DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Eaton HMCP400R5 Circuit Breaker
❤ Add to collection

Eaton HMCP400R5 Circuit Breaker

Eaton HMCP400R5 Circuit Breaker

¥10620.00
¥8540.00
¥8540.00
¥8540.00
Weight:2.000KG
Description

Eaton HMCP400R5 Circuit Breaker






Application of multi-wire terminals

for molded case circuit breakers

Abstract

Multi-wire terminals for molded case circuit

breakers are a means to provide more than one

load side termination while maintaining the circuit

breaker’s ULT listing. This paper examines the

application of multi-wire terminals in conjunction

with UL Standard 508A as well as with the National

Electrical CodeT, NFPAT 70-2014 (NECT). The paper

addresses multi-wire terminals used with circuit

breakers in industrial control panels as defined in

NEC Section 409 and UL Standard 508A.

Codes and standards requirements

NEC requirements

NEC Section 430.28 addresses the topic of feeder taps.

430.28 Feeder Taps—Feeder tap conductors shall have an ampacity

not less than that required by Part II (Part II addresses the sizing

of conductors for specific loads; consult the NEC for details), shall

terminate in a branch-circuit protective device, and, in addition, shall

meet one of the following requirements:

Be enclosed either by an enclosed controller or by a raceway,

be not more than 10 feet (3 m) in length, and, for field

installation, be protected by an overcurrent device on the line

side of the tap conductor, the rating or setting of which shall not

exceed 1000 percent of the tap conductor ampacity.

2. Have an ampacity of at least 1/3 that of the feeder conductors,

be suitably protected from physical damage or enclosed in a

raceway, and be not more than 25 feet (7.5 m) in length.

3. Have an ampacity not less than the feeder conductors

[Reference 1].

UL 508A requirements

UL 508A Section 31.4 addresses the issue using similar

language.

KOLLMORGENCR06200-000000
KOLLMORGENDIGIFAS7201
KOLLMORGENE33NRHA-LNN-NS-00
KOLLMORGENS20330-SRS
KOLLMORGENS20360-SRS
KOLLMORGENS22460-SRS
KollmorgenS30301-NA SERVOSTAR 343
KOLLMORGENS70602-NANANA
KOLLMORGENSAM-DA-400-07B-P4N-F
KOLLMORGENSERVOSTAR 310
KONGSBERG8100183
KONGSBERGMRU-5-1
KONGSBERGMRU-E-JB1
KONGSBERGMRU-M-MB2
KONGSBERGMRU-M-MB3
KONGSBERGMRU-M-SU1

Section 31.4.3—The ampacity of the tap conductors, the internal

conductors to the individual loads, shall be:

A. Not less than 1/3 the ampacity of the branch circuit conductor,

calculated as in 28.3.3 (28.3.3 addresses the sizing of field-wiring

conductors for specific loads. Consult UL 508A for details.); or

B. Not less than 1/10 the ampere rating of the branch circuit

protection for the group for each motor circuit provided with

a manual motor controller marked “Suitable as tap conductor

protection in group installations” and complies with the Standard

for Industrial Control Equipment, UL 508. The conductors on the

load side of the manual motor controller shall have an ampacity

not less than calculated in 28.3.2 (28.3.2 addresses the sizing

of field-wiring conductors for motor loads; consult UL 508A for

details) [Reference 2].

NEC 430.28 (1) and UL 508A 31.4.3 (b) state the same requirement

in different terms. Both agree, however, that a tap conductor no more

than 10 feet (3 m) long, emanating from a multi-wire terminal (tap),

must have an ampacity equal to at least 10 percent of the ampacity

of the feeder breaker’s trip current. Some term this the 10-foot

tap rule.

Likewise, NEC 430.28 (2) and UL 508A 31.4.3 (a) state the same

requirement for tap conductors up to 25 feet (7.5 m) long, sometimes

termed the 25-foot tap rule. A tap conductor up to 25 feet (7.5 m)

long must have an ampacity equal to at least 1/3 the ampacity of

the feeder breaker’s trip current.

Sizing conductors

Application complying with UL 508A

10-foot tap rule

The ampacity for a tap conductor applied to a 200 A circuit breaker

must be equal to 20 A or greater. Referring to Table 28.1 in UL 508A,

the conductor would have to be at least 12 AWG. The conductor must

terminate in an appropriately sized overcurrent protective device,

for example, a circuit breaker or fuse.

25-foot tap rule

The ampacity for a conductor not exceeding 25 feet (7.5 m) in length

must be at least 1/3 the ampacity of the circuit breaker’s trip rating.

The ampacity for a tap conductor applied to a 300 A circuit breaker

must be equal to 100 A or greater. Referring to Table 28.1

in UL 508A, the conductor would have to be at least 3 AWG.

The conductor must terminate in an appropriately sized overcurrent

protective device, for example, a circuit breaker or fuse.

Size range of conductors

While a wide range of conductors is listed for a particular multi-wire

terminal, the entire range may not apply to every breaker frame to

which a terminal is affixed. A K-frame breaker, for example, can have

trip ranges from 70 A to 40 A. While a 14 AWG conductor may be

applied to a 70 A trip unit, it may not be applied to a 400 A trip unit.

Proper selection must be made as noted in the rules elucidated in

the application sections above.

Conductor temperature ratings

Circuit breaker terminals are rated for a maximum temperature of

75 °C. Attention must be paid to conductor temperature ratings and

the corresponding ampacities tabulated in the appropriate standard.

Table 28.1. UL 508A, contains columns for conductor temperatures

of 60 °C and 75 °C. Either is within the range of the multi-wire

terminal temperature rating.

While NEC Table 310.15 (b) (16) contains like ratings, it also contains

columns for 90 °C and higher. Conductors having higher temperature

ratings, such as 90 °C, may be used; however, the ampacity must be

de-rated to that in the 75 °C column.



  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671