DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

BentlyBlocking and Test System Instruction Manual

From:Bently | Author:LIAO | Time :2025-08-04 | 371 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Introduction The GE Multilin 515 Blocking and Test Module has the following features:

• 14 Pole switchbank 

• CT inputs short when current switches are opened 

• Current injection for each phase • Ground terminal 

• Ability to visually isolate (open) trip relay output circuits 

• Cover provided • Suitable for utility and industrial use 

• 515 test plugs available

Description

The 515 Blocking and Test Module provides an effective means of trip blocking, relay isolation and testing of GE Multilin relays. By opening the switches and inserting test plugs, phase and residual currents from the primary CTs can be monitored. Currents can be injected into the relay from a secondary injection test set during commissioning. Prior to testing, the trip and auxiliary circuits must first be opened to prevent nuisance tripping; CTs can then be shorted. Conversely, when the test is complete and the relay put back into operation, the CT switches should be closed first to ensure normal operation of the relay, prior to closing the trip and auxiliary circuits

Installation

Shorting switches are provided for connection of 3 phase CTs (current transformers) and a separate core balance ground fault CT or 3 phase CTs connected for residual ground fault sensing. When each CT switch is opened, the CT is shorted. It is essential that the CT is connected to the shorted side of the switch as shown in the following figure, otherwise dangerously high voltages would be present from the open circuited CTs. When the switches are open, test plugs can be inserted to either inject signals into the relay wired to the switches or monitor signals such as CT current from the switchgear

The 515 Blocking and Test Module consists of a metal chassis attached to the 515 test switches that slides into the panel. A single cutout in the panel, as per the dimensions shown in Figure 3, is required to mount the 515 test switches.




Slide the metal chassis attached to the 515 test switches into the cutout from the front of the panel. While firmly applying pressure from the front of the 515 module to ensure the chassis fits snugly, bend out the retaining tabs as shown in Figure 3. Usually the retaining tabs will be sufficient to hold the 515 module securely in place. If additional fastening is desired bend out the clamping screw tabs at both ends of the chassis at right angles. Insert the #8 screws provided in the accessory pouch into the tapped holes with the vibration proof nut between the tab and the panel. Tighten each screw until the end of the screw butts firmly against the front panel. Ensure the nut


is installed tightly against the bent tab. Nylon inserts in these nuts prevent them from vibrating loose. The 515 test switch module should now be securely mounted to the panel with no movement ready for rear terminal wiring. When completed, place the front cover over the mounted 515 test module and turn the fasteners at both ends ¼ turn to lock it in place, as shown in Figure 3. As a safety precaution, a ground screw located on the bottom-right of the rear side of the module is available to be connected to panel chassis ground.• 1 package containing at least 28 terminal nuts 

• 14 white tags for identification of each of the switches

The 515 provides a means of trip blocking, relay isolation, and testing of GE Multilin relays. The 515 accomplishes this with a total of 14 switches. There are 6 single pole throw switches for use with the output relays, and 4 groups of 2 switches each for use with the current transformers as illustrated in Figure 1: Typical Wiring. Isolation or opening of the relay’s output circuits is accomplished with the six switches at terminals 1 through 6 and 15 through 20. These switches can be used to simply open the protection relay's output contacts and thus provide a means of blocking trips. The 4 remaining groups of 2 switches at terminals 7 through 14 and 21 through 28 are used for shorting of the CT inputs, injection of test current, and measuring of CT current. The four groups correspond to Phase 1 Current, Phase 2 Current, Phase 3 Current, and Ground Current. Each group is made up of two switches. The first switch for the Phase 1 group is at terminal 7 and 21 and is configured as shown on the right: Note that terminals 7 and 21 are shorted together regardless of whether the switch is open or closed. The second switch for the Phase 1 group is at terminals 8 and 22. It is configured as shown on the right: Note that this switch operates as make before break. When this switch is closed terminals 8 and 22 are shorted together. When this switch is open, terminals 8 and 22 open and 22 shorts with 7 and 21. This in turn shorts the Phase 1 CT. It is essential that the CT is connected to the shorted side of the switch as shown on the right. Otherwise, dangerously high voltages would be present at the open circuited current transformer. Also note that currents can be injected into the protection relay from a secondary injection test set. With the switch between terminals 7 and 21 open and the switch between terminals 8 and 22 closed as shown below, a 515 test plug can be inserted between terminals 7 and 21 to monitor the CT current. See the diagrams below for details. Note that the 515 test plug is made up of two conductors separated by an insulator.

  • AMAT 0100-00046 AC Current Sense PWB
  • AMAT A0414720 Precision Advanced System Controller
  • AMAT 0010-00017 Precision Semiconductor Process Interface
  • AMAT 01-82889-00 High-Performance Semiconductor Component
  • ABB Sample Gas Cooler SCC-C 23070-0-10232110
  • IBA ibaRackline-PCHD Efficient process analysis with ibaHD-Server
  • IBA ibaRackline-PC CAM Frame-accurate video information with ibaCapture
  • IBA ibaRackline-PC Highly available and reliable
  • IBA Optical Signal Multiplier ibaBM-FOX-i-3o-D
  • IBA Optical Data Distribution System ibaBM-DIS-i-8o
  • IBA Optical Data Concentrator ibaBM-COL-8i-o
  • IBA ibaNet750-BM-D Acquisition via FO
  • IBA ibaW-750 Acquisition via Ethernet
  • IBA ibaPADU-8AI-I Compact Measurement Modules
  • IBA ibaPADU-D-8AI-I Compact Measurement Modules
  • IBA ibaPADU-8AI-U Compact Measurement Modules
  • IBA ibaPADU-D-8AI-U Compact Measurement Modules
  • IBA ibaPADU-4-AI-U Compact Measurement Modules
  • IBA ibaPADU-C-8AI Self-Supplied Data Logger
  • IBA ibaBM-ENetIP Bus monitor for EtherNet/IP
  • IBA ibaBM-eCAT Bus monitor for EtherCAT
  • IBA ibaBM-DP Bus monitor for PROFIBUS
  • IBA ibaBM-PN: Bus monitor for PROFINET IO
  • IBA ibaMS3xAI-1A Precision AC Current Measurement Module
  • IBA ibaDAQ Intelligent Central Unit
  • IBA ibaPQU-S Power Quality Monitoring System
  • IBA ibaCMU-S Condition Monitoring Unit (CMU)
  • IBA ibaPADU-S-IT-2x16 Modular data acquisition and control system
  • IBA ibaPADU-S-CM Modular data acquisition system
  • IBA ibaM-4AI-IEPE Input module
  • IBA ibaM-4AI-UI Input module
  • IBA ibaM-4AI-150V-AC Input module
  • IBA ibaM-4AI-600V-AC Input module
  • IBA ibaLink-SM-256V: High-Density PLC Data Interface
  • IBA ibaLink-SM-64V High-Performance S5/S7 Interface
  • IBA ibaLink-SM-128V-i-2o Synchronous Fiber Optic (ibaNet)
  • IBA ibaLink-SM-128V communication module
  • IBA ibaM-4AI-5A-150A-AC Input module
  • IBA ibaM-FO-2IO Interface module
  • IBA ibaM-COM Communication module
  • IBA ibaM-DAQ Intelligent Processor Module
  • B&R ECE161-0 MULTI digital input module
  • B&R ECCP70-01 MULTI CPU type B 42 KByte SRAM
  • B&R ECCP60-01 MULTI CPU type B 42 KByte SRAM
  • B&R DI426 digital input module
  • B&R 2DS100.60-1 electronic drum sequencer Absolut encoder
  • B&R 2CP100.60-1 CPU MODULE
  • B&R 2BM100.9 High-performance I/O module
  • AMAT 0190-14928 SCR Power Controller (PVD Reverse Zone)
  • AMAT 0500-01065 300mm Loadlock Interface Interlock Board
  • AMAT 2000-21123 Advanced Vacuum Seal Assembly
  • AMAT 0660-00090 High-Performance Industrial Power Filter
  • AMAT 0240-34077 Centura Endpoint Controller Kit
  • AMAT 0195-10215 High-Precision Pedestal Assembly
  • AMAT 0190-76050 VGA Video Controller VME Module
  • AMAT 0190-75084 High-Performance Communication & Logic Controller
  • AMAT 0190-60287 Precision VME/cPCI Interface Control Module
  • AMAT 0190-53752 DI Water I/O Controller PCB
  • AMAT 0190-37993 DeviceNet Scanner Pro (3U CompactPCI)
  • AMAT 0190-37833 MKS CDN500R-5 EPI 300mm Interface Module
  • AMAT 0190-37771 MKS CDN500R Interlock Control Module
  • AMAT 0190-37616 High-Precision Analog Input/Output Interface
  • AMAT 0190-36787B ISAC CP I/O Block 2 (Top) - Revision B
  • AMAT 0190-36787 ISAC CP I/O Block 2 (Top)
  • AMAT 0190-36511 DIP294 DeviceNet I/O Control Block
  • AMAT 0190-35764 & 0190-35765: Precision Control Interface Duo
  • AMAT 0190-35763 High-Performance Integrated Power Module
  • Applied Materials (AMAT) 0190-34512 4-Channel DeviceNet Scanner Interface
  • Applied Materials (AMAT) 0190-34282 High-Stability Process Control Module
  • Applied Materials (AMAT) 0190-27707 High-Precision DeviceNet I/O Controller
  • Applied Materials (AMAT) 0190-27072 High-Performance Semiconductor Interface
  • AMAT 0190-24007 CPCI-3720CF Single Board Computer
  • AMAT 0190-23905 Spellman ESC High Voltage Power Supply
  • AMAT 0190-22967 High-Density Analog I/O Control Board
  • AMAT 0190-22543 High-Precision Analog Input/Output Module
  • AMAT 0190-17964 Etch DPS Interlock Module
  • AMAT 0190-17894 Interlock Module Conductor HART
  • AMAT 0190-17081 2U CompactPCI System Host Processor
  • AMAT 0190-16926 and 0190-16928 Based on Compact PCI
  • AMAT 0190-15915 Intelligent I/O Control Module
  • AMAT 0190-15840 4-Port UPA DeviceNet Interface Module
  • AMAT 0190-15384 Advanced Digital Signal Interface Module
  • AMAT 0190-14027 Wafer Flat Finder PCB
  • AMAT 0190-12695 SBS CL7 3U CompactPCI Single Board Computer
  • AMAT 0190-11817 CP3-SER16-TTL 16-Port Serial Interface Card
  • AMAT 0190-11524 CDN500-25 Interlock Module
  • AMAT 0190-07450 CompactPCI 48-Channel Digital I/O Interface Board
  • AMAT 0190-05990-001 Maglev Rotation System Controller (300mm)
  • AMAT 0190-05647 LK3710 Serial Module Transition Card
  • AMAT 0190-04457 High-Performance Integrated Circuit Control Module
  • Applied Materials (AMAT) 0190-04098 | 5.X Factory Interface I/O Distribution Board
  • Applied Materials (AMAT) 0190-03705 | MF Producer SE/E Interlock Module
  • Applied Materials (AMAT) 0190-02748 | Flex Scanner Transition Module
  • Applied Materials (AMAT) 0190-02362 | Mainframe Interlock 1 Relay Module
  • Applied Materials (AMAT) 0190-01227 | Intelligent Motor Control OMS Board
  • Applied Materials (AMAT) 0190-00318 | VME 486 Video Controller
  • Applied Materials (AMAT) 0130-14007 | Advanced RF Signal Assembly
  • Applied Materials (AMAT) 0130-14005 | RF Cable/Interface Assembly
  • Applied Materials (AMAT) 0130-01218 | High-Efficiency RF Interface Controller
  • Applied Materials (AMAT) 0110-77040 | Head Pneumatic Controller
  • Applied Materials (AMAT) 0110-00077 | Precision Control Module
  • AMAT 0101-57015 high-performance Next-Generation Deflection Amplifier Board
  • AMAT 0100-77040 critical Head Pneumatic Controller Board
  • AMAT 0100-76291 Data Buffer / Memory Expansion Interface
  • AMAT 0100-76290 Advanced I/O Interface Board
  • AMAT 0100-76269 Control Board / Interface Module
  • AMAT 0100-71462-01 high-performance Process Controller PCB
  • AMAT 0100-71171 Chamber Interlock Control PCB
  • AMAT 0100-71154 Semiconductor Circuit Board / Electronic Group Card
  • AMAT 0100-70034 PCB Assembly (PCBA) for Endpoint VGA I/O Interconnect.
  • AMAT 0100-38032 ESC (Electrostatic Chuck) Controller PCB
  • AMAT 0100-36035 DPS Source Match / Seriplex I/O Distribution PCB
  • AMAT 0100-35231 Seriplex I/O Distribution Module
  • AMAT 0100-35217 TC Amp Interlock PCB Module
  • AMAT 0100-35065 High-Precision Serial Isolator PCB
  • AMAT 0100-35054 Advanced Chamber Interface Module
  • AMAT 0100-20453 DeviceNet Digital I/O Interface Board
  • AMAT 0100-20100 High-Performance Semiconductor Component
  • AMAT 0100-20068 Precision CCD Image Control Board
  • AMAT 0100-20064 Advanced Semiconductor Control Module
  • Applied Materials (AMAT) 0100-20018 Advanced Communication Interface Module
  • Applied Materials (AMAT) 0100-20016 High-Performance Interface and Control Module
  • Applied Materials (AMAT) 0100-20003 Digital I/O (DI/DO) Interface Board
  • Applied Materials (AMAT) 0100-20001 System Electronics Interface (SEI) / PCB Assembly
  • Applied Materials (AMAT) 0100-11030 Chamber Hardware / Gas Distribution Component
  • Applied Materials (AMAT) 0100-11022 Semiconductor Board Card
  • Applied Materials (AMAT) 0100-11018 Advanced Interface Control Module
  • Applied Materials (AMAT) 0100-11001 Precision Analog Output Board