DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

EMERSONSuspension Concentrate (SC) for Mite Management on Commercial Ornamental Plants in Greenhouses, Saran and Shade Houses, Outdoor Containers, and Field Grown Nursery Stock

From:EMERSON | Author:LIAO | Time :2025-08-18 | 659 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Suspension Concentrate (SC) for Mite Management on Commercial Ornamental Plants in Greenhouses, Saran and Shade Houses, Outdoor Containers, and Field Grown Nursery Stock

• Excellent for IPM programs for mite control.

• New class of chemistry ideal for use with other miticides to prevent resistance.

• Control of many species of mites.

• Long residual control up to 45 days.

• Can be tank mixed with other miticides or insecticides to broaden the spectrum of

pests controlled.

ACTIVE INGREDIENT: Percent By Weight

Clofentezine (3,6-bis (2-chlorophenyl) -

1,2,4,5-tetrazine) .............................................. 42%

OTHER INGREDIENTS ....................................... 58%

TOTAL 100%

Contains 1 pound of active ingredient per quart (32 fl. oz.).

KEEP OUT OF REACH OF CHILDREN

CAUTION

FIRST AID

IF ON SKIN OR CLOTHING: Take off contaminated clothing. Rinse

skin immediately with plenty of water for 15-20 minutes. Call a

poison control center or doctor for treatment advice.

IF IN EYES: Hold eye open and rinse slowly and gently with water

for 15-20 minutes. Remove contact lenses, if present, after the

first 5 minutes, then continue rinsing the eye. Call a poison

control center or doctor for treatment advice.

PRECAUTIONARY STATEMENTS

HAZARDS TO HUMANS

AND DOMESTIC ANIMALS

CAUTION

Avoid contact with skin, eyes, or clothing. Wash thoroughly

with soap and water after handling. Remove contaminated

clothing and wash before reuse.

PERSONAL PROTECTIVE EQUIPMENT (PPE)

Some materials that are chemical-resistant to this product

are listed below. If you want more options, follow the

instructions for category C on an EPA chemical resistance

category selection chart.

Applicators and other handlers must wear:

• Long-sleeved shirt and long pants

• Chemical-resistant gloves, such as barrier laminate,

butyl rubber, nitrile rubber, neoprene rubber, poly-vinyl

chloride (PVC), or Viton.

• Shoes plus socks

Follow manufacturer’s instructions for cleaning/maintaining

PPE. If no such instructions for washables, use detergent

and hot water. Keep and wash PPE separately from other

laundry.

ENGINEERING CONTROLS STATEMENT

When handlers use closed systems, enclosed cabs, or aircraft

in a manner that meets the requirements listed in the Worker

Protection Standard (WPS) for agricultural pesticides [40 CFR

Part 170.240 (d) (4-6)], the handler PPE requirements may be

reduced or modified as specified in the WPS.

USER SAFETY RECOMMENDATIONS

Users should:

• Wash hands before eating, drinking, chewing gum, using

tobacco, or using the toilet.

ENVIRONMENTAL HAZARDS

For terrestrial uses, do not apply directly to water, or to areas

where surface water is present, or to intertidal areas below

the mean high water mark. Do not apply within 100 feet of

lakes, reservoirs, rivers, permanent streams, marshes, natural ponds, estuaries, and commercial fish farm ponds. Do not

apply when weather conditions favor drift from treated area.

Do not allow spray to drift off of crop, especially when

spraying outer rows. Always direct spray into the crop. Do

not contaminate water when disposing of equipment 

washwaters.

IMPORTANT — Read the entire Directions for Use and Disclaimer

of Warranties before using this product.

Distributed by:

Scotts-Sierra Crop Protection Company

14111 Scottslawn Road

Marysville, OH 43041

1-800-492-8255

EPA Reg. No. 432-946-58185

EPA Est. No. 264-DEU-007, Aventis-Wolfenbuttel, Germany

NET CONTENTS: 1 pint (473 ml)

©2000, The Scotts Company. World rights reserved.

Ovation™ SC is a registered trademark of Scotts-Sierra Crop Protection Company for

its brand of plant protection products.

Suspension Concentrate (SC)

for Mite Management on

Commercial Ornamental

Plants in Greenhouses,

Saran and Shade Houses,

Outdoor Containers, and

Field Grown Nursery Stock

O

STORAGE AND DISPOSAL

PROHIBITIONS: Do not contaminate water, food or feed

by storage or disposal.

STORAGE: Store in original container, tightly closed, in a

safe place.

PESTICIDE DISPOSAL: Wastes resulting from the use of

this product may be disposed of on site or at an approved

waste disposal facility.

CONTAINER DISPOSAL: Triple rinse (or equivalent).

Then offer for recycling or reconditioning, or puncture

and dispose of in a sanitary landfill, or by incineration,

or, if allowed by State and local authorities, by burning.

If burned, stay out of smoke.

DO NOT RE-USE EMPTY CONTAINER


DIRECTIONS FOR USE

It is a violation to Federal law to use this product in a manner

inconsistent with its labeling.

Do not apply this product in a way that will contact workers

or other persons, either directly or through drift. Only

protected handlers may be in the area during application.

For any requirements specific to your State or Tribe, consult

the agency responsible for pesticide regulation.

AGRICULTURAL USE REQUIREMENTS

Use this product only in accordance with its labeling and

with the Worker Protection Standard, 40 CFR Part 170.

This Standard contains requirements for the protection

of agricultural workers on farms, forests, nurseries, and 

greenhouses, and handlers of agricultural pesticides.

It contains requirements for training, decontamination,

notification, and emergency assistance. It also contains 

specific instructions and exceptions pertaining to the 

statements on this label about personal protective 

equipment (PPE) and restricted-entry interval.

The requirements in this box only apply to uses of this 

product that are covered by the Worker Protection Standard.

Do not enter or allow worker entry into treated areas during

the restricted entry interval (REI) of 12 hours.

PPE required for early entry to treated areas that is permitted

under the Worker Protection Standard and that involves 

contact with anything that has been treated, such as plants,

soil, or water, is:

• Coveralls

• Chemical-resistant gloves such as barrier laminate, butyl 

rubber, nitrile rubber, neoprene rubber, poly-vinyl chloride

(PVC), or Viton

• Shoes plus socks

GENERAL INFORMATION

Ovation SC Ovicide/Miticide is recommended for use on ornamental

plants, (including but not limited to, conifers and non-bearing trees and

vines, carnations, chrysanthemums, diffenbachia, geraniums, impatiens,

hydrangeas, potentillas, scheffleras, and roses) in greenhouses, saran and

shade houses, outdoor container, and field grown ornamental nursery

stock for management of plant-feeding mites.

Ovation SC is highly active on mite eggs and early mite stages. It has

shown activity and persistence up to 45 days after application. Proper

timing of application, based on the utilization of scouting, may delay or

eliminate the need for subsequent applications of other miticides.

MIXING INSTRUCTIONS

Add the appropriate amount of Ovation SC to a partially filled spray

tank under agitation. After adding Ovation SC, other tank mix

components (adjuvants, fungicides, insecticides), if required, may be

added along with sufficient water to bring to the proper volume.

Maintain agitation.

Adjuvant Addition:

Often addition of adjuvants (stickers, spreaders, spreader-stickers,

dormant oils, etc.) will aid in the performance of plant protection 

products under certain conditions. Generally, an adjuvant is not

required with Ovation SC where adequate spray coverage is achieved.

Should inadequate spreading of the Ovation SC spray occur, the 

addition of a spreader or spreader-sticker may be considered. If 

addition is warranted, trial applications must be followed, using the

instructions in the section below “Notice to Users” as phytotoxicity 

can result from such additions.

pH Stability/Compatibility with Other Products:

Ovation SC is extremely stable over a wide range of pH. It has proven

to be physically and chemically stable in tank mixes with a wide range

of other plant protection products. If tank mixing is planned, evaluate

both the physical and chemical (phytotoxicity) compatibility on a

selected group of plants prior to full scale use. See “Notice to Users”

section below.

Notice to Users:

Ovation™ SC has demonstrated excellent plant safety, however,

all species and varieties of ornamental plant types have not been

tested. If a user wishes to make an application to an ornamental

plant type not listed on the label but found on a similar use site

and for a pest that is listed on the label, it is suggested that a trial

application be performed first.

For trial application, make 2 applications at a 7 day interval,

2 fl. oz. per 100 gal., to 25 or more test plants grown under 

conditions similar to those under which the plants will be grown

full scale. Wait 7 days after last application for final observation

for phytotoxicity.

Ovation™ SC is magenta in color and may leave a residue on

light colored flowers or foliage.

APPLICATION RECOMMENDATIONS

Ovation SC Ovicide/Miticide is recommended at a concentration 

of 2 fl. oz. per 100 gal. when used in high volume sprays using

hand-held equipment. For low and ultra-low volume applications,

apply 4-8 fl. oz. per acre, per application Applications irrespective

of delivery method should not exceed 8 fl. oz. per acre.

Spray application should be directed in a manner to cover all

plant surfaces, especially the undersides of leaves.

Do not apply this product through any type of irrigation system.

Frequency:

Ovation SC application is recommended only once per each crop

cycle in greenhouse and saran and shade house culture. For 

outdoor ornamentals, Ovation SC application is recommended

once per each crop cycle occurring within a year.

Mites Controlled:

Two-spotted spider mite European red mite

Pacific spider mite Yellow spider mite

McDaniel spider mite

Control is achieved through direct spray contact or by mite

contact with Ovation SC residue on the treated foliage.

Timing:

Ovation SC is most effective in mite management when applied

at the first sign of mite activity and egg laying. At that time, the

susceptible female mite, egg and first stage mite largely or totally

make up the population. If a high population of adult mites are

present at the time of application, Ovation SC should be tank

mixed with an adult miticide. Test any tank mix for physical compatibility and crop phytotoxicity before broad scale application.

RESISTANCE MANAGEMENT

Ovation SC is an excellent tool for growers to use in their mite

resistance management program. Proper application timing of

Ovation SC may delay or reduce the number of subsequent 

applications of other miticides, extending their effective life as

mite management products.

IPM / COMPATIBILITY WITH BENEFICIAL

MITES, PREDATORY INSECTS, ETC. 

Ovation SC has proven to have limited to no effect on beneficial

insects, particularly predatory mites. Ovation SC can be 

effectively and safely used in IPM programs employing 

beneficial insects.

MPORTANT NOTICE:

DISCLAIMER AND LIMITATION OF LIABILITY

This product has been researched to provide necessary data 

to support its use on ornamental plants. The user should always

follow the label directions and exercise judgment and caution

when using this product under their growing conditions. NO

WARRANTY OR REPRESENTATION IS MADE, EXPRESS OR IMPLIED,

CONCERNING THE RESULTS OBTAINED FROM THE USE OF THIS

PRODUCT. The exclusive remedy of the user or Buyer, and the

limit of liability of The Scotts Company or its affiliates, for any and

all losses, injuries or damages resulting from the use or handling

of this product shall be the purchase price paid by the user or

Buyer for the quantity of this product involved. The Buyer and all

users are deemed to have accepted the terms of this Notice,

which may be varied only by agreement in writing, signed by a

duly authorized representative of The Scotts Company


  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card
  • Adlink Centralized Motion Controllers PCI-8164
  • ADLINK PCI-7230/33/34 32-CH Isolated DIO PCI Cardsrd
  • ADLINK NUPRO-E320DV/NUPRO-E320 industrial control motherboard
  • Adlink PCI-8154 Advanced 4-axis Servo & Stepper Motion Controller
  • Adlink cPCI-3534/3538-S Series 4/8-port Asynchronous Serial Communications Modules
  • ADLINK Adlink Digital I/O PCI-7396
  • ADLINK 6U Rear Transition Modules cPCI-R6700 Series
  • ADLINK cPCI-6700B Industrial Control Board
  • ADLINK NuPRO-965/ NuPRO-965LV PICMG Single Board Computers
  • ADLINK HSL-DI16DO16-M-NN 16-CH Discrete Input 16-CH Discrete Output Module
  • Adlink cPCI-6770 6U CompactPCI 2.0 Blades
  • ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
  • ADLINK PCI-7200 PCI Motion Control Card Acquisition Card 51-12001-0C20
  • ADLINK TECHNOLOGY EOS-1200/M4G/SSD32G(G) Industrial Systems
  • ADLINK Centralized Motion Controllers PCI-8134
  • ADLINK cPCI-HR6847E/M2G-1 COMPACT PCI BOARD
  • ADLINK PXIE-8638 BUS EXPANSION MODULE
  • ADLINK cPCI-6910 6U CompactPCI 2.0 Blades
  • Adlink NuPRO-E42 51-41808-0A30 Industrial Motherboard
  • ADLINK IH61-AA400-A4A1E (IMB-M40H) Industrial Motherboard
  • ADLINK PCIe-GIE64+ GigE Vision Frame Grabber Card
  • ADLINK MXC-6322D(G) Industrial Fanless Computer working
  • ADLINK CPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Module
  • Adlink cPCI-8168 Advanced 6U Compact PCI 8-Axis Motion Controller
  • Adlink VME CPU Board cPCI-6626/2710/M4G
  • ADLINK  cPCI-R6200 high-performance 6U CompactPCI Rear Transition Module (RTM)
  • Adlink cPCI-7248 48-CH Opto-22 Compatible Digital I/O Module
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nan
  • ADLINK cPCI-3544 4-Port RS-422/485 Isolated Serial Communications Card
  • Hirschmann MSP30-16040SCZ999HHE2A Manage the basic unit of the industrial DIN-Rail switch
  • Hirschmann MSP30-16040SCY999HHE2A
  • Hirschmann RS20-0400S2S2SDAEHC09.0.00 Management-type industrial fast Ethernet switch
  • Hirschmann Belden OCTOPUS OS20-002800T5T5T5-TBBY999GMSE3S Manageable industrial Ethernet switch
  • HIRSCHMANN OS20-000800T5T5T5-TBBU999H5SE2S
  • HIRSCHMANN RS20-0800M4M4SDAEHC09.0.14 industrial switch
  • Hirschmann RS20-0800T1T1SDAUHC RS20-0800T1T1SDAE
  • Hirschmann MSM20-M2M2M2M2SY9HH9E99.9 Fast Ethernet Media Module
  • HIRSCHMANN RS30-1602T1T1SDAEHC09.0.10 industrial switch
  • HIRSCHMANN MAR1040-4C4C4C4C9999SMMHPHH Managed Etherne
  • HIRSCHMANN MAR1040-4C4C4C4C9999SM9HRHH  Managed Etherne
  • HIRSCHMANN MAR1040-4C4C4C4C9999SM9HPHH05.1.00 industrial switch
  • HIRSCHMANN MM20-P9P9M2T1SAHH Fast Ethernet media module
  • HIRSCHMANN MM20-P9T1T1T1SAHH hot-swappable hybrid media module
  • HIRSCHMANN MM20-Z6Z6T1M2SAHH Fast Ethernet media module
  • HIRSCHMANN MM20-Z6M2M2T1SAHH Fast Ethernet media module
  • HIRSCHMANN MM20-Z6Z6Z6T1SAHH media module.