output Board
  • Abaco VME-3128A Analog I/O
  • Abaco VME-3125A analog-to-digital Conversion board
  • Abaco VME-3123A VME Analog I/O Input Boards
  • Abaco PMC239/F Analog input/output board
  • Abaco PEX431 Multi-fabric Switch
  • Abaco CPCI-100A-BP 2-slot IndustryPack carrier for 3U CompactPCI
  • Abaco PMC522 Serial Controller
  • Abaco PMC522/FP Serial Controller
  • Abaco VME-2170A Digital Output 32-bit optically isolated
  • Abaco VME-1129 Digital Input Board 128-bit high voltage
  • Abaco IP-OCTALPLUS232 Eight EIA-232 asynchronous serial ports
  • Abaco IP-DIGITAL482 Digital I/O with 48 TTL Channels
  • Abaco PMC523 16-Port Serial Controller
  • EMERSON CE4003S2B1 M-series Traditional I/O
  • EMERSON SE3008 DeltaV™ SQ Controller
  • EMERSON 1C31227G01 - Ovation™ 8 Channel Analog Input
  • EMERSON 1C31224G01 - Ovation™ 8 Channel Analog Input
  • ABB UNS0119A-P,V101 3BHE029154P3 3BHE029153R0101 Digital input
  • ABB 3BDH000050R1 AM811F Battery Module
  • ABB 3ASC25H705-7 Digital output board
  • ABB UDD406A 3BHE041465P201 control board
  • ABB 3BHE014967R0002 UNS 2880B-P,V2: COB PCB Assembled
  • ABB PPC380AE02 HIEE300885R0102 module
  • ABB NU8976A99 HIER466665R0099 Processor Module
  • ABB DIS0006 2RAA005802A0003G Digital Input Module
  • ABB Bailey IMDS003 infi 90 Digital Output Slave Module
  • ABB XO08R1-B4.0 Expand the output relay module
  • ABB VA-MC15-05 Controller module
  • ABB VA-3180-10 Controller module
  • ABB 72395-4-0399123 Excitation module
  • ABB PU516A 3BSE032402R1 Engineering Board - PCI
  • ABB 3BHE044481R0101 3BHE044477P3 PPE091A101 Module
  • ABB UCD224A102 Control unit
  • ABB SNAT603CNT SNAT 603 CNT Motor Control Board
  • ABB SNAT634PAC Drive board
  • ABB UAD149A0011 Servo controller
  • ABB UCD224A103 Industrial controller module
  • ABB 3BHE029154P3/3BHE029153R0101 UNS0119A-P,V101 Processor Module
  • ABB ARCOL 0338 ARCOL 0346 Solid-state motor starter
  • ABB ARCOL 0339 Solid-state motor controller
  • ABB KUC720AE01 3BHB003431R0001 3BHB000652R0001 power control drive board card
  • ABB UFC718AE01 HIEE300936R0101 Main Circuit Interface Board
  • ABB 216DB61 HESG324063R100 Input/output and trip unit module
  • ABB 3HAC17973-1 DSQC332A I/O Unit
  • ABB DSQC509 Circuit board connection unit
  • ABB DSQC346B Control module
  • ABB 3HAB9271-1 Dummy Module Drive System
  • ABB 3HAC5566-1 Robot drive system cable
  • ABB 3HAC9710-1 Heat exchanger unit
  • ABB SPBLK01 Blank Faceplate
  • ABB IMFECI2 Multifunctional control board
  • ABB IMDSO14 ,Digital Slave Output Module
  • ABB 3HAC031683-004 Cable Teach Pendant 30m
  • ABB Millmate Strip Scanner Edge Sensor PMSG12x
  • ABB Millmate Controller 400 PFXA401SF
  • ABB UAC318AE Controller module
  • ABB UNS2980c-ZV4 Medium-voltage control mainboard
  • ABB 3ASC25H204 DAPU100 Control board, I/O
  • ABB 3HAB8101-19 DSQC545A Modules Drive System
  • ABB CP-E 24/1.25 Power supply
  • ABB YYT107A RECTIFIER ROBOT MODULE
  • ABB YB560100-EA S3 Teaching device
  • ABB 3BSE002253R1 TC630 AF 100 Optical Modem
  • ABB TC625 3BSE002224R1 AF100 Coaxial Modem
  • ABB TA25DU-32M Thermal Overload Relay
  • ABB SR511 Regulator 24V/5V