DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

GESPEEDTRONIC™ MARK V GAS TURBINE CONTROL SYSTEM

From:GE | Author:LIAO | Time :2025-08-19 | 552 Browse: | 🔊 Click to read aloud ❚❚ | Share:

INTRODUCTION

The SPEEDTRONIC™ Mark V Gas Turbine

Control System is the latest derivative in the

highly successful SPEEDTRONIC™ series.

Preceding systems were based on automated turbine control, protection and sequencing techniques dating back to the late 1940s, and have

grown and developed with the available technology. Implementation of electronic turbine control, protection and sequencing originated with

the Mark I system in 1968. The Mark V system is

a digital implementation of the turbine automation techniques learned and refined in more

than 40 years of successful experience, over 80%

of which has been through the use of electronic

control technology.

The SPEEDTRONIC™ Mark V Gas Turbine

Control System employs current state-of-the-art

technology, including triple-redundant 16-bit

microprocessor controllers, two-out-of-three voting redundancy on critical control and protection parameters and Software-Implemented

Fault Tolerance (SIFT). Critical control and protection sensors are triple redundant and voted

by all three control processors. System output

signals are voted at the contact level for critical

solenoids, at the logic level for the remaining

contact outputs and at three coil servo valves for

analog control signals, thus maximizing both

protective and running reliability. An independent protective module provides triple redundant hardwired detection and shutdown on

overspeed along with detecting flame. This module also synchronizes the turbine generator to

the power system. Synchronization is backed up

by a check function in the three control processors.

The Mark V Control System is designed to fulfill all gas turbine control requirements. These

include control of liquid, gas or both fuels in

accordance with the requirements of the speed,

load control under part-load conditions, temperature control under maximum capability

conditions or during startup conditions. In addition, inlet guide vanes and water or steam injection are controlled to meet emissions and operating requirements. If emissions control uses

Dry Low NOx techniques, fuel staging and combustion mode are controlled by the Mark V system, which also monitors the process.

Sequencing of the auxiliaries to allow fully automated startup, shutdown and cooldown are also

handled by the Mark V Control System. Turbine

protection against adverse operating situations

and annunciation of abnormal conditions are

incorporated into the basic system. The operator interface consists of a color

graphic monitor and keyboard to provide feedback regarding current operating conditions.

Input commands from the operator are entered

using a cursor positioning device. An arm/execute sequence is used to prevent inadvertent turbine operation. Communication between the

operator interface and the turbine control is

through the Common Data Processor, or <C>, to

the three control processors called <R>, <S> and

<T>. The operator interface also handles communication functions with remote and external

devices. An optional arrangement, using a

redundant operator interface, is available for

those applications where integrity of the external data link is considered essential to continued plant operations. SIFT technology protects

against module failure and propagation of data

errors. A panel mounted back-up operator display, directly connected to the control processors, allows continued gas turbine operation in

the unlikely event of a failure of the primary

operator interface or the <C> module.

Built-in diagnostics for troubleshooting purposes are extensive and include “power-up,”

background and manually initiated diagnostic

routines capable of identifying both control

panel and sensor faults. These faults are identified down to the board level for the panel and

to the circuit level for the sensor or actuator

components. The ability for on-line replacement

of boards is built into the panel design and is

available for those turbine sensors where physical access and system isolation are feasible. Set

points, tuning parameters and control constants

are adjustable during operation using a security

password system to prevent unauthorized access.

Minor modifications to sequencing and the

addition of relatively simple algorithms can be

accomplished when the turbine is not operating.

They are also protected by a security password.

A printer is included in the control system

and is connected via the operator interface. The

printer is capable of copying any alpha-numeric

display shown on the monitor. One of these displays is an operator configurable demand display that can be automatically printed at a

selectable interval. It provides an easy means to

obtain periodic and shift logs. The printer automatically logs time-tagged alarms, as well as the

clearance of alarms. In addition, the printer will

print the historical trip log that is frozen in

memory in the unlikely event of a protective

trip. The log assists in identifying the cause of a

trip for trouble shooting purposes.

The statistical measures of reliability and availability for SPEEDTRONIC™ Mark V systems have

quickly established the effectiveness of the new

control because it builds on the highly successful SPEEDTRONIC™ Mark IV system.

  • GE IS200AEPBH1B IS200AEPBH1B‑REV‑AA Pitch-Charger Control PCB Board
  • GE IS200EDEXG1ADA EX2100 SCR Trigger Control Board
  • GE 151X1207CK01SA01 IS200EDEXG1A EX2100 SCR
  • GE 151X1233DD02SA02 IS200AEPBH1B - Variant for pitch control charger assembly
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01R | IS200AEPBH1B 10KW Converter
  • GE 151X1233DD01SA02 Pitch Battery Charger (109W6931P001)
  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)
  • SHINKAWA MODEL VM-5G  SINGLE UNIT   INSTRUMENT RACK
  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa CPP-111 P-25-59A P-25-59B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP,51304386‑100.MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE,51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732-001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell TDC‑3000 BASIC,XLCNE2 LCN Extender,51305508‑100.Coaxial LCN
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module