General product information:

Abbreviations used are: DUT: Devices Under Test (built-in modules).           KM: Kongsberg Maritime AS

Built-in modules included in this investigation are:

Modules Art. No. Description Specs

RAIV400 600370 Remote Analogue Input Voltage 24Vdc, max 0.9A power consumption. Heat

dissipation10W

RDIO420S 316564 Remote Digital Input Output 24Vdc, max 0.9A power consumption. Heat

dissipation10W

RMP420 306712 Remote Multipurpose I/O 24Vdc, 10W, Loop current max 1A per channel

RMP420S 319824 RMP420S (S version) 24Vdc, 10W, Loop current max 1A per channel

RMP422 388820 Remote Multipurpose I/O 24Vdc, 10W, Loop current max 1A per channel

RMP422S 363350 RMP422S (S version) 24Vdc, 10W, Loop current max 1A per channel

RCU502 330924 Remote Control Unit 24Vdc, 20W power consumption, 20W heat

dissipation

RSER200-4 603444 Serial Line Interface 24Vdc, 160mA

RHUB200-5 603442 RBUS Hub 24Vdc, 100mA

BUS-TERM 310955 BUS-Termination 24Vdc

RMC-TERM 346007 Remote Media Converter Termination 24Vdc

RMC-ST 321520 Remote Media Converter-ST 24Vdc, 80mA

EFI-16 321492 Earth Fault Indicator 24Vdc, max 100mA

Refer to Hardware Module Description (HMD) for comprehensive details of technical specifications

Intended use.

The built-in modules are intended for different application as parts of communication system/station. The cabinets

required for these built-in modules must have minimum IP54 rating. ‘X’-marking associated to special condition of

use is used. However safety concern was taken into account in considerations for relevant tests (e.g. thermal

endurance test).

Since external cabinet and the number of used modules at the end application are unknown, safety concern relied

on special condition of use. See ‘Condition of Use’. The internal temperatures are in any cases monitored by the

control system, e.g. internal air temperature.

Investigation of modules RMP420S & RMP422S (S-versions) is considered to be representative for modules

RMP420 & RMP422 since electronics is the same, only software may be different. The later designed module

RMP422S has multipurpose application which may/can cover the usage of several other listed modules as well.

Reset-switch and other addressable switch on a few modules may also be used only during testing/service/repair

or initializing start-up procedure of DUT where the service personnel must follow the normal safety procedures

before any service/repair work. See Special condition of use. Those switches are not used in normal operation

mode. Warning and safety precaution are provided for these switches and their application. See Copy of marking

plate.

Design.

All modules have internal transient protection except for module. RSER200-4 module is however interconnected

between other modules with internal transient protection. All modules have power dissipation approximately to or

less than 20W, therefore these built-in modules are considered as non-sparking low power equipment complying

with clause 13 of IEC60079-15: 2010. Requirements of creepage & air clearance distances are exempted. The

operating input voltage for all modules is 24Vdc, all secondary analogue and digital voltages are derived from

24Vdc input for functional purposes. Assessments are based therefore on 24Vdc as the only operating voltage.

0V reference of 24Vdc input is connected to module’s metal frame. DUT may be earthed in the end installation

and may be evaluated in the end use. Power supply with galvanic separation must be used in the end application.

Connection facilities and suitable terminals are provided. The cable lug connection may be used only during

testing or initializing start-up procedure of DUT. Cable lug is not used otherwise in normal operation mode. All

wiring is to be internal in the end installation.

General product information:

The module EFI-16 Earth Fault Indicator is used to monitor the input and output current and which indicates an

earth fault. Relay K1 on EFI-16 module is investigated for ‘nC’ requirements of IEC60079-15: 2010. Module EFI

16 is therefore evaluated for nA & nC type of protection.

Opto-couplers are used as functional separation for I/O signal of communication system. Opto-couplers have no

safety function and are treated as any other ICs due to the fact that investigation is based on requirements of

non-sparking low power equipment.

Test configuration / considerations

Built-in modules have different rated input voltage range. The output current on I/O channels are consequently

controlled & distributed so that the thermal & power aspects do not exceed the defined limits.  All channels are

short circuit protected. For high current outputs the cut-off point is by default limited to 1.08 Amp for each

channel, regardless of the supplied voltage (18 – 32VDC). Output is shutdown at input voltage less than the max

rated voltage due to this reason. Thermal condition and current are monitored and are controlled by the ma

Measurement Section, including Additional Narrative Remarks (as deemed applicable)

Clause 5.3 Maximum surface temperatures

Clause 26.5 Thermal tests. Temperatures measurements documented in Appendix B.1 of the associated

  • Hirschmann M1-8SFP Switche
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric, Solid State Protective Relay, BE1-60
  • BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator
  • BASLER ELECTRIC EXCITER DIODE MONITOR EDM-200
  • BASLER ELECTRIC DECS125-15-B2C5 DIGITAL EXCITATION CONTROL SYSTEM V 2.0.9
  • BASLER ELECTRIC BE1-851 OVERCURRENT PROTECTION RELAY MECHANISM
  • Basler Electric BE1-51A / BE151A
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler Electric BE1-87G Variable Percentage Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • BASLER ELECTRIC DECS-200-1C Digital Excitation Control System
  • Basler Electric / Kohler BE1-11g Generator Protection Relay G5A3M2J2N0E000
  • BASLER ELECTRIC DECS125-15 DIGITAL EXCITATION CONTROL SYSTEM
  • BASLER ELECTRIC BE1-951 OverCurrent Protecton System
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler Electric DGC-2020HD-5NS1DNSBA Digital Genset Controller -
  • BASLER ELECTRIC BE1-81T1EE1WA0N1F / BE181T1EE1WA0N1F
  • BASLER ELECTRIC BE1-25M1EA6PN5R1F / BE125M1EA6PN5R1F
  • BASLER ELECTRIC DECS-250-LN1SN1N DIGITAL EXCITATION CONTROL SYSTEM
  • Basler Electric DECS-250-CN2CN 1N Digital Excitation Control System Unit
  • BASLER ELECTRIC DECS-300-C0N0 DIGITAL EXCITATION CONTROL SYSTEM
  • BASLER ELECTRIC BE1-87T-A1E-A1J-D0S1F / BE187TA1EA1JD0S1F
  • BASLER ELECTRIC BE1-11-G6D1M0J2P0E000 Protection System
  • BASLER ELECTRIC BE1-GPS100-E4N1H1N GENERATOR PROTECTION SYSTEM
  • Jaquet Relay card (Auxiliary module) FTV 3090 377Z-03985
  • Jaquet Trip Chain Control card FTBU 3034 377Z-05030
  • Jaquet with input card -E04 FTFU 3024 -E04 377Z-05855
  • Jaquet with input card -E03 FTFU 3024- E03 377Z-03983
  • Jaquet FTFU 3024- E02 377Z-03982 with input card -E02
  • Jaquet  FTFU 3024-E01   377Z-03981   with input card -E01
  • Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch
  • Hirschmann BELDEN EAGLE30-04022O6TT999SCCV9HSE3F
  • Hirschmann MM3-2FXS2/2TX MICE Media Module
  • Hirschmann RS20-1600M2M2SDAPHC08.0.05 Industrial Managed Switch
  • Hirschmann OZD Profi 12M G12-1300 PRO Fieldbus Repeater
  • Hirschmann SPIDER 4TX/1FX-ST EEC Industrial Ethernet Switch
  • Hirschmann MM2-2FXM3/2TX1 MICE Media Module
  • Hirschmann RS20-2400M2M2SDAPHC09.0.14 Industrial Switch
  • Hirschmann RS20-0400M2M2SDAEHC07.1.05 OpenRail Switch
  • Hirschmann OZD Profi 12M G12-EEC Fieldbus Repeater
  • HIRSCHMANN MDA422-1/2-3.5c-23/46 sensor
  • Hirschmann RS30-2402T1T1SDAUHC Managed Industrial Switch
  • Hirschmann OZD GENIUS G12 Industrial Switche
  • Hirschmann OZD 485 G12-1300 PRO Fieldbus Repeater
  • Hirschmann MM2-2FXM2 MICE Media Module
  • Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch
  • Hirschmann MS20-0800SAAEHH04.2.04 MICE Switch
  • Hirschmann SPIDER 4TX/1FX EEC Unmanaged Industrial Switch
  • HIRSCHMANN MS4128-L3P EEC Managed Industrial Ethernet Switch
  • HIRSCHMANN RS20-0400M2T1SDAPHC08.0.01 Managed Switch
  • ETEL EA-S0M-400-40/80A-0000-00 AccurET Modular Power Supply
  • ETEL EA-B0I-0-0-0000-00 Backplane Interface Board
  • ETEL EA-P2M-400-15/40A-0100-00 Position Controller
  • ETEL EA-P2M-400-15/40A-0000-00 Position Controller
  • ETEL EA-P2M-400-10/20A-0100-01 Position Controller
  • ETEL EA-P2M-400-10/20A-0000-01 Position Controller
  • ETEL EA-P2M-400-5/10A-0100-01 Position Controller
  • ETEL EA-P2M-048-2.5/5A-0000-01 Modular Position Controller
  • ETEL EA-S0M-300-40/80A-0000-00 Power Supply Module
  • ETEL EA-P2M-300-07/15A-0100-01 Position Controller
  • ETEL EA-P2M-300-07/15A-0000-01: Modular Position Controller
  • ETEL EA-P2M-300-4/7.5A-0100-01 Overview
  • Basler Electric MOC2. Motor Operated Potentiometer
  • Basler Electric BE1-11 RTD Module, Resistance Temperature Detector
  • Basler Electric RDP-110C, Remote Display Panel
  • Basler Electric VRM-2020. Voltage Regulation Module
  • Basler Electric IDP-1500. Interactive Display Panel
  • Basler Electric AEM-2020. Analog Expansion Module
  • Basler Electric IDP-2020. Interactive Display Panel
  • Basler Electric CEM-2020. Contact Expansion Module
  • Basler Electric CEM-125. Contact Expansion Module
  • Basler Electric BE2000E, Digital Voltage Regulator
  • Basler Electric SMC-150. Synchronous Motor Controller
  • Basler Electric AVC125-10. Voltage Regulator
  • Basler Electric BE1-25. Sync-Check Relay
  • Basler Electric DGC-2020ES, Digital Genset Controller
  • ETEL EA-P2M-400-5/10A-0000-01 Position Controller
  • Basler Electric BE1-64F, Ground Fault Relay
  • Basler Electric BE1-79M, Multi Shot Reclosing Relay
  • Basler Electric BE1-81O/U, Digital Frequency Relay
  • Basler Electric BE1-87B, High Impedance Bus Differential Relay
  • Basler Electric BE1-79A, Reclosing Relay
  • Basler Electric BE1-27. BE1-59. BE1-27/59. Voltage Relay
  • Basler Electric SMC-250. Synchronous Motor Controller
  • Basler Electric SGC-250N, Synchronous Generator Controller
  • Basler Electric SGC-250. Synchronous Generator Controller
  • Basler Electric BE1-50/51 Plug and Play and Retrofit Relays
  • Basler Electric DECS-2100. Digital Excitation Control System
  • Basler Electric DECS-250E, Digital Excitation Control System
  • Basler Electric BE1-700V, Voltage Only Digital Protective Relay
  • Basler Electric DECS-250. Digital Excitation Control System
  • Basler Electric DECS-450. Digital Excitation Control System
  • Basler Electric DECS-150. Digital Excitation Control System
  • Basler Electric ES-49. Temperature Relay
  • Basler Electric ES-81O/U, ES-81O,ES-81U Overfrequency Relay
  • Basler Electric ES-74V, DC Voltage Sensing Relay
  • Basler Electric ES-27/59. Under/Overvoltage Relay
  • Basler Electric ES-27. Undervoltage Relay
  • Basler Electric ES-25. Sync-Check Relay
  • Basler Electric ES-47, ES-47N Phase Sequence Relay
  • Basler Electric ES-37.ES-37/51 Undercurrent Relay
  • Basler Electric ES-32. Reverse Power Relay
  • Basler Electric ES-59. Overvoltage Relay
  • Basler Electric ES-55. Power Factor Relay
  • Basler Electric DGC-2020HD, Digital Genset Controller
  • Basler Electric BE1-FLEX, Protection, Automation, and Control System
  • Schneider GUTOR OC0935 Power Factor Sampling Board
  • Schneider GUTOR OC0922 Analog Signal Isolation Board
  • Schneider GUTOR OC0908 Battery Voltage Detection Board
  • Schneider GUTOR OC0947 Temperature / IGBT Sampling Board
  • Schneider GUTOR OP2601 Communication Expansion Board
  • Schneider Electric GUTOR OP2312 bypass control board
  • Schneider Electric GUTOR OP2130 Cooling Fan Monitoring & Control Board
  • Schneider Electric GUTOR OP2010 Battery Test Board / Battery Management Diagnostic Card
  • Schneider Electric GUTOR OP2552 Three-phase Power Connection Board Assembly
  • Schneider Electric GUTOR OP1922A Parallel Control Board / Load-Sharing Synchronization Module
  • Schneider Electric GUTOR OP6290B Inverter Feedback Acquisition Board / Signal Scaling Module
  • Schneider GUTOR OP6280 Basic Signal Board
  • Schneider Electric GUTOR OP2456 / OP2456B Main control board
  • Schneider Electric GUTOR OP2452 Power Plug-in Panel
  • Schneider Electric GUTOR OP2450 Parallel Communication Board
  • Schneider Electric GUTOR OP2406 Interface Fuse Monitoring Board
  • Schneider Electric GUTOR OC0919 High-Power Semiconductor Module
  • Schneider Electric GUTOR OP6281A System Logic Interface Board
  • Schneider Electric GUTOR OP6285A Power Signal Acquisition Board
  • Schneider Electric GUTOR OP2438 Fan Monitor & Drive Protection Board
  • Schneider Electric GUTOR OP2446 Main Control CPU Board