DEIF MVR-F255 Directional Feeder Protection
MVR-F255
Directional Feeder Protection
The MVR-F255 feeder protection relay offers directional feeder protection for applications which require a large I/O capacity and most comprehensive protection functionality including advanced communication.
The MVR-F255 feeder protection relay was developed for application which require a most comprehensive functionality for feeder protection and a large capcity of I/Os. The device supports IEC 61850 communication. With 11 available extension slots the device is best equipped for most complex feeder applications.
- 5x Current input (configurable 0.2…10A)
- 4x Voltage input (1.00…480.00V (RMS)
- 3x Digital input
- 5x Output relay (4NO, 1CO)
- 1x IRF output (1CO)
- 2x Remote com port (1 x RJ45 Ethernet and 1 x RS-485)
- IEC 61850 Ed1 & Ed2. Modbus TCP/RTU, IEC 60870-5-104/103/101. DNP 3.0. SPA protocols
- DT, IEC or ANSI time/overcurrent curves with settable release delays
- 11 extension slots for additional hardware options
- Event recorder (up to 15 000 events)
- Disturbance recorder (up to 100 disturbance records)
Available Extension Cards:
- 8x digital inputs (programmable threshold voltage)
- 5x output relays
- Arc-Flash Protection - 4x sensor channels, 2x HSO1. 1x BI *)
- 8x RTD input
- 2x RJ45 100Mb Ethernet & IRIG-B *)
- 2x ST 100Mb Ethernet & IRIG-B *)
- 4x mA outputs - 1 x mA input
- 2x LC 100MB Ethernet (HSR, PRP redundant protocols)
- 2x RJ45 100MB Ethernet (HSR, PRP redundant protocols) *)
- RS-232 - Serial Fiber
Features
Protection Functions:
Three-phase over-current protection INST, DT or IDMT (ANSI 50/51)
Directional (sensitive) residual over-current protection stages DT or IDMT (ANSI 67N)
Directional three-phase over-current protection stages DT or IDMT (ANSI 67)
(Sensitive) Earth fault protection stages INST, DT or IDMT (ANSI 50N/51N(S))
Auto-reclose (ANSI 79)
Breaker failure protection (ANSI 50BF)
Cable-end differential protection (ANSI 87)
Cold-load pick-up block (ANSI 68)
Current transformer supervision (ANSI 60L)
Current unbalance/broken conductor protection stages INST, DT or IDMT (ANSI 46 /R/L)
Fault locator (ANSI 21FL)
Frequency protection stages (ANSI 81O/U)
Fuse failure (ANSI 60)
Harmonic over-current protection/inrush blocking stages INST, DT or IDMT (ANSI 50H/51H/68)
Intermittent earth fault (ANSI 67NT)
Overvoltage protection INST, DT or IDMT (ANSI 59)
Positive/negative sequence under-/over-voltage protection INST, DT or IDMT (ANSI 27P/47/59P)
Programmable stage (ANSI 99)
Rate of Change of Frequency ROCOF (ANSI 81R)
Residual voltage protection INST, DT or IDMT (ANSI 59N)
Restricted low-impedance earth fault protection (ANSI 87N)
Reverse-/under-/over-power protection INDT, DT or IDMT (ANSI 32)
Switch onto fault logic (SOTF)
Synchrocheck (ANSI 25)
Thermal overload protection (line) (ANSI 49L)
Under-voltage protection INST, DT or IDMT (ANSI 27)
Vector jump/surge (ANSI 78)
Voltage memory
| EMERSON | PR6423 009-041+CON 041/913-030 |
| Honeywell | HCIX15-TE-FA-NC |
| KEBA | D3-DU 360/A-2100-20 |
| SARTORIUS | MDB-8E |
| ALSTOM | ALSPA CE 80-20 |
| ALSTOM | Test PLUG MMLB01 |
| Rolls-Royce | ACP-04S19-002 |
| ABB | REM545BG227AAAB |
| EPRO | PR9376/010-011+CON021 |
| Rolls-Royce - | ACP-04S12-001 20095201 |
| ABB | RET 670*2.0-A40X00 Order = 4202183240-130 Ordering no: 1MRK004816-CE |
| MOOG | 6+PE B97007 |
| YOKOGAWA | GC8000 |
| IFS | IFS DE7210M |
| EXPO | ETM-IS31-001 |
| ABB | AC10272001R0101 5SXE10-0181 |
| Kawasaki | C-B10-A100-21 |
| ABB | CTI 21-P 3BDH000741R1 |
| EPRO | PR9268/600-000 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|