DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
EMERSON  KJ4001X1-BE1 8-Wide I/O Carrier
❤ Add to collection

EMERSON KJ4001X1-BE1 8-Wide I/O Carrier

EMERSON  KJ4001X1-BE1 8-Wide I/O Carrier

26444.00
¥61456.00
¥61456.00
¥61456.00
Weight:7.000KG
Description

EMERSON  KJ4001X1-BE1 8-Wide I/O Carrier


KJ4001X1-BE1 8-Wide I/O Carrier

Hazardous Atmosphere 

3G Ex ec IIC Gc 

FM16ATEX0056U

 FM21UKEX0017U 

CL. I Div. 2 GP. A,B,C,D

 CL. I Zone 2 AEx/Ex ec IIC Gc

 FM17US0286U

 FM17CA0145U

 Power Specifications 

Local Bus Power 

Bussed field Power 

12.6 VDC at 8 A 

30 VDC at 6.5 A 

Environmental Specifications 

Ambient 

Temperature 

Shock 

Vibration 

Airborne 

Contaminants 

Relative Humidity -40°C to +70°C

 10g ½ Sinewave for 11msec 

1mm Peak to Peak from 2 to 13.2Hz; 

0.7g from 13.2 to 150Hz 

ISA-S71.04 –1985 Airborne 

Contaminants Class G3 

5 to 95% Non-Condensing 

Note: Refer to the product label for serial number 

and location and date of manufacture.  

Warning: This product has specific instructions for 

installation, removal and operation in hazardous 

areas. Refer to document 12P2046 "DeltaV™ 

Scalable Process System Zone 2 Installation 

Instructions".  Other installation instructions are 

available in the "DeltaV™ M-Series Hardware 

Installation and Reference" manual.   

Removal and Insertion 

This unit cannot be removed or inserted with system 

power energized. Power must be de-energized 

before disconnecting any carriers or LocalBus 

Extender cables.  

Bussed field power must not be connected to a 

supply that generates or contains a source of 

potential in excess of 30 VDC. 

Field power supplied to this device either at the field 

terminal or as bussed field power via the I/O carrier 

must be removed before removing or connecting this 

device. 

A module cover (KJ4001X1-FA1) must be fitted to 

any permanently unoccupied location on a carrier. 

(Permanently unoccupied implies no I/O card is 

intended for that location.) 

No combination of I/O carriers and LocalBus 

Extenders must exceed a length of 6.5 meters. 

Interconnecting cable between enclosures must be 

in conduit. 

Maintenance and Adjustment 

This unit contains no user serviceable parts and 

should not be disassembled for any reason. 

Calibration is not required.

EMERSON Power One   WH5-2FF Ovation Power Supply Module 24VDC 12A/8A Output New
EMERSON WM 2150 DRIVE HP RATING: 5.0 UNMP
Emerson Fisher-Rosemount DeltaV   KJ3243X1-BB2 Profibus DP Interface Card 2 Plus
1PC NEW EMERSON Inverter SP2403 Via DHL /   FedEX
1PC NEW EMERSON Inverter SP4402 Via DHL /   FedEX

EMERSON 392594-01-3 / 392594013
NEW EMERSON NIDEC M200-05400270A Inverter
EMERSON 275-D9EI0C0000 / 275D9EI0C0000
1PC NEW EMERSON Inverter ES3401 Via DHL /   FedEX
Control Techniques Emerson M702-034 00062   A Unidrive NEW In Stock!
Surplus Emerson KJ2005X1-MQ1 Controller   Module
Emerson Rosemount 3900-01-10 Ph Sensor
 NEW Emerson Nidec SKBD200110 Inverter 
 NEW Emerson Nidec SK3403 Inverter 
LOT OF 6 EMERSON ST DST1402 3098-0015   8.1APK 250MS CONTROL TECHNIQUES SERVO DRIV
NIB Emerson Delta V KJ1501X1-BC3 VE5009   Power Supply Original Sealed Static Bag
Emerson 6A00275G02 Hastelloy Diffuser Kit
EMERSON聽IC695CPE330 RX3i 1GHz 64MB CPU   w/ETHERNET
EMERSON 10P57520007 / 10P57520007
AMK Amkasyn AW 25/38-3 Servo Inverter   Module New Sealed


  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200
  • ABB PCS6000 medium voltage wind turbine converter
  • SYSTEM DRIVES PCS6000 ABB
  • ABB PP886 Compact Product Suite hardware selector
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Panel 800 Version 6- PP885
  • ABB IndustrialIT Panel 800 - PP846 Version 5.1
  • ABB IndustrialIT Panel 800 - PP836 Version 5.1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • ABB Advant® Master S100 I/O system
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • GE Reason RT431 GPS Precision-Time Clock
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany (2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • Advant™Automation with MOD 300™ Software
  • ABB MEASUREMENT & ANALYTICS EasyLine EL3000 / EL3060
  • ABB MEASUREMENT & ANALYTICS PGC5000 Process gas chromatograph