DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

CTI 2500 Series® Programmable Controllers

From:CTI | Author:LIAO | Time :2025-08-15 | 637 Browse: | 🔊 Click to read aloud ❚❚ | Share:

FEATURES

• Replaces all Simatic®

545 and 555 models

• Built-in Ethernet and USB ports for 

programming

• Built-in SD Flash card for firmware update 

from flash

• Built-in Profibus and RS485 Remote I/O on 

C200, C300, and C400 models

• Up to 3Mbytes memory, 8192 I/O points, 

512 PID loops & 512 alarms, depending on 

model

• Programmable using Workshop

• Integrity® Real Time Operating System for 

high-reliability and security

SPECIFICATIONS

Ports:

Ethernet, 100Mbit, RJ45

RS232C: DB9 male

Profibus: 12Mbit, DB9 female

Remote I/O: DB9 male

SD Flash card: up to 32G bytes (with Firmware 

V6.18 and higher)

Expansion port: future use

User Memory:

2500-C100: 128K

2500-C200: 256K

2500-C300: 512K

2500-C400: 3072K

Loops / Alarms:

2500-C100: 16 / 32

2500-C200: 64/ 128

2500-C300: 512 / 512

2500-C400: 512 / 512

Status Display: 3-Digit LED display for system

status, error reporting and IP address

Backplane Power: 7 Watts (maximum)

Operating Temperature: 0

o to 60oC

Storage Temperature: -40o

to 85oC

Relative Humidity: 5% to 95%

Agency Approvals: CE, UL UL-C, 

Class 1 Div 2

Shipping Weight: 1.5 lb. (0.68 Kg)

DESCRIPTION

The 2500 Series® Controllers bring exciting new 

features and a new level of process 

performance to Simatic®

505® Control Systems. 

The C100 and C200 models easily handle 

medium to large discrete control applications, as 

well as basic process applications. The C300 

and C400 models are equipped to handle large 

process applications with many PID loops and 

alarms and special mathematical functions. The 

2500 Series® Controllers are designed to 

seamlessly replace all Simatic®

545 and 555 

controllers while providing much higher 

performance at lower cost. The controllers are 

supported by a complete range of digital, 

analog, and specialized I/O modules, power 

supplies, and I/O bases, all available from CTI.

IMPORTANT NOTE: This product includes a lithium battery for backing up the user program, retentive variables, and 

system diagnostics. For safety in transportation, the battery is installed but disabled. Prior to putting this product into 

service, you MUST move dipswitch SW1 to the CLOSED position to enable the battery.

COMPATIBILITY OVERVIEW

The CTI 2500 Series® Processor is designed to be compatible with customer applications that use the Simatic®

545 and 

555 controllers. While the CTI 2500 matches or exceeds the capabilities of these processors in most aspects, there are a 

few areas in which the CTI 2500 operates differently.

Relay Ladder Logic

The RLL used in the controller provides equivalent instructions for all Simatic®

555 instructions except the XSUB 

instruction. External subroutines are not supported. If you download a program containing the XSUB instruction, it will be 

ignored. In many cases XSUB is used for communications with Siemens® Profibus HMI panels. For these installations 

we have a CTI program free on our website which replaces the XSUB. For XSUB uses other than Siemens® HMI panels, 

CTI and our partners can develop XSUB replacement software using SF programming. Please contact us.

Special Function Programs

The controller compiles all SF programs and subroutines. They are compiled in the following situations:

• When a user program is downloaded to the PLC, if the SF Program or subroutine is enabled,

• When the SF program or subroutine is enabled, if the SF program has been modified,

• During a Power Up start (following the application of power).

Programs that contain errors will not be enabled. During a program download, Workshop will display a message 

indicating the error. Once you acknowledge the message, the download will continue, leaving the program disabled. You 

must correct the programming error before the program or subroutine can be enabled. User Programs originally written 

for the Simatic®

505 PLC may contain undetected errors, if the programs were not originally compiled. This can occur 

because the SF interpreter never attempts to execute the instruction due to the branching logic. A common problem is 

that additional ENDIF statements are included or the correct number of ENDIF statements is not present.

Unlike the Simatic®

555, there are no restrictions regarding the instructions that can be used in a compiled program.

User Configuration

The following differences in the user configuration should be noted:

1. Allocation of CS memory is not supported. The CTI 2500 controller uses high speed DRAM to store and execute 

compiled SF programs and subroutines. Consequently, CS memory is not required.

2. User allocation of User Subroutine memory is not supported. The CTI 2500 controller does not support user 

subroutines (XSUB). See XSUB description above.

3. A time slice for Report by Exception (RBE) is not supported. Some alternative solutions exist. Please consult us with 

your exact configuration.

4. A new time slice, Network Communications, has been added to support the local Ethernet port.

I/O Support

The following are not presently supported. This is subject to change.

• Interrupt I/O

Support of Special Function Modules

  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-113 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-113 Protective Measurement Card
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK PICMG Single Board Computers NuPRO-900A
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cableles
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay