DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

Summary of Advant Controller 160

From:ABB | Author:LIAO | Time :2025-08-07 | 154 Browse: | Share:

# Advant® OCS Open Control System ## Advant Controller 160 Advant Controller 160, installed with two I/O tiers in one cabinet (I/O connections in the adjacent cabinet).   The scalable controller for complex applications   The Advant Controller 160 is the most modern in the Advant Controller 100 series. This scalable device, which boasts numerous control and communication functions, was developed for a wide range of industrial applications: for small to medium-sized plants, for logical controls and control loops, as a stand-alone device or integrated into the Advant OCS process control system.   The ability to configure all central components redundantly ensures an overall stable system. The scalability with up to 6 controllers per tier is ideal for meeting almost any performance requirement.   ## Advant Controller 160: - Masters logical sequence controls as well as control loops, counting and arithmetic functions. It supports real sequential event recording through the time stamping of events received via input modules with a resolution of 1 ms.   - Features an RS 232 interface for connection to MODBUS I or for communication with decentralized terminals.   - Offers a PROFIBUS-DP interface to support a wide range of applications in manufacturing, process and power plant automation. Manufacturer independence and openness are guaranteed by the PROFIBUS standard EN 50170.   - Is designed for both independent and decentralized systems and can be used either as a stand-alone device or in conjunction with other components of the Advant OCS process control system.   - With 31 independent tasks whose execution times (minimum 2 ms) can be freely defined by the user, the Advant Controller 160 delivers strong processing performance.   - Is a future-proof device as it can be expanded in various ways and programmed online.   - Is programmed in AMPL via the Advant Station 100 Engineering Station.   - Stores application programs in a non-volatile memory without battery buffering. The program memory can be electrically erased and thus is immediately reprogrammable.   - Provides password protection against unauthorized access.   ## ABB Advant Controller 160 – when availability matters Advant Controller 160 with redundant central units and a central unit for the MVI interface   ## Expandable for all plants   The Advant Controller 160 can be expanded and modified in various ways, making it particularly well-suited to adapt to changing plant conditions. The simplest solution in this context is the addition of I/O modules; this process can be carried out online, i.e., without switching off the controller. The Advant Controller 160 can also be expanded by adding additional I/O tiers. A third option is to connect multiple Advant Controller 160 stations to a decentralized system via the high-performance Advant Fieldbus 100; in this way, up to 80 stations can be interconnected. To meet even the most demanding reliability criteria, the Advant Fieldbus 100 can be fully redundantly wired and equipped with redundant interfaces.   Both coaxial and twisted-pair bus cables are available for selection to achieve different bus lengths. Fiber-optic cables and modems provide protection against electromagnetic interference.   ## Open communication   It is now easier than ever to combine Advant control systems with OPC-compatible software of your choice. Available visualization systems from ABB include, for example, AdvaSoft for Windows or SattGraph 5000.   The Advant OPC Server, which is based on Windows NT, provides powerful, easy-to-use services for reading, writing and subscribing to data. Thus, it is simple to implement a wide variety of applications for the control and monitoring of production processes. The Advant OPC Server software gives applications that support the OPC standard access to real-time process and production data in ABB Advant control systems. The Advant OPC Server for Advant Fieldbus 100 can coexist with other Windows NT-based configuration tools, such as AMPL Control Configuration. This combination offers, among other things, the possibility of configuration via networks and troubleshooting for nodes on the Advant Fieldbus 100. This means you can configure, commission and maintain all your stations in the control system from a central point – with a minimum of effort.   ## Everything is correct, including the system connections ...   As part of the Advant OCS automation system, the Advant Controller 160 communicates with the system via the Advant Fieldbus 100. Since it can be networked with third-party systems via serial interfaces, the controller is the ideal medium for integrating PLC components into process and plant control systems.   ## System configuration shows various communication possibilities of the Advant Controller 160   ## ... and the reliability of the system   For use in complex control engineering applications, all essential functions of the station can be configured redundantly, including data processing, power supply, interfaces to the Advant Fieldbus 100 and I/O bus extensions. Switching to other devices, even to other central units, is completely seamless and transparent.   ## Graphical application development   The Advant Controller 160 is configured with the Function Chart Builder function plan editor in AMPL. AMPL is the uniform configuration and programming language for graphic applications used throughout the Advant OCS process control system in conjunction with the master software, and handles logical links, arithmetic functions and continuous control tasks equally well. Application programs are developed graphically page by page by selecting the appropriate function blocks and connecting them internally and to the process.   Application programs look the same on paper as they do on the screen, which can be particularly advantageous for troubleshooting: the printout provides an overview, and the screen delivers the details. In addition, signal values can be updated during operation   and configured signals can be traced back to their source.   ## Optimal process connections   To establish digital and analog inputs and outputs, various I/O modules of the S600 series can be connected to the Advant Controller 160. The I/O area is designed for both alternating current and direct current and is equally suitable for inexpensive modules with high signal density as well as for high-performance modules with kV isolation. Also available is an intelligent pulse counter module for precise length measurement and positioning, which can process pulse frequencies of up to 100 kHz. In addition, a speed input module with integrated shutdown logic, which is used to control turbines and other rotating machines, can be connected to the system.   All S600 I/O modules are enclosed in a sheet metal housing (protection class IP20) to provide protection against electromagnetic interference in the tier and against mechanical damage from the outside. Field cables are connected via terminals to a plug contact strip that is plugged onto the front of the module – a space-saving and clean solution. Distributed input/output devices of the S800 I/O series can be coupled to the Advant Fieldbus 100. You can install up to 32 such input/output devices.   ## Technical Information   ### Alternative power supply   Digital inputs 24 V DC - 32 channels, non-isolated (DI610) - 32 channels, isolated in four groups (DI620)   - 32 channels, isolated in four groups (DI650)   48 V DC   Direct (input non-isolated)   19.2-30 V DC 33 MHz 3.0 MB 33 MHz 3.5 MB max. 125 Slaves max. 12 MBit/sec.   DC (input isolated) 110-125/220-250 V DC   AC (input isolated) 110/120/220/240 V, 47-450 Hz   ### Basic performance features   Central unit PM 640 and PM 644: (Supports SC 610)   - 32 channels, isolated in four groups (DI621)   - 32 channels, isolated in four groups (DI651)   60 V DC - 32 channels, isolated in four groups (DI622)   - 32 channels, isolated in four groups (DI652)   120 V AC   Clock frequency:   Program memory, Flash-PROM   Central unit PM 645A: (redundant processing)   Clock frequency:   Program memory, Flash-PROM   PROFIBUS-DP Interface (PM644)   Bit rate   - 16 channels, isolated in four groups (DI635) 230 V AC   ### Basic communication connections   - 16 channels, isolated in four groups (DI636) Digital outputs 24 V DC   PM 640:   RS 232C for Advant Engineering Station 100   RS 232C interface for MODBUS I   PM 645A:   - 32 channels, max 200 mA, short-circuit proof, non-isolated (DO610)   RS 232C for Advant Engineering Station 100   RS 232C interface for MODBUS I   - 16 channels, max 2.4 A, short-circuit proof, isolated in 8 groups (DO625) < 60 V DC   RS-422 (fast serial connections)   - 32 channels, max 0.5 A, short-circuit proof, isolated in four groups (DO620) 24...250 V AC/DC   Integrated majority voting (redundancy management)   Total I/O performance   max. 1,500 max. 75 max. 7 max. 2 max. 10   - 16 channels (relay). Load current: max. 2 A, min. 20 mA. Switching capacity: AC: 500 VA, DC: 40 W (DO630) Pulse counting <100 kHz, 5 or 24 V or ±13 mA DC - 5 counters, each with 2 inputs, 1 strobe and 1 set (24 V only) inputs, each input individually optically isolated. Counting modes: up, down, frequency, differential, position, speed measurement   ### Hardware options   Advant Fieldbus 100 redundant, coaxial cable,   two CI630   Advant Fieldbus 100 (AF 100) redundant, coaxial cable,   one CI630   CI631 for subordinate, redundant AF 100 and S800   I/O connection max. 1 redundant pair   Interface module carrier SC610   Supports communication protocols RCOM/RCOM+ and   - RCOM/RCOM+ interface, CI532V01, 2 channels   - MODBUS I interface, CI532V02, 2 channels   - Siemens 3964R, CI532V03, 2 channels   Event handling on digital input modules   DI650/DI651/DI652, Advant Fieldbus 100, and/or RCOM/RCOM+.   ### Analog inputs   0...20mA   - 32 channels, unipolar, 12-bit resolution (AI610)   - 16 channels, isolated as a group, 12-bit resolution, CMR=50V, (CMRR >100 dB) (AI625)   ±10V/ ±20 mA   - 16 channels, differential, 12-bit resolution, CMV=100V,   CMRR >80 dB (at 16, 33, 50 or 60 Hz) (AI620)   Pt100 or resistance   - 12 channels, -200...600°C or 0...500Ω, 0.5 V, 3- or 4-wire, isolated as a group, 13-bit resolution, CMRR>100dB (AI630)   ### Thermocouples   - 14 measuring + 2 reference channels, measuring range C and J, isolated as a group, 12-bit resolution,   CMRR >120 dB (AI635)   ### Analog outputs   0…20mA   - 16 channels, isolated as a group, 12-bit resolution (AO610)   ±10V/ ±20 mA, 4-20 mA, 0-5V, 0-10V, 1-5 V   - 8 channels, individually isolated, 12-bit resolution (AO650)   ### Notes   1 For details on the Advant Controller 160, see the manual on Advant OCS. 2 The CI532Vxx module is plugged into an SC610 module. Central unit PM640 required. 3 A practical (i.e., not an ultimate theoretical) limit.   4 With event detection (time stamping) or pulse acquisition functionalities.   5 Can be installed in the enclosures of various cabinets. 6 Corresponds to NEMA protection classes 1, 2 and 5. 7 Specific specifications for slot allocation. 8 Termination of unused monitored analog input required. 9 Standard version. 10 Extended version, with second AF 100.  

  • EMERSON MVME61006E-0163R VMEbus Single-Board Computer
  • EMERSON Ovation 5X00453G01 Remote I/O Node Controller Module
  • EMERSON 5X00070G04 Analog input
  • EMERSON Ovation 5X00070G01 Analog Input Module
  • EMERSON Ovation 5X00790G01 Compact Controller Module
  • EMERSON 5X00846G01 HART analog output module
  • EMERSON 1C31113G01 Digital output module (5-60VDC)
  • EMERSON KJ4110X1-BA1 I/O terminal module
  • EMERSON CSI3125 A3125/022-020 Shaft-Vibration Monitor
  • EMERSON 5X00273G01 Digital output module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E 1-Wide I/O Carrier Extender Left
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C 1-Wide I/O Carrier Extender Right
  • EMERSON A6312/06 Speed and Key Monitor
  • EMERSON KJ4001X1-BE1 8-Wide I/O Carrier
  • EMERSON KJ2005X1-MQ1 KJ2005X1-MQ2 13P0072X082 MQ Controller
  • EMERSON 5X00226G03 - Ovation™ I/O Interface Controller, Electronics Module
  • EMERSON PR6423/00R-010+CON031 Vibration sensor
  • EMERSON 9199-00002 A6120 Control Module
  • Emerson Ovation 1C31234G01 - Ovation™ 16 Channel Compact Digital Input
  • Emerson Ovation KJ3002X1-BF1 12P1732X042 Controller module
  • Emerson Ovation 5X00226G01 I/O Interface Module
  • Emerson Ovation™ Controller Model OCR1100(5X00481G04/5X00226G04)
  • Emerson Ovation 5X00499G01 Digital Input 24Vdc Single 32CH
  • Emerson Ovation 5X00500G01 32-Channel Digital Output Module
  • Emerson ovation VE4001S2T2B4 Analog output card
  • Emerson ovation 5X00501G01 5X00502G01 Ethernet link controller
  • EMERSON A6824R 9199-00098-13 Module
  • EMERSON A6140 9199-00058 Industrial Control Module
  • EMERSON 1C31194G03 Industrial Control Module
  • EMERSON DB1-1 Industrial Control Module
  • EMERSON PMC-IO-ADAPTER I/O module
  • EMERSON L0115012 L0115032 Control module
  • EMERSON PMC-IO-PROZESSOR Process control module
  • EMERSON PMC PROFINET Manage Gigabit Ethernet switches
  • EMERSON A3120022-000 CSI3120 Bearing-Vibration Monitor
  • EMERSON SE3008 KJ2005X1-SQ1 12P6383X032 Controller
  • EMERSON 1000554 Printed circuit board
  • EMERSON PR6423/002-041 Sensor module
  • EMERSON 1C31232G02 Westinghouse control module
  • Abaco TRRM940 Switch
  • Abaco SWE440A Switch
  • Abaco NETernity™ RM984RC Ethernet Switch
  • Abaco NETernity™ GBX411 Ethernet Switch
  • Abaco NETernity™ GBX25
  • Abaco NETernity SWE540A
  • Abaco CP3-GESW8-TM8 Ethernet switch
  • Abaco SWE440S Ethernet switch
  • Abaco SWE450S 100GbE 3U VPX Switch Aligned to SOSA™ Standard
  • Abaco SWE550S 100GbE 6U VPX Switch Aligned to SOSA™ Standard
  • Abaco SPR870A Wideband Digital Receiver/Exciter
  • Abaco SPR507B Serial FPDP XMC/PMC
  • Abaco ICS-1572A Transceiver Module
  • Abaco daq8580 FMV Compression System
  • Abaco VP868 FPGA Card
  • Abaco HPC2812 Rugged 6U VPX High Performance Computer with Dual Intel
  • Abaco VSR347D 3U VPX Rugged Virtual Secure Router
  • Abaco VSR8000 Fully Rugged, COTS System Secure Router
  • Abaco RES3000 Compact, Rugged Ethernet Switches
  • Abaco PMC238 Expansion Card
  • Abaco EXP238 PMC/XMC Expansion Card for XVB603 VME Single Board Computer
  • Abaco VME-REPEAT-A-L VMEbus Repeater Link
  • Abaco VME-4514A VME Analog I/O Input/Output Board
  • Abaco VME-3128A Analog I/O
  • Abaco VME-3125A analog-to-digital Conversion board
  • Abaco VME-3123A VME Analog I/O Input Boards
  • Abaco PMC239/F Analog input/output board
  • Abaco PEX431 Multi-fabric Switch
  • Abaco CPCI-100A-BP 2-slot IndustryPack carrier for 3U CompactPCI
  • Abaco PMC522 Serial Controller
  • Abaco PMC522/FP Serial Controller
  • Abaco VME-2170A Digital Output 32-bit optically isolated
  • Abaco VME-1129 Digital Input Board 128-bit high voltage
  • Abaco IP-OCTALPLUS232 Eight EIA-232 asynchronous serial ports
  • Abaco IP-DIGITAL482 Digital I/O with 48 TTL Channels
  • Abaco PMC523 16-Port Serial Controller
  • EMERSON CE4003S2B1 M-series Traditional I/O
  • EMERSON SE3008 DeltaV™ SQ Controller
  • EMERSON 1C31227G01 - Ovation™ 8 Channel Analog Input
  • EMERSON 1C31224G01 - Ovation™ 8 Channel Analog Input
  • ABB UNS0119A-P,V101 3BHE029154P3 3BHE029153R0101 Digital input
  • ABB 3BDH000050R1 AM811F Battery Module
  • ABB 3ASC25H705-7 Digital output board
  • ABB UDD406A 3BHE041465P201 control board
  • ABB 3BHE014967R0002 UNS 2880B-P,V2: COB PCB Assembled
  • ABB PPC380AE02 HIEE300885R0102 module
  • ABB NU8976A99 HIER466665R0099 Processor Module
  • ABB DIS0006 2RAA005802A0003G Digital Input Module
  • ABB Bailey IMDS003 infi 90 Digital Output Slave Module
  • ABB XO08R1-B4.0 Expand the output relay module
  • ABB VA-MC15-05 Controller module
  • ABB VA-3180-10 Controller module
  • ABB 72395-4-0399123 Excitation module
  • ABB PU516A 3BSE032402R1 Engineering Board - PCI
  • ABB 3BHE044481R0101 3BHE044477P3 PPE091A101 Module
  • ABB UCD224A102 Control unit
  • ABB SNAT603CNT SNAT 603 CNT Motor Control Board
  • ABB SNAT634PAC Drive board
  • ABB UAD149A0011 Servo controller
  • ABB UCD224A103 Industrial controller module
  • ABB 3BHE029154P3/3BHE029153R0101 UNS0119A-P,V101 Processor Module
  • ABB ARCOL 0338 ARCOL 0346 Solid-state motor starter
  • ABB ARCOL 0339 Solid-state motor controller
  • ABB KUC720AE01 3BHB003431R0001 3BHB000652R0001 power control drive board card
  • ABB UFC718AE01 HIEE300936R0101 Main Circuit Interface Board
  • ABB 216DB61 HESG324063R100 Input/output and trip unit module
  • ABB 3HAC17973-1 DSQC332A I/O Unit
  • ABB DSQC509 Circuit board connection unit
  • ABB DSQC346B Control module
  • ABB 3HAB9271-1 Dummy Module Drive System
  • ABB 3HAC5566-1 Robot drive system cable
  • ABB 3HAC9710-1 Heat exchanger unit
  • ABB SPBLK01 Blank Faceplate
  • ABB IMFECI2 Multifunctional control board
  • ABB IMDSO14 ,Digital Slave Output Module
  • ABB 3HAC031683-004 Cable Teach Pendant 30m
  • ABB Millmate Strip Scanner Edge Sensor PMSG12x
  • ABB Millmate Controller 400 PFXA401SF
  • ABB UAC318AE Controller module
  • ABB UNS2980c-ZV4 Medium-voltage control mainboard
  • ABB 3ASC25H204 DAPU100 Control board, I/O
  • ABB 3HAB8101-19 DSQC545A Modules Drive System
  • ABB CP-E 24/1.25 Power supply
  • ABB YYT107A RECTIFIER ROBOT MODULE
  • ABB YB560100-EA S3 Teaching device
  • ABB 3BSE002253R1 TC630 AF 100 Optical Modem
  • ABB TC625 3BSE002224R1 AF100 Coaxial Modem
  • ABB TA25DU-32M Thermal Overload Relay
  • ABB SR511 Regulator 24V/5V