DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

Product Summary of ABB REF601/REJ601 Feeder Protection and Control Relay

From:ABB | Author:LIAO | Time :2025-08-08 | 427 Browse: | 🔊 Click to read aloud ❚❚ | Share:

# Summary of ABB REF601/REJ601 Feeder Protection and Control Relay Product   ## I. Product Overview   REF601 and REJ601 are relays from ABB's Relion® 605 series, specifically designed for medium and low-voltage distribution network substations and industrial power systems. Among them, **REF601** is a dedicated feeder protection and control relay with circuit breaker control functionality, while **REJ601** is an overcurrent protection relay without circuit breaker control. Both products integrate protection, monitoring, and control functions into one unit. Leveraging ABB's profound expertise in protection and numerical technology, they offer excellent performance and usability in their category, suitable for feeder protection scenarios in primary and secondary distribution networks.   ## II. Core Functions and Configurations   ### 1. Protection Functions   Both relays provide multi-level protection functions and support three application configurations (B, C, D). The core protection functions are as follows:   | Protection Type                | ANSI Code               | Key Function Description                                                                                                                                                                                                 | |--------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Three-phase overcurrent protection | 51P (low-stage), 50P-1 (high-stage), 50P-2 (very high-stage) | Supports Definite Time (DT) and Inverse Definite Minimum Time (IDMT) characteristics, covering short-circuit and overcurrent protection; high-stage can operate instantaneously. The low-stage overcurrent protection supports IEC 61255-3, ANSI C37.112 standard curves, and special RI inverse time curves. | | Ground fault protection         | 51N (low-stage), 50N (high-stage) | Based on external zero-sequence CT or internally calculated residual current; low-stage supports IDMT characteristics, high-stage can operate instantaneously. External measurement accuracy is ±5%, and internal measurement accuracy is ±15%. | | Transformer inrush detection    | 68                      | Identifies inrush current through second harmonic to prevent false tripping during transformer energizing; inrush threshold setting range is 0.2-25×In.                                                                     | | Thermal overload protection     | 49                      | Provides thermal overload protection for feeders, cables, and transformers, calculating temperature rise based on a thermal simulation model, supporting heating/cooling time constant settings (1-300min).                  | | Phase discontinuity protection  | 46PD                    | Monitors the ratio of negative sequence current to positive sequence current (I2/I1); the ratio setting range is 10%-100% to detect open-phase faults.                                                                     | | Negative sequence overcurrent protection | 46                 | Protects against asymmetric loads; start value is 0.1-1.5×In, operation delay is 0.1-300s, suitable for equipment such as motors.                                                                                          | | Circuit breaker failure protection | 50BF/50NBF             | Detects circuit breaker faults; phase current operation value is 0.2-2.0×In, zero-sequence current is 0.1-2.0×In, supporting re-tripping and backup protection delay (0.06-0.5s).                                             | | Auto-reclosing (REF601 only)    | 79                      | Supports up to 4 reclosure shots, with customizable reclosure intervals (0.2-300s) and pulse duration (0.2-20s), suitable for overhead line feeders.                                                                       | ### 2. Configuration Differences   The three application configurations cover different functional scopes to meet diverse scenario requirements:   - **Configuration B**: Basic functions, including non-directional overcurrent and ground fault protection.   - **Configuration C**: Builds on Configuration B by adding thermal overload protection, phase discontinuity protection, and circuit breaker failure protection.   - **Configuration D** (REF601 only): Builds on Configuration C by adding negative sequence overcurrent protection and auto-reclosing functions, suitable for overhead line feeders.   ## III. Application Scenarios   Suitable for incoming and outgoing feeder protection in medium-voltage distribution networks, specifically including:   - Short-circuit, overcurrent, and ground fault protection for overhead lines and cable feeders.   - Main protection for distribution transformers (when paired with inrush detection function).   - Feeder monitoring and control in industrial power systems, especially suitable for compact switchgear and retrofit projects.   ## IV. Hardware and Interfaces   ### 1. Input/Output Specifications   | Type         | Specification Details                                                                                                                                                                                                 | |--------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Analog inputs | 4 CT inputs (3-phase current + 1 ground current), supporting 1A or 5A rated current; thermal withstand capability of 4×In for continuous operation, and 100A (1A CT)/500A (5A CT) for 1 second.                          | | Binary inputs | 4 configurable inputs, supporting 24-240V AC/DC, which can be mapped to signals such as blocking, reset, circuit breaker position, and trip circuit monitoring; input response time is 25ms.                              | | Binary outputs | 6 outputs (2 power outputs + 4 signal outputs), supporting tripping, alarming, status indication, etc. Power output contacts can carry 8A continuously and 30A for 0.5s; signal outputs can carry 6A continuously, with a minimum load of 100mA@24V AC/DC. | ### 2. Local HMI and Operation   - **Local Human-Machine Interface**: Equipped with an alphanumeric LCD display, 6 LED indicators (normal/fault, start, trip, phase fault trip, ground fault trip, trip circuit fault), and navigation keys, supporting multi-language display.   - **Access Control**: Three-level role-based authentication (operator, engineer, administrator) with support for key combination or alphanumeric password protection to prevent unauthorized access.   ## V. Monitoring and Recording Functions   1. **Measurement Functions**: Real-time monitoring of three-phase current, ground current, negative sequence current, thermal level, and operation count; data can be accessed via local HMI or remote communication interface.   2. **Event Log**: Non-volatile memory stores 100 event records with 1ms timestamp resolution, including trip status, I/O status, relay fault codes, etc.; data is retained during power loss.   3. **Fault Recording**: Stores analog data (three-phase current, ground current) of the last 5 trip events with timestamps, supporting post-fault analysis.   4. **Self-Supervision and Testing**: Continuously monitors hardware and software status, issues alarms and blocks protection functions in case of faults to prevent misoperation; supports built-in test mode to verify HMI and output circuits.   5. **Trip Circuit Monitoring**: Real-time monitoring of trip circuit availability, detecting open-circuit faults in the circuit breaker's open/closed state and loss of control voltage.   ## VI. Communication and Control   - **Communication Function**: Optional Modbus RTU or IEC 60870-5-103 protocol, enabling remote monitoring via RS-485 bus (two-wire); communication cards can be added later.   - **Control Function**: REF601 supports local/remote control of circuit breakers (closing/opening) via HMI buttons or communication commands, with 2 dedicated circuit breaker control outputs.   ## VII. Technical Parameters   | Category         | Key Parameters                                                                                                                                                                                                 | |------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Power supply     | 24-240V AC/DC; voltage fluctuation range: AC 85-110%, DC 70-120%; power consumption <5VA; maximum DC ripple 12% (100Hz).                                                                                          | | Environmental conditions | Operating temperature: -25~+55℃; short-time service temperature: -25~+70℃ (<16h); humidity <93% (non-condensing); altitude ≤2000m; transportation and storage temperature: -40~+85℃.                          | | Electromagnetic compatibility | Complies with IEC 61000-4 series standards, with resistance to electrostatic discharge (contact 6kV/air 8kV), surges (common mode 4kV/differential mode 2kV), radio frequency interference (10V/m, 80-1000MHz), etc. | | Mechanical dimensions | Width: 130mm (frame)/121.5mm (case); height: 160mm (frame)/151.5mm (case); depth: 151.5mm; weight: 1.43kg; protection rating: IP54 (front), IP20 (terminal side).                                                | ## VIII. Ordering and Accessories   ### 1. Order Code Composition   The order code consists of 11 digits, with key field meanings as follows:   - 1st digit: Relay type (REF601/REJ601).   - 2nd digit: Standard (ANSI/A or IEC/B).   - 3rd-4th digits: Analog input type (1A/D4 or 5A/E4).   - 7th digit: Communication protocol (Modbus RTU/B, IEC 60870-5-103/C, or none/N).   - 8th digit: Application configuration (B/C/D).   ### 2. Accessories   - Communication card: CIM601BNNNNBANXG (for expanding communication functions).   ## IX. Core Advantages   1. **Compact Design**: Adopts press-fit mounting without additional accessories, suitable for switchgear with limited space.   2. **Flexible Configuration**: Three application configurations cover different protection needs, supporting parameter customization and I/O remapping.   3. **High Reliability**: Comprehensive self-supervision and anti-interference design ensure stable operation in harsh environments.   4. **Usability**: Local HMI supports multi-language and intuitive operation; event and fault records facilitate operation and maintenance analysis.   This product is suitable for feeder and transformer protection in medium and low-voltage distribution networks, as well as overcurrent and control scenarios in industrial power systems, serving as a cost-effective compact protection solution that balances performance and cost.

  • OMRON C200PC-ISA02-DRM-E PLC ISA bus compatible board card
  • OMRON C500-CT012 PLC
  • OMRON C500-NC103-E PLC
  • OMRON C500-NC222-E PLC
  • OMRON C500-PRW05-V1 PLC
  • OMRON C500-PRW06 PROGRAMMABLE CONTROLLER
  • OMRON C500-PS223-E 3G2A5-PS223-E PLC SYSMAC PROGRAMMABLE CONTROLLER
  • OMRON C500-TU001 3G2A5-TU001 PLC PLC
  • OMRON C60H-C1DR-DE-V1 Programmable Controllers
  • OMRON C60H-C5DR-DE-V1 Programmable Controllers
  • OMRON C60H-C6DR-DE-V1 Programmable Controllers
  • OMRON CJ1G-CPU44H CPU module
  • OMRON CJ1G-CPU45H PLC
  • OMRON CJ1M-CPU13-ETN V4.0 PLC PLC
  • OMRON CJ1W-AD041-V1 Analog input uni
  • OMRON CJ1W-CORT21 PLC module
  • OMRON CJ1W-IDP01 Input unit
  • OMRON CJ1W-MCH71 - MECHATROLINK-II
  • OMRON CJ1W-MD261 Digital I/O
  • OMRON CJ1W-NC413 Position control unit
  • OMRON CJ1W-NCF71 Position Control Units
  • OMRON CJ1W-PTS51 Process Simulation I/O Module
  • OMRON CJ1W-PTS52 Process Simulation I/O Module
  • OMRON CJ1W-SCU21-V1 PLC
  • Omron CJ1W-SCU22 Serial Communication Unit
  • OMRON CJ1W-TC001 CJ Series Temperature Control Unit
  • Omron CK3W-AX1515N Motion Controller
  • Omron CP1E-N60DR-D Compact PLC CPU
  • OMRON CP1E-NA20DT1-D PLC PLC
  • OMRON CP1H-X40DT-D plc PLC
  • OMRON CPM2C-S110C-DRT Interface module
  • OMRON CQM1-AD041 PLC
  • SAACKE F‑GDSA‑1 / F‑GDSA‑2 Feuerungsautomaten
  • SAACKE F-GDSA 143303 Controller SHIPS UPS
  • ICS Triplex T8270 Trusted 24 Vdc FanAssembly
  • SCHNEIDER M522220000 SA SM_DO16R 16 DIGITAL OUTPUTS MODULE
  • LENZ EPL10200-W EPZ-10203 CANPT010W3E
  • OMRON CQM1H-ADB21 PLC
  • OMRON CQM1H-CPU61 PLC
  • OMRON CQM1H-MAB42 PLC
  • OMRON CQM1-TC102 CQM1-TC101 PLC
  • OMRON CS1G-CPU44-EV1 PLC
  • OMRON CS1G-CPU44H CPU
  • OMRON CS1H-CPU63-EV1 PLC
  • OMRON CS1H-CPU66-V1 PLC
  • OMRON CS1W-CLK13 PLC communication module
  • OMRON CS1W-EIP21 PLC
  • OMRON CS1W-MAD44 PLC PLC
  • OMRON CS1W-SCU31-V1 CVM1-BC103 PLC
  • Omron CVM1-CPU21-V2 CPU Unit
  • OMRON F150-C10E-2 Vision Controller
  • OMRON F150-C15E-3 Vision Controller
  • OMRON F160-C15E VISION MATE CONTROLLER
  • OMRON F500-C10-ETN F500-C15-ETN Vision Sensor
  • OMRON F500-VS F500-S1
  • OMRON FH-3050 FH Vision Controller
  • Omron FQ2-S25050F PLC Smart Camera
  • Omron FQM1-MMA22 Motion Module
  • OMRON GRT1-TS2P Temperature Module
  • OMRON H8PR-24 Cam Positioner
  • OMRON IDSC-C1DR-A-E Controller
  • OMRON K3HB-HTA-DRT1 Temperature Panel Meter
  • Omron KM-N1-FLK Power Detector
  • OMRON CJ1G-CPU43H CPU
  • OMRON NA5-7W001S-V1 NA5-9W001B-V1 NA5-12W101B-V1 Graphic panel
  • OMRON NA5-9W001B-V1 Graphic panel
  • OMRON NB10W-TW01B INTERACTIVE DISPLAY
  • OMRON NB7W-TW01B +CP1L-EL20DR-D Complete Power Panel
  • OMRON NB7W-TX01B INTERACTIVE DISPLAY PLC
  • Omron NE1A-SCPU02 Network Controller
  • OMRON NA5-7W001B-V1 NA5-7W001S-V1 NA5-9W001B-V1 NA5-12W101B-V1 touch screen
  • Omron NS5-SQ00B-V2 NS5-SQ00-V2 NS5-SQ01-V2 NS5-SQ01B-V2 touch display panel
  • Omron NJ301-1100 Programmable Logic Controller
  • OMRON NJ501-1300 CUP Unit Programmable Controller
  • Omron NS12-TS01B-V2 Interactive Display
  • OMRON NSJW-ETN21 ETHERNET HMI
  • OMRON NT10S-SF121 PLC
  • OMRON NT20S-ST121-EV3 Touch Screen
  • Omron NX1P2-1140DT-BA Programmable Controller
  • OMRON 3G3MV-P10CDT3-E RS422/485 INVERTER BOARD
  • Omron C500-ID219 3G2A5-ID219 System Microprocessor
  • Omron PLC B7AM-8B16
  • OMRON PLC Module CJ1W-AD081-V1
  • OMRON R88D-HS10 PLC
  • OMRON R88D-HT10 plc
  • OMRON R88D-KN01H-ML2 Servos G5-series
  • OMRON R88M-H10030-B plc
  • OMRON R88S-H306G plc PLC
  • Omron Relay G9SX-GS226-T15-RT
  • Omron S8AS-24006N S8AS Smart Power Supply FNIP
  • Omron Safety Input Unit NX-SIH400
  • OMRON SYSMAC SCY-P1 Sequential Controller
  • OMRON SYSMAC SCY-P0 13E Sequential Controller
  • OMRON NS8-TV00B-V2 NS8-TV00-V2 NS8-TV00B-ECV2 NS8-TV00-ECV2 touch display Panel
  • Omron V680-CA5D02-V2 Programmable Controller
  • OMRON SGDH-04AE-OY Servo Drive
  • OMRON SGDH-10DE-OY Servo Drive
  • OMRON SGDS-02A12A PLC + SGMAS-C2ACA21
  • OMRON SGMPH-04AAA61D-OY Servo Motor
  • Omron ZFV-CA40 Smart Sensor Amp Unit 24VDC 0.8A
  • OMRON ZFV-NX1 CFP0260 ZFV-A20 VISION CONTROL PANEL
  • OMRON ZFX-C15 SMART SENSOR AMP UNIT, Vision Sensor LCD
  • OMRON ZFX-C20/25-CD SMART SENSOR AMP UNIT, Vision Sensor LCD
  • OMRON-DIGITAL TEMPERATURE CONTROLLER E5AC-CX4A5M-014 r
  • ABB PFVL141V-2.0MN is an industrial-grade, rectangular roll force load cell
  • ABB PFVL141V-1.6MN is an industrial-grade, rectangular roll force load cell
  • ABB PFVL141V-1.25MN high-performance, rectangular roll force load cell
  • ABB PFVL141V-1.0MN high-precision, heavy-duty rectangular load cell
  • ABB PFVL141V-0.8MN high-precision, heavy-duty rectangular load cell
  • ABB PFVL141V-0.63MN high-precision, heavy-duty rectangular load cell
  • GE 151X1202YE08PP08 Panel of the case / Structural component
  • GE 151X1212HB01MG02 Integrated LCI Controller (Old Model)
  • GE 151X1212GC01PC02 LCI Static Startup Controller
  • GE 151X1235FD01PK01 High-speed Digital Input Interface Board
  • GE 151X1215DK01PC01 Signal Processing / Amplification Board
  • GE 151X1238WP99BK01 6-pulse LCI power conversion module
  • GE 151X1225DF01PC03RA - Power Conversion / Drive Regulation Board
  • GE 151X1225DE03PC01 Drive Control Board (Terminal Control)
  • GE 151X1215GD01SA21 Gate Driver Board
  • GE 151X1235BC11WK01 - Network Management Industrial Switch (10/100M)
  • GE 151X1235BC01SA41 Enhanced 10-port switch (redundant)
  • GE 151X1235BC01SA01 10 Industrial Ethernet Switches
  • GE 151X1235DC85PC08 High-speed Digital Input Card (32DI)
  • GE 151X1233DB01SA01R4 Wind turbine pitch control I/O blue box
  • GE 151X1235DB01SA01 16DI+16DO I/O Panel
  • ABB 3BUS213621-001 SBC Assembly
  • ABB 3BUS212310-002 WEIGHT xP V2 DILUTION DRIVE MODULE
  • ABB U3BUS212310-001 Weight xPV2 Slice Drive Module