A-BPOINT I/O EtherNet/IP Adapter Catalog Number 1734-AENTInstallation Instructions

From:A-B | Author:LIAO | Time :2025-08-13 | 959 Browse: | 🔊 Click to read aloud ❚❚ | Share:

mportant User Information

Because of the variety of uses for the products described in this 

publication, those responsible for the application and use of these 

products must satisfy themselves that all necessary steps have been 

taken to assure that each application and use meets all performance 

and safety requirements, including any applicable laws, regulations, 

codes and standards. In no event will Rockwell Automation be 

responsible or liable for indirect or consequential damage resulting 

from the use or application of these products.

Any illustrations, charts, sample programs, and layout examples 

shown in this publication are intended solely for purposes of 

example. Since there are many variables and requirements associated 

with any particular installation, Rockwell Automation does not 

assume responsibility or liability (to include intellectual property 

liability) for actual use based upon the examples shown in this 

publication.

Allen-Bradley publication SGI-1.1, Safety Guidelines for the 

Application, Installation and Maintenance of Solid-State Control 

(available from your local Rockwell Automation office), describes 

some important differences between solid-state equipment and 

electromechanical devices that should be taken into consideration 

when applying products such as those described in this publication.

Reproduction of the contents of this copyrighted publication, in 

whole or part, without written permission of Rockwell Automation, is 

prohibited.

Throughout this publication, notes may be used to make you aware 

of safety considerations. The following annotations and their 

accompanying statements help you to identify a potential hazard, 

avoid a potential hazard, and recognize the consequences of a 

potential hazard

Environment and Enclosure

This equipment is intended for use in a Pollution 

Degree 2 industrial environment, in overvoltage 

Category II applications (as defined in IEC 

publication 60664-1), at altitudes up to 2000 meters 

without derating.

This equipment is considered Group 1, Class A 

industrial equipment according to IEC/CISPR 

Publication 11. Without appropriate precautions, 

there may be potential difficulties ensuring 

electromagnetic compatibility in other environments 

due to conducted as well as radiated disturbance.

This equipment is supplied as "open type" 

equipment. It must be mounted within an enclosure 

that is suitably designed for those specific 

environmental conditions that will be present and 

appropriately designed to prevent personal injury 

resulting from accessibility to live parts. The interior 

of the enclosure must be accessible only by the use 

of a tool. Subsequent sections of this publication 

may contain additional information regarding 

specific enclosure type ratings that are required to 

comply with certain product safety certifications.

See NEMA Standards publication 250 and IEC 

publication 60529, as applicable, for explanations of 

the degrees of protection provided by different 

types of enclosure. Also, see the appropriate 

sections in this publication, as well as the 

Allen-Bradley publication 1770-4.1 ("Industrial 

Automation Wiring and Grounding Guidelines"), for 

additional installation requirements pertaining to 

this equipmen

Preventing Electrostatic Discharge

This equipment is sensitive to electrostatic 

discharge, which can cause internal damage and 

affect normal operation. Follow these guidelines 

when you handle this equipment:

• Touch a grounded object to discharge 

potential static.

• Wear an approved grounding wriststrap.

• Do not touch connectors or pins on 

component boards.

• Do not touch circuit components inside the 

equipment.

• If available, use a static-safe workstation.

• When not in use, store the equipment in 

appropriate static-safe packaging.

ATTENTION POINT I/O is grounded through the DIN rail to 

chassis ground. Use zinc-plated, yellow-chromated 

steel DIN rail to assure proper grounding. Using 

other DIN rail materials (e.g., aluminum, plastic, 

etc.) which can corrode, oxidize or are poor 

conductors, can result in improper or intermittent 

platform grounding.

WARNING When you connect or disconnect the Removable 

Terminal Block (RTB) with field side power 

applied, an electrical arc can occur. This could 

cause an explosion in hazardous location 

installations.

Be sure that power is removed or the area is 

nonhazardous before proceeding

Before You Begin 

 To effectively use your adapter, note the following considerations. 

Determine Compatibility

If using the 1734-AENT adapter with a 1756-ENBT module or 

1788-ENBT module, use the following required firmware versions for 

these bridge modules:

• 1756-ENBT firmware version 2.3 or greater

• 1788-ENBT firmware version 1.33 or greater

If you use the BootP Utility to assign IP addresses to the adapter, use 

  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-113 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-113 Protective Measurement Card
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK PICMG Single Board Computers NuPRO-900A
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cableles
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control