DCS; Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

GEMark* V to Mark* VIe Migration

From:GE | Author:LIAO | Time :2025-08-19 | 273 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Overview

GE is proud to provide controls you can trust from experts you 

can trust. You can now add significant new performance 

enhancements to your Mark V control. GE offers a Mark VIe upgrade 

package with many new features and algorithms for new turbine 

functions, such as advanced dry low NOx

 systems and operational 

flexibility (OpFlex*) enhancements. The upgrade includes a 

complete modernization of operator stations and networks to 

current technology.

eTechnology Benefits

The Mark VIe provides performance, operability and reliability for 

today’s connected plant.

• Increased computational power – advanced technology 

Mark VIe processors provide access to sophisticated software 

enhancement modules to improve turbine performance, reliability, 

and operability. 

• Intuitive features – GE’s powerful ToolboxST* software, with 

modern drag-and-drop type editors, industry leading trender with 

video type forward-reverse-freeze capability, and code-compare 

tools.

• Increased operational productivity – user-friendly HMI 

graphics, alarm/event management, and trending leading to 

improved operator recognition and resolution of system faults.

• Maintenance efficiency improvements – reduced engineering 

time due to a single integrated software tool for configuring 

networks, processors, and I/O boards, along with editing 

application software, managing block libraries, and displaying 

system diagnostics.

• Latest GE software libraries – Leverages years of GE OEM 

experience to ensure safety-related software updates are 

delivered while also retaining the majority of the existing control 

system customization. 

• Improved reliability – TMR controller redundancy provides 2 

out of 3 voting to improve reliability and eliminate single-point 

communication failures within the control. 

• I/O expandability – flexible and modular architecture allows for 

future growth of capabilities and applications.

• Built with cyber security best practices – Achilles™ 

Communications Certification Level 1 Mark VIe Controllers 

feature hardened network switches and HMIs within a segmented 

network.

Hardware Features

The Mark V to VIe migration consists of a streamlined hardware 

configuration to provide the performance capabilities and reliability 

to meet the requirements of your operation.

• Reduced downtime – a migration can be done in as few as 9 days 

with 5 outage days using the existing cabinet footprint, with no 

impact to field wiring or turbine devices. Coordinated installation 

between the customer and GE reduces migration time and 

provides on-site education during installation.

• Ethernet backbone – provides expandability as well as 

protection against control system component obsolescence. 

In other words, obsolescence is now handled “componentby-component” rather than “system-by-system.” Modernized 

communication conforms to modern IEEE 802.3 standards.

• Lifecycle maintainability – the new Mark VIe boards and the 

existing Mark V components not replaced during the migration 

process assume the lifecycle and support of the Mark VIe control 

system.

Operator Interface

The HMI for the Mark VIe uses a Windows™ operating system. With 

this HMI, your existing operator and maintenance stations will have 

the latest HMI/SCADA Cimplicity* graphics system featuring easy 

screen navigation, alarm/event management and trending tools. In 

addition, Windows™ 7 HMIs use the latest versions of ControlST* 

and ToolBoxST which will augment your existing Modbus and TCP-IP 

GSM links to plant controls.

OpFlex Software Enhancement Modules

GE’s OpFlex software enhancement modules add significant new 

performance enhancements to your Mark VIe turbine control to 

improve reliability, provide system diagnostics, help to prevent 

trips, and improve operator productivity. There are four packages 

featuring 20 modules which complement the power of the Mark VIe 

control system.

Cyber Security

Upgrading to the Mark VIe control system allows you to take 

advantage of GE’s cyber security solutions, helping reduce your risk. 

Our cyber security solution provides defense-in-depth protection. 

The SecurityST* Mark VIe Solution and Commissioning Services is 

Achilles™ Practice Certified – Bronze, indicating the solution has 

undergone strict cyber security best practices demonstrating to 

customers that systems are developed and implemented securely. 

The Security ST appliance and Cyber Asset Protection Subscription 

are designed to support the plant operation’s compliance to cyber 

security standards and guidelines including NERC CIP, NEI 08-09 

and ISA99/IEC 62443. 

Controls LifeCare* Partnership

This comprehensive subscription helps to maintain the health 

of turbine and plant control, generator control and static starter 

systems. Subscribers benefit from GE expertise and a true 

partnership in the maintenance and servicing of control systems 

  • MOTOROLA TMCP700 W33378F High-Performance Industrial Computing Module
  • MOTOROLA VME Single Board Computer MVME188A
  • MOTOROLA MVME162PA-344 High-Performance Embedded VME Controller
  • MOTOROLA FAB 0340-1049 High-Efficiency Intelligent Embedded Module
  • MOTOROLA 30-W2960B01A High-Performance Industrial Interface Module
  • MOTOROLA MVME712M Transition Module.
  • MOTOROLA MVME5500 Series VME Single-Board
  • MOTOROLA MVME300 High-Reliability GPIB VMEbus Controller
  • MOTOROLA CPCI-6020TM High-Performance CompactPCI Transition Module
  • MOTOROLA MVME162-210 Embedded Controller
  • MOTOROLA MVME162-522A 01-W3960B/61C Embedded Controller
  • MOTOROLA MVME162-512A Embedded Controller
  • MOTOROLA MVME162-512 Embedded Controller
  • MOTOROLA MVME162-220 Embedded Controller
  • MOTOROLA MVME162-13 Embedded Controller
  • MOTOROLA MVME162-10 Embedded Controller
  • MOTOROLA MVME162-012 Embedded Controller
  • MOTOROLA MCP750 CompactPCI Host Slot Processor
  • Phoenix 2320267 QUINT-UPS/ 24DC/ 24DC/10/3.4AH - Uninterruptible power supply
  • Phoenix QUINT4-PS/3AC/24DC/40 - Power supply 2904623
  • Phoenix 2904622 QUINT4-PS/3AC/24DC/20 - Power supply
  • Phoenix 2905012 QUINT-PS/96-110DC/24DC/10/CO - DC/DC converter, protective coating
  • Phoenix 2905011 QUINT-PS/60-72DC/24DC/10/CO - DC/DC converter, protective coating
  • Phoenix 2904600 QUINT4-PS/1AC/24DC/5 - Power supply
  • Phoenix 2904603 QUINT4-PS/1AC/24DC/40 - Power supply
  • Phoenix 2904601 QUINT4-PS/1AC/24DC/10 - Power supply
  • Phoenix 2904602 QUINT4-PS/1AC/24DC/20 - Power supply
  • Phoenix QUINT-PS/60-72DC/24DC/10 - DC/DC converter 2905009
  • Phoenix QUINT-PS/96-110DC/24DC/10 - DC/DC converter 2905010
  • Phoenix QUINT-PS/3AC/24DC/20/CO - Power supply, with protective coating 2320924
  • Phoenix QUINT-PS/1AC/12DC/20 - Power supply 2866721
  • Phoenix 2320908 QUINT-PS/1AC/24DC/ 5/CO - Power supply, with protective coating
  • Phoenix 2866213 QUINT-BUFFER/24DC/20 - Buffer module
  • Phoenix 2866585 QUINT-DIODE/48DC/40 - Redundancy module, with protective coating
  • Phoenix 2320393 QUINT-BUFFER/24DC/24DC/40 - Buffer module
  • Phoenix 2320157 QUINT-DIODE/12-24DC/2X20/1X40 - Redundancy module
  • Phoenix 2907720 QUINT4-DIODE/48DC/2X20/1X40 - Redundancy module
  • Phoenix 2907719 QUINT4-DIODE/12-24DC/2X20/1X40 - Redundancy module
  • Metso A419471 High-Performance Analog Output Module
  • Applied Materials (AMAT) 0190-19092: High-Performance RF Match Controller Board
  • ABB UFC789AE101 3BHE014023R0101 High-Performance AC 800PEC Control Unit
  • GE MIFIIPA55E20HI00 Multilin MIF II Digital Feeder Protection Relay
  • GE DS3815PAHB1A1A Speedtronic Mark IV Processor & Interface Board
  • GE DS3800NB1A Speedtronic Mark IV Power Supply / Regulator Board
  • GE DS3800HIOC Speedtronic Mark IV High-Level Input/Output Board
  • GE DS3800NHVG Speedtronic Mark IV High-Voltage Gate Driver Board
  • ABB 1TGE120011R1010 MC M117 KIT 24VDC CMMB+PTC
  • Woodward 5448-897 Current Differential Protection Relay
  • GE IS220PAOCH1BE Mark VIe Analog I/O Module
  • GE IS220PDOAH1B Mark VIe Discrete Output (PDOA) I/O Pack
  • ABB Feeder Protection and Control REF620E_1G NBFNAAAAAABC6BBN11G
  • ABB MT-91-ARCFPA High-Precision Tension Control Interface Module
  • HIMA PS1000/230010 982200080 high-performance power supply module
  • HIMA H7202 Distribution Fuse Board / Infeed Board
  • HIMA F60DIO24/1601 Safety-Related Controller
  • HIMA F60DO801 Safety-Related Controller
  • HIMA H7201 Line fuse board
  • HIMA HIMatrix ELOP II 892042336 Version V5.6 Build 1501.9810 IV1
  • HIMA HIMatrix SILworX 504110 895400001
  • HIMA HIMatrix SILworX 504111 895210001
  • HIMA OPC DA Server 892042400 Version 3.56.4
  • HIMA OPC Alarm & Event Server (892042420) Version 4.1.3
  • HIMA OPC Alarm & Event Server (892042420) Version 4.0.5
  • Phoenix QUINT-DIODE/12-24DC/2x20/1x40 2320157 Redundancy module
  • Phoenix QUINT-PS/1AC/24DC/40 2866789 Power supply
  • Moore SIY/PRG/4-20MA/10-42DC SIY PC Programmable Signal Isolator and Converter
  • Motorola 01-W3394F-03F Communication Interface Module
  • Motorola AP-4 256 MByte 01-W3839F-07A Communication Module
  • MOTOROLA MVME2432 01-W3394F-03C VME Processor Module
  • MOTOROLA PCE I 01-W3839F-07A VME Processor Module
  • Motorola HPR431 / SYS431 / SYS443 / MFT543 Component Assembly
  • Motorola AP-4 01-W3394F-03G Communication Interface Module
  • Emerson 01-W3878F-02D DeltaV M-Series I/O Module
  • ICS Triplex Trusted T8232 Power Pack Module
  • ALFA LAVAL AAL7000 OXYGEN ANALYSER V0.1
  • Alstom MPM123 Measurement and Protection Module
  • Honeywell 5701 CONTROL SYSTEM
  • KONGSBERG MRU-E-JB1 Host machine
  • Woodward easYgen-3200-1/P1 8440-2049
  • Woodward easYPROTEC-1410-7 8441-1161 8441-1160
  • Woodward MFR300-71M/K45 8444-1111 8444-1112
  • Woodward MFR300-75M 8444-1107 8444-1108 8444-1109
  • Woodward MFR300-71M/K42 8444-1104
  • Woodward MFR300 75M/SU03, Transducer 8444-1093 8444-1094 8444-1095
  • Woodward MFR300-71M 8444-1091 8444-1092
  • Woodward MFR300-15M 8444-1090 8444-1089
  • Woodward MFR300-11M 8444-1071 8440-1089
  • Woodward MFR500-6M/WK0400 + DPC USB 8444-1070
  • Woodward MFR300-15M 8444-1064
  • Woodward SPM-D2-1040B/NYB 8440-2189
  • Woodward SPM-D2-1010B/NYB 8440-2177
  • Woodward SPM-D2-10B/PSY5-FU-D 8440-2170
  • Woodward SPM-D2-1040B/XN analog speed/voltage bias 8440-2190
  • Woodward MFR300-71M 8444-1063
  • SPM-D2-1010B/X analog speed/voltage bias 8440-2168
  • Woodward SPM-D2-1040B/X analog speed/voltage bias 8440-2171
  • Woodward SPM-D2-1010B/N wide range power supply 8440-2174
  • Woodward SPM-D2-1040B/N wide range power supply 8440-2175
  • Woodward SPM-D2-1010B /110VAC sensing 8440-2166
  • Woodward SPM-D2-1040B /400VAC sensing 8440-2164
  • Woodward DTSC-200A 8440-2297
  • Woodward DTSC-200-55B/K38 8440-2155
  • Woodward DTSC-200-51B 8440-1867 8440-1868
  • Woodward 8445-1049 8445-1048 Converter, 1x FO to CAN
  • Woodward easYlite-200 8446-1007 LED Lamp Expansion Module
  • Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306
  • Woodward IKD-IN-16 16 DI Expansion Card 8440-2307
  • Woodward IKD1M 8 DI/8 DO Expansion Card 8440-2116
  • Woodward easYview-07-30 8446-1071
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easY-I-3400XT-P1 8440-2293
  • Woodward easY-I-3500XT-P1 8440-2292
  • Woodward MSLC-2XT 8440-2298 Master Synchronizer and Load Control
  • Woodward DSLC-2XT 8440-2299 Digital Synchronizer and Load Control
  • Woodward: GC-3400XT-P1 8440-2267 Group Controller
  • Woodward: LS-612XT-P2 8440-2317
  • Woodward: CONTROL-LS-612XT-P1,8440-2222 Cabinet back mounting
  • Woodward: LS-522-1/P1 8440-2179
  • Woodward: LS-522-5/P1 8440-2151
  • Woodward: LS-512-1/P1 8440-2181
  • Woodward: LS-512-5/P1 8440-2153
  • Woodward: LS-521-1/P1 8440-2178
  • Woodward: CONTROL-LS-521-5/P1 8440-2150
  • Woodward: LS-511-1/P1 8440-2180 Circuit Breaker Control & Protection
  • Woodward: CONTROL-LS-511-5/P1 8440-2152 Circuit Breaker Control & Protection
  • Woodward easYgen-3500XT-P2-LT-RENTAL 8440-2291 Genset Control for
  • Woodward eeasYgen-3500XT-P2-RENTAL 8440-2290
  • Woodward easYgen-3200XT-RENTAL 8440-2285