DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

LAUERfor the operating consoles PCS 009, PCS 090, PCS 095, PCS 095.1

From:LAUER | Author:LIAO | Time :2025-08-20 | 575 Browse: | 🔊 Click to read aloud ❚❚ | Share:

for the operating consoles

PCS 009, PCS 090, PCS 095, PCS 095.1

The operating consoles PCStopline offer the

highest degree on perfection, unparalled in

design and function. PCStopline keeps everything under control - from the PCSmini to the

PCSmaxi, with a superior operating culture and

an unlimited setup freedom.

PCS, the first programmable operating console

with a large selection of "ready-to-use" operating functions or operating tools which are

simply selected via instructions. You can realize

even the most unuasal operating requests at

ease and in a minimum of time.

Today this way and tomorrow that way

One standard hardware for virtually thousands

of different operating situations. Without extensive wiring and dozens of I/O points.

PCS for operating. What else?

■ Machine operation using 8 (PCS 009, PCS 090) or 16 (PCS 095, PCS 095.1)

freely assignable keys. These F01 to F08/F16 labeled keys can be application

specifically inscribed and are provided to the controller as status bits.

■ Machine operation using 4 (PCS 009), 16 (PCS 090) or 32 (PCS 095, PCS

095.1) freely usable LEDs. These can be assigned the indicating states ON,

DARK, FLASHING, and INVERSE FLASHING. A green and a yellow LED is allocated

to each function key.

■ Display of fixed texts with integrated variable values. The values can be

represented selectably as numerical values or in text format.

■ Representation of the contents of 233 words as variables. In addition, 650

external variables can be defined. 9 variable formats (from bit to timer) are

available.

■ 3 text groups, 128 operating texts as menu and idle texts, 128 message texts

with up to 332 lines, 5 help texts with up to 32 lines.

■ 127 menus with 255 menu nodes each for any menu configurations.

■ 4 different deletion modes. For every message, 1 of 4 possible deletion modes

can be selected.

■ Modification of the content of any word within the transfer area. Using the

integrated editor all possible representation formats can be setup.

■ 7 priority levels for idle text up to help text, 3 message priorities Information,

Warning, Fault. This working-condition related management significantly offloads the programmable controller program.

■ Monitoring of rising or falling edges of 128 consecutive bits. The assignment

of texts, the manage-ment of 3 priority levels (Information, Warnings, and Faults),

keeping the timely sequence as much as possible, organization of the FIRST

MESSAGE, LAST MESSAGE, and CYCLIC DISPLAY, the individually settable deletion behaviour, and the representation formats NORMAL and FLASHING are tasks

which are managed by the PCS by itself.

■ Communication monitoring (wire-break, short circuit). A very efficient data

transfer is secured by the integrated priority management in connection with the

intelligent package length optimization, the high thruput rate and the fault tole

Operator Panel PCS 009

1 = LCD-Display, 4 lines each with 40 characters

2 = Function keys (also as soft keys) F1...F8 with a

greem message LED

3 = 10 key keyboard for nominal value input

4 = cursor and control keys for menus and nominal

value input

5 = Switch key (Shift key) for function keys (F1..F4,

F5..F9)

6 = Important information LEDs on the PCS status

7 = Reset key

8 = DIL switch for the PCS 009

9 = Volume for acoustic signal

J = Serial interface RS 232/TTY for communication

K = Serial interface RS 422/RS 485 for communication

L = Operating voltage terminals

M = Fuse with reserve fuse

Operator Panel PCS 090

1 = LCD-display, 2 lines each with 40 characters

2 = Function keys (also as soft keys) F1...F8 with a

yellow and green message LED

3 = 10 key keyboard for nominal value input

4 = Cursor keys with LED and cursor control keys for

menus and nominal value input

5 = Important information LED's on the PCS status

6 = Reset key

7 = DIL-switch for the PCS 090

8 = Volume for acoustic signal

9 = Serial interface RS 232/TTY for the communication

J = Serial interface RS 422/RS 485 for the

communication

K = Operating voltage terminals

L = Fuse with reserve fuse

Operator Panel PCS 095/PCS 095.1

1 = LCD-display, 4 lines each with 40

characters

2 = Function keys (also soft keys) F1...F8

each with a yellow and a green

message LED

3 = Function keys F9...F16 each with a

yellow and a green mesage LED

4 = Ten key keyboard for nominal value

input

5 = Cursor key with LED and control key for

menu and nominal value input

6 = Important information LEDs on the PCS

status

7 = Reset key

8 = DIL switch for the PCS 095

9 = Volume for acoustic signals

J = Serial interface RS 232/TTY for the

communication

K = Serial interface RS 422/RS 485 for

the communication

L = Serial interface RS 232/TTY for the

programming and for the PCS 095.1

as Printer interface

M = Operating voltage terminals

N = Fuse with reserve fuse

Communication between any PLC and the PCS occurs as follows:

The PCS writes in predetermined word areas of the PLC, functions or nominal values,

which the PLC then reads and interprets.

The PLC writes in predetermined word areas functions or actual values, which are

automatically read and interpreted by the PCS. Independently of the PLC there are

maximum 256 words of 16 bit, that is to say 4096 inputs / outputs for the PCS/PLC

  • GE IS200AEPBH1B IS200AEPBH1B‑REV‑AA Pitch-Charger Control PCB Board
  • GE IS200EDEXG1ADA EX2100 SCR Trigger Control Board
  • GE 151X1207CK01SA01 IS200EDEXG1A EX2100 SCR
  • GE 151X1233DD02SA02 IS200AEPBH1B - Variant for pitch control charger assembly
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01R | IS200AEPBH1B 10KW Converter
  • GE 151X1233DD01SA02 Pitch Battery Charger (109W6931P001)
  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)
  • SHINKAWA MODEL VM-5G  SINGLE UNIT   INSTRUMENT RACK
  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa CPP-111 P-25-59A P-25-59B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP,51304386‑100.MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE,51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732-001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell TDC‑3000 BASIC,XLCNE2 LCN Extender,51305508‑100.Coaxial LCN
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module