DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

FUJICommunication Unit SpecificationDeviceNet

From:FUJI | Author:LIAO | Time :2025-08-19 | 435 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Notes on Safe Usage

In this manual, you will find various notes categorized under the following levels with the signal words “DANGER,” and 

“CAUTION.”

Note that there is a possibility that the item listed with may have serious ramifications.

[General Notes]

• Never bundle control cables and input/output cables with high-voltage and large-current carrying cables such as 

power supply cables. Keep these cables at least 200 mm away from the high-voltage and large-current carrying 

cables. Otherwise, malfunction may occur due to noise.

• Plug connectors or sockets of the unit in the correct orientation. Otherwise, it may cause a malfunction.

DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious 

injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or 

moderate injury and could cause property damage.

• Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection. 

Otherwise, electrical shock or damage may occur.

• Never touch any terminals while the power is on. Electric shock hazard.

• Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found. 

Failure to do so may lead to fire, damage or malfunction.

• For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile 

installations, please consult your local distributor.

• Operate (or store) the unit under the conditions indicated in this manual and related manuals. Failure to do so 

could cause fire, malfunction, physical damage or deterioration.

• Understand the following environmental limits for use and storage of the unit. Otherwise, fire or damage to the unit 

may result.

- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding fluids or 

cutting oil can come into contact with the unit.

- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight.

- Avoid locations where excessive dust, salt, and metallic particles are present.

- Avoid installing the unit in a location where vibration or physical shock may be transmitted.

• Tighten mounting screws equally to a torque of 0.5 to 0.7 N•

m. Improper tightening of screws may result in fire, 

malfunction, or trouble.

• Do not attempt to repair, overhaul or modify the unit at your site. Ask Hakko Electronics or the designated 

contractor for repair. Otherwise, it may cause a malfunction.

• Hakko Electronics Co., Ltd. is not responsible for any damages resulting from repair, overhaul or modification of 

the unit that was performed by an unauthorized person.

• Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection.

• At the time of disposal, the unit must be treated as industrial waste.

• Before touching the unit, discharge static electricity from your body by touching grounded metal. Excessive static 

electricity may cause malfunction or trouble.

• DeviceNet is an open field network that aids in interconnecting individual control devices, such as 

PLCs, computers, sensors, or actuators.

For more information on the DeviceNet, refer to the DeviceNet Specification issued by ODVA*.

* Open DeviceNet Vendor Association, Inc. 

ODVA, Open DeviceNet Vendor Association, Inc., is an independent organization that controls 

the DeviceNet specifications. ODVA is formed by vendors with the objective of achieving 

widespread use of its DeviceNet globally

• With a communication interface unit CU-07 installed on the V series, it can communicate with other 

components as a slave of the DeviceNet.

• The CU-07 supports the I/O message polling function.

Specifications

This chapter describes the specifications for the communication interface unit CU-07.

General Specifications

Performance Specifications

System Composition Example

Items Specifications

Vendor ID 734

Product Code 0001 (HEX)

Connector Screw connector

I/O Specification Compliant with the DeviceNet protocol

Baud Rate 125 k/250 k/500 kbps (changeable with the DIP switch)

Transmission 

Distance

Baud rate

Max. network length Branch line 

length

Overall 

branch line 

length Thick cable Thin cable

125 kbps 500 m 100 m 6 m 156 m

250 kbps 250 m 100 m 6 m 78 m

500 kbps 100 m 100 m 6 m 39 m

Communication 

Function I/O message: Polling


Names and Settings of Components

DeviceNet connector

This connector is used to connect the communication cable.

2. DIP switch

Choose a node address and baud rate. For more information, refer to page 7.

3. LED: NS

This LED indicates the network status. For more information, refer to page 8.

4. LED: MS

This LED indicates the node status. For more information, refer to page 8.

LED Indications

MS: Module status

: Extinguished : Illuminated : Blinking

NS: Network status

: Extinguished : Illuminated : Blinking

Color Status Contents Solution

- Power not supplied • Check that the CU-07 is installed 

correctly and turn on the V series.

Green Delivery test mode -

  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card
  • Adlink Centralized Motion Controllers PCI-8164
  • ADLINK PCI-7230/33/34 32-CH Isolated DIO PCI Cardsrd
  • ADLINK NUPRO-E320DV/NUPRO-E320 industrial control motherboard
  • Adlink PCI-8154 Advanced 4-axis Servo & Stepper Motion Controller
  • Adlink cPCI-3534/3538-S Series 4/8-port Asynchronous Serial Communications Modules
  • ADLINK Adlink Digital I/O PCI-7396
  • ADLINK 6U Rear Transition Modules cPCI-R6700 Series
  • ADLINK cPCI-6700B Industrial Control Board
  • ADLINK NuPRO-965/ NuPRO-965LV PICMG Single Board Computers
  • ADLINK HSL-DI16DO16-M-NN 16-CH Discrete Input 16-CH Discrete Output Module
  • Adlink cPCI-6770 6U CompactPCI 2.0 Blades
  • ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
  • ADLINK PCI-7200 PCI Motion Control Card Acquisition Card 51-12001-0C20
  • ADLINK TECHNOLOGY EOS-1200/M4G/SSD32G(G) Industrial Systems
  • ADLINK Centralized Motion Controllers PCI-8134
  • ADLINK cPCI-HR6847E/M2G-1 COMPACT PCI BOARD
  • ADLINK PXIE-8638 BUS EXPANSION MODULE
  • ADLINK cPCI-6910 6U CompactPCI 2.0 Blades
  • Adlink NuPRO-E42 51-41808-0A30 Industrial Motherboard
  • ADLINK IH61-AA400-A4A1E (IMB-M40H) Industrial Motherboard
  • ADLINK PCIe-GIE64+ GigE Vision Frame Grabber Card
  • ADLINK MXC-6322D(G) Industrial Fanless Computer working
  • ADLINK CPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Module
  • Adlink cPCI-8168 Advanced 6U Compact PCI 8-Axis Motion Controller
  • Adlink VME CPU Board cPCI-6626/2710/M4G
  • ADLINK  cPCI-R6200 high-performance 6U CompactPCI Rear Transition Module (RTM)
  • Adlink cPCI-7248 48-CH Opto-22 Compatible Digital I/O Module
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nan
  • ADLINK cPCI-3544 4-Port RS-422/485 Isolated Serial Communications Card
  • Hirschmann MSP30-16040SCZ999HHE2A Manage the basic unit of the industrial DIN-Rail switch
  • Hirschmann MSP30-16040SCY999HHE2A
  • Hirschmann RS20-0400S2S2SDAEHC09.0.00 Management-type industrial fast Ethernet switch
  • Hirschmann Belden OCTOPUS OS20-002800T5T5T5-TBBY999GMSE3S Manageable industrial Ethernet switch
  • HIRSCHMANN OS20-000800T5T5T5-TBBU999H5SE2S
  • HIRSCHMANN RS20-0800M4M4SDAEHC09.0.14 industrial switch
  • Hirschmann RS20-0800T1T1SDAUHC RS20-0800T1T1SDAE
  • Hirschmann MSM20-M2M2M2M2SY9HH9E99.9 Fast Ethernet Media Module
  • HIRSCHMANN RS30-1602T1T1SDAEHC09.0.10 industrial switch
  • HIRSCHMANN MAR1040-4C4C4C4C9999SMMHPHH Managed Etherne
  • HIRSCHMANN MAR1040-4C4C4C4C9999SM9HRHH  Managed Etherne
  • HIRSCHMANN MAR1040-4C4C4C4C9999SM9HPHH05.1.00 industrial switch