DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Eaton, Moeller, Easy MFD-CP8-NT
❤ Add to collection

Eaton, Moeller, Easy MFD-CP8-NT

Eaton, Moeller, Easy MFD-CP8-NT

¥11620.00
¥8650.00
¥8650.00
¥8650.00
Weight:2.000KG
Description

Eaton, Moeller, Easy MFD-CP8-NT






Eaton, Moeller, Easy MFD-CP8-NT

DATASHEET - MFD-CP8-NT

Central processing unit/power supply unit, 24 V DC, expandable, with

easyNet, program and screen memory

Delivery program

Product range  Multi-function-display MFD-Titan

Basic function  Power supply unit/CPU modules

Subrange  CPU modules

Supply voltage  24 V DC

easyNet/easyLink  mit easyNet

Description  can be combined with display/operating unit MFD-80-.. and I/O module

Expandable: Digital/analog inputs/outputs and AS-Interface, PROFIBUS-DP,

CANopen®, DeviceNet bus systems

Bussystem easyNet optional on board

Program and screen memory

Delivery with user program possible with MFD-COMBINATION product (Article no.

201801)

Description  Program and screen memory, with easyNet

Connection type  screw terminal

Degree of Protection  IP20

Technical data

General

Standards  EN 61000-6-1/-2/-3/-4. IEC 60068-2-6. IEC 60068-2-27

Dimensions (W x H x D) mm 107.5 x 90 x 30

Weight kg 0.145

Mounting  Fitted on the fixing shaft of the display or on top-hat rail according to IEC/EN 60715.

35 mm deep (without display)

Terminal capacities

Solid mm2 0.2⁄4 (AWG 24 - 12)

Flexible with ferrule mm2 0.2⁄2.5 (AWG 24 - 12)

Standard screwdriver mm 3.5 x 0.6

Climatic environmental conditions

Operating ambient temperature °C-25 to 55. cold as per IEC 60068-2-1. heat as per IEC 60068-2-2

Condensation  Take appropriate measures to prevent condensation

Storage °C- 40 - 70

Relative humidity, non-condensing (IEC/EN 60068-2-30) % 5 - 95

Air pressure (operation) hPa 795 - 1080

Ambient conditions, mechanical

Protection type (IEC/EN 60529. EN50178. VBG 4)  IP20

Vibrations (IEC/EN 60068-2-6) Hz

Constant amplitude 0.15 mm Hz 10 - 57

Constant acceleration 2 g Hz 57 - 150

Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms Impacts 18

Drop to IEC/EN 60068-2-31 Drop height mm 50

Free fall, packaged (IEC/EN 60068-2-32) m 1

Mounting position  Vertical or horizontal

Electromagnetic compatibility (EMC)

Electrostatic discharge (IEC/EN 61000-4-2. Level 3. ESD) kV

Air discharge kV 8

Contact discharge kV 6

Electromagnetic fields (RFI) to IEC EN 61000-4-3 V/m 10

Radio interference suppression  EN 55011 Class B, EN 55022 Class B

Burst Impulse (IEC/EN 61000-4-4. Level 3)

Supply cable kV 2

Signal lines kV 2

Power pulses (surge) (IEC/EN 61000-4-5) kV 2 (supply cables, symmetrical)

power pulses (surge) (IEC/EN 61000-4-5. level 2) kV 2 (supply cables symmetrical, MFD-AC-CP8..)

Immunity to line-conducted interference to (IEC/EN 61000-4-6) V 10

Insulation resistance

Clearance in air and creepage distances  EN 50178. UL 508. CSA C22.2. No. 142

Insulation resistance  EN 50178

Back-up of real-time clock

Back-up of real-time clock

① Backup time (hours) with fully charged double layer capacitor

② Service life (years)

Accuracy of the real-time clock s/day Normally ±5 s/day (±0.5 h⁄year)

Repetition accuracy of timing relays

Accuracy of timing relays (of values) % ± 0.02

Resolution

Range “S” ms 5

Range “M:S” s 1

Range “H:M” min 1

Retentive memory

Write cycles of the retentive memory  1010 (read/write cycles)

Power supply

Rated operational voltage Ue V 24 DC (-15⁄+20 %)

Admissible range V DC 20.4 - 28.8

Residual ripple % ≦ 5

Input current

at 24 V DC mA Normally 200

Voltage dips ms 10

Power loss

Heat dissipation at 24 V DC W 3.4

Note on heat dissipation  Current consumption at 24 V DC

Network easyNet

Stations Number max. 8

Data transfer rate/distance  1000 kBit/s, 6 m

500 Kbit/s, 25 m

250 Kbit/s, 40 m

125 kBit/s, 125 m

50 Kbit/s, 300 m

20 Kbit/s, 700 m

10 Kbit/s, 1000 m

Distance m 5

Potential isolation

From power supply  yes

From the inputs  yes

From the outputs  yes

to PC interface, memory card, easyNet, easyLink  yes

Bus termination (first and last station)  yes

Connection technique  RJ45. 8-pole

Design verification as per IEC/EN 61439

Technical data for design verification

Rated operational current for specified heat dissipation In A 0

Heat dissipation per pole, current-dependent Pvid W 0

Equipment heat dissipation, current-dependent Pvid W 0

Static heat dissipation, non-current-dependent Pvs W 3.4

Heat dissipation capacity Pdiss W 0

Operating ambient temperature min. °C-25


  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671