RCU501 is a high performance, general purpose, real-time process control computer for use in a
wide variety of system applications in both on- and offshore installations. The processor core is
an embedded Power PC™ architecture and the module is approved for Ex Zone 2 applications.
Application types
• Dynamic Positioning Systems
• Thruster Control / Steering Systems
• Navigation Sensor Integrator
• Integrated Process Control Systems
• Alarm and monitoring Systems
• Safety Systems
Function
• Dual ethernet LAN process networks
• Dual RedundancyNet interface for
redundant RCU confi guration
• Dual Remote IO process BUS (RBUS)
• 4 general purpose Digital Input channels
• 4 general purpose Digital Output
channels
• 32 serial lines for 3rd party interface
• 2 PROFIBUS channels for 3rd party
interface
• 2 CANBUS channels for 3rd party
interface
Feature
• Single unit topology: SIL 1 compliant
• Dual unit topology: SIL 2 and SIL 3
compliant
• Triple unit topology
• Ex Zone 2 approved
• Compliant to the following protocols:
1. Modbus (Serial and TCP)
2. NMEA 0183
3. PROFIBUS/PROFIsafe
4. CAN/DeviceNet
• 3rd party vendor specifi c protocols are
available upon request
• Power:
1. Redundant power input with power
alarm monitoring
2. Inrush current and over-voltage
protection
• Enhanced watchdog with fail-safe
function and system status output
Benefi ts
The following built-in functions
minimize system downtime:
• Extended Built-in Self- Test (BIST)
for computer diagnostics and fault
identifi cation during start-up and runtime
• Prepared for online remote diagnostics
• Prepared for online fi rmware upgrade
• Bootable from fi le server or local fl ash
memory
• Easy installation and replacement
1. DIN Rail mounting
2. All connections are pluggable
3. 3 digit address switches
• Hot swap in redundant applications,
dual and triple Hot-Standby redundancy,
1oo2 redundancy
• Status LED indication (Normal/Error)
• RoHS compliant
Computer performance
• RCU501 performance is application
dependant and governed by process
complexity, updating frequency and
number of interfaced I/O. Maximum
updating frequency is 50 Hz.
• Confi guration guidelines:
1. ESD/PSD: max. 800 I/O,
F&G: max. 700 I/O
both at scan rate: 1 Hz
2. Process/ Automation:
max. 2000 I/O,
design advice: 1280 I/O
both at scan rate: 1 Hz
3. Anti-surge: 3 loops, Scan rate: 50 Hz
4. Dynamic Positioning: Triple
redundant DP system combined
with Position Mooring. (Scan rate
is adapted to signal processing and
varies from 1 to 10 Hz).
KM article number
RCU501: 603439
Standards
RCU501 complies with the following:
• IACS E10
• IEC 60533
• IEC 60945
• IEC 61508
• IEC 62061
Type approval
RCU501 is type approved by:
• Det Norske Veritas (DNV)
• The American Bureau of Shipping
(ABS)
• TÜV Rheinland
• Wurldtech™; Achilles level 1
certifi ed
CE marking
CE mark compliant, confi rm to:
• 2004/108/EC (EMC directive)
• 94/9/EC (Atex directive)
Ex certifi cation
Ex nA II T4 (Zone 2)
Environmental
specifi cations
Ambient temperatures and humidity:
• Temp. Operation: -15˚C to 70˚C
• Temp. Storage: -25˚C to 70˚C
• Humidity Operation: Up to 98% RH
• Humidity Storage: Up to 98% RH
Protection Standards: IP 20
Dimensions
Height: 355 mm
Width: 158 mm
Depth: 87 mm
Weight: 1.35 kg
Cross point screw lock on DIN Rail T35
7.5/15 according to EN 50022
Electrical
Input supply voltage: 24 VDC
(+30%, -25%)
Nominal current consumption: ≈ 0.8 A
Start-up current: Max. 2.7 A
Power consumption: Max. 20 W
Heat dissipation: Max. 20 W
Power connectors:
• Screw terminals (slotted)
• Cable cross section: 2.5 mm²
Processor and memory
Processor:
• Type: Power PCTM host processor
MPC8245
• Clock frequency: 400 MHz
Memory:
• RAM size and speed: 64 MB @ 133
MHz
• PROM: 16 MB application fl ash-fi le
Serial line
Channels: 32 insulated serial lines,
distributed on 8 RJ45 connectors
Physical layer: RS232, RS422 and
RS485 Multidrop via RSER200
Bit rate: Max. 115 kb/s
General purpose I/O
channels
Digital Output (DO):
• 4 x opto-isolated outputs
• 1 x opto-isolated watchdog (for
external interface)
Digital Input (DI): 4 x opto-isolated
inputs
I/O connectors:
• Cage clamps
• Cable cross section: 1 mm²
LAN interface
Process network & RedundancyNet:
2 x RJ45 Ethernet IEEE 802.3 type
10BASE-T/100BASE-TX
RBUS interface
Connector: 2 x RJ45
Bit-rate: 2 Mb/s
Signal code: Manchester encoded
(Self-clocked)
Copper wire topology:
• Insulation: 500 V (Optocoupler)
• Physical layer: RS485 Multidrop
• Cable attenuation: < 6.5 db/100m @
10 MHz (CAT 5)
• Cable length: Max. 200 m between
repeaters. Max. 3 repeaters
Fibre optical topology (w/ additional
fi bre media converter):
• Fibre cable: 62.5/125 μm. Multimodus
• Connector: ST
• Cable length: Max. 1000 m (point to
point). 500 m if used in patch-panel
topology
Field interface
CAN interface:
• 2 x CANopen/DeviceNet @ 5 pole
cage clamp terminals. 2.5 mm² cable
• Bit rate: Max. 1 Mb/s. (DeviceNet not
defi ned above 500 kb/s)