DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module

From:Foxboro | Author:yang | Time :2025-12-09 | 433 Browse: | 🔊 Click to read aloud ❚❚ | Share:

FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module

Overview

Single input/single output control schemes with high availability requirements can take

advantage of the FBM208 arranged as a redundant pair. A readback feature is

provided that detects failures of the output channel. In a repair situation, when a single

module is replaced, the inputs and outputs are maintained by the redundant module.

HART

signals are electrically compatible with the 4-20 mA signals, permitting the

plant to upgrade field devices without the need to change the control system. The

FBM208b provides the same functionality and is used to upgrade from the older

FBM05.

Aredundant pair of the modules combine to provide redundancy at the Fieldbus

Module (FBM) level, with field I/O wired to one common termination assembly (TA)

(see Figure 1. page 4). Each module independently attempts to hold the output(s) at

its specified output value(s), and each independently reports its observed value of the

inputs.

Aredundant analog iput and redundant analog output block in the Foxboro

DCS

Control Software validates each input and output in conjunction with information to/

from the module.

The FBM208is electrically compatible with standard HARTsignals.

• Four0to20mADCanaloginputchannels

• Four0to20mADCanalogoutputchannels with readback

• ComparesFBM’soutput value with the current readback value. If the readback

value differs from the desired output by more than ± 2%, the FBM marks its

output channel BAD.

• Monitors FBM’s internal channel current loop power and marks the channel BAD

if power is less than 16 VDC

• Marking achannel Bad causes the corresponding channel in the redundant

module to continue to drive the outputs

• Redundantmodules increase reliability

• Termination Assemblies (TAs) for locally or remotely connecting field wiring to the

FBM208

The FBMcomparesits output value with the current readback value. If the readback

value differs from the desired output by more than ±2%, the FBM marks its output

channel BAD. In addition, if the output value is greater than the desired output by

more than +2%, the power to that channel is shut off to help prevent the bad channel

from interfering with the control of that channel by the redundant partner FBM. The

power to a detected failed channel remains off until the FBM is replaced or rebooted

by the user.

Whenthe FBM’soutput channel is marked BAD, the CP presents that information to

the Foxboro DCS for display as a System Management alarm message and as a

control block alarm.

Redundant Analog Inputs

Each input channel accepts an analog sensor input such as a 4 to 20 mA transmitter

or a self-powered 4 to 20 mA source.

Transmitter power from each module is diode OR’d together in the redundant adapter

to help assure redundant power.

Aredundant analog input function block, AINR, is used for each redundant pair of

inputs. The AINR block handles input reads and initialization logic for the redundant

channels. On each execution cycle of the AINR block, identical reads are sent to both

modules, fully exercising the fieldbus and the logic circuitry of each module.

Input channel options include a configurable choice of integration time on a per

module basis. Input channel availability is enhanced by redundantly powering the

input current loop from per channel power supplies in each module of the pair.

Redundant Analog Outputs

Each output channel drives an external load and produces a 0 to 20 mA output.

Aredundant analog output block, AOUTR, is used for each redundant pair of outputs.

The AOUTRblock handles output writes and initialization logic for the redundant

channels. On each execution cycle of the AOUTR block, identical output writes are

sent to both modules, fully exercising the fieldbus and the logic circuitry of each

module. When a failure is detected in one of the modules, its output is driven to 0 mA

and the corresponding channel in the good module automatically continues supplying

the proper current to the output current loop.

Configurable options in the modules for output failsafe and fallback options are always

set to their default values (0 mA). This removes one of the pair of redundant output

channels from service for detectable problems such as a module not properly

receiving output writes or not passing diagnostic tests on FBM microprocessor writes

to output registers. Using the default failsafe/fallback options of 0 mA output also

minimizes the possibility of a “fail high” result.

High Accuracy

High Reliability

For high accuracy, the module incorporates sigma-delta converters for each channel.

This provides new analog input readings every 25 ms and a configurable integration

period to remove any process noise and power line frequencies. Each time period, the

FBMconverts each analog input to a digital value, averages these values over the

time period and provides the averaged value to the controller.

The redundancy of the module pair, coupled with the high coverage of detected faults,

provides a very high subsystem availability time.

The microprocessor of each module executes the analog I/O application program,

plus diagnostic routines that validate the health of the FBM.

Either module may be replaced without upsetting field input or output signals to the

  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module
  • SHINKAWA VW-202AL-8 Axial Displacement Sensor
  • Shinkawa VL-202A08L-1A42 Vibration Sensor Transducer Probe
  • Shinkawa VL-202A08L-1A42 Vibration Sensor Transducer Probe
  • Shinkawa FRP-209A & FRP-206 Wire Bonder Circuit Board Module
  • Shinkawa MGP-72 MGP72 P-26-50A P-26-50B Circuit Board Module
  • Shinkawa FRP-249 P-25-1A P-25-1B Circuit Board Module
  • Shinkawa FRP-320 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa FRP-282 P-24-35A P-24-35B Circuit Board Module
  • Shinkawa FRP-338 P-26-54A P-26-54B Circuit Board Module
  • GE IS200AEPBH1B IS200AEPBH1B‑REV‑AA Pitch-Charger Control PCB Board
  • GE IS200EDEXG1ADA EX2100 SCR Trigger Control Board
  • GE 151X1207CK01SA01 IS200EDEXG1A EX2100 SCR
  • GE 151X1233DD02SA02 IS200AEPBH1B - Variant for pitch control charger assembly
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01R | IS200AEPBH1B 10KW Converter
  • GE 151X1233DD01SA02 Pitch Battery Charger (109W6931P001)
  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)