DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

IBABM-DPM-S Simulation mode and mirror mode

From:IBA | Author:LIAO | Time :2025-08-20 | 744 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:


About this manual 

This manual is a supplement to the „ibaBM-DPM-S Profibus Sniffer“ manual and describes the use and the operation of ibaBM-DPM-S in simulation and mirror mode. 

1.1 Target group 

This manual addresses in particular the qualified professionals who are familiar with 

handling electrical and electronic modules as well as communication and measurement 

technology. A person is regarded to as professional if he/she is capable of assessing 

safety and recognizing possible consequences and risks on the basis of his/her specialist training, knowledge and experience and knowledge of the standard regulations. 

1.2 Notations 

The following designations are used in this manual

Action Notations 

Menu command Menu „Logic diagram“ 

Call of menu command „Step 1 – Step 2 – Step 3 – Step x” 

Example: 

Select menu „Logic diagram – Add – New logic 

diagram” 

Keys <Key name> 

Example: <Alt>; <F1> 

Press keys simultaneously <Key name> + <Key name> 

Example: 

<Alt> + <Ctrl> 

Buttons <Button name> 

Example: 

<OK>; <Cancel> 

File names, Paths „File name“, „Path” 

Example: 

„Test.doc

The non-observance of this safety information may result in an imminent risk of death or

severe injury: 

 By an electric shock! 

 Due to the improper handling of software products which are coupled to input and 

output procedures with control function! 

The non-observance of this safety information may result in a potential risk of death or 

severe injury! 

The non-observance of this safety information may result in a potential risk of injury or 

material damage! 

Note 

A note specifies special requirements or actions to be observed. 

Important note 

Note if some special features must be observed, for example exceptions from the rule. 

Tip 

Tip or example as a helpful note or insider tip to make the work a little bit easier. 

Other documentation 

Reference to additional documentation or further reading

Introduction 

Note 

The following description gives information about the operation of ibaBM-DPM-S in 

simulation and mirror mode. 

The basic handling of ibaBM-DPM-S should be known. 

Other documentation 

For the precise description of the handling of ibaBM-DPM-S please observe the 

ibaBM-DPM-S manual. 

Simulation mode 

The simulation mode is designed to test the software and the configuration of a DP 

master station, although the Profibus environment is physically not available. 

When working in simulation mode ibaBM-DPM-S is able to simulate slaves, which can 

be addressed by the master, but which are not present at the bus. Any master station 

(e. g. Simatic S7, ibaLogic with SST card) can be used as master, when it is accordingly configured. The corresponding I/O data of the simulated slaves can be generated 

by a simulation program (e. g. ibaLogic). 

Mirror mode 

The mirror mode is helpful during migration to a new control system (soft revamp). A 

new DP master system can be tested in parallel to a running master system, which is 

still in use. 

As sniffer ibaBM-DPM-S reads all data of the slaves connected at Profibus interface 1. 

The data of the slaves are mirrored to the Profibus interface 2, where the second (new) 

master is connected. All data is available for the second master, just as if it would be 

the master of the Profibus line. ibaPDA can record the data of both systems, and the 

user can compare both systems. 

Supplementary licenses are needed for the use of simulation and mirror mode. The 

simulation mode licenses are scaled according to the number of simulated slaves. 

Please contact the iba support. 

Simulation mode 

3.1 Requirements 

 ibaBM-DPM-S firmware beginning with version B7. 

 Simulation mode license. The license can be purchased later on and activated via 

the ibaBM-DPM-S Web interface. 

Order number simulation mode license: 13.321010 

 Simulation PC with TCP/IP connection to ibaBM-DPM-S and any Internet browser 

e. g. Internet Explorer, Mozilla Firefox. 

3.2 Simulation mode configuration 

All necessary settings are to be done in the ibaBM-DPM-S Web interface, which requires a PC with a TCP/IP connection to ibaBM-DPM-S. 

Other documentation 

How to connect the PC and the device, please observe the "ibaBM-DPM-S" manual. 

Tip 

Basically the USB interface can also be used for simulation. But iba highly recommends 

the TCP/IP connection via Ethernet in order to minimize the reaction times of the slaves.

After having opened the website, the modes available on the device are displayed on 

the “Info” page. 

When simulation mode is not available, it has to be activated. You will receive the necessary license key by E-Mail after purchasing at iba.

Enter the license key: 

1. Login as user „admin“ on the „Admin“ page. 

2. Enter the license key under „Activate simulation, mirror or redundancy mode“ in the 

  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170    CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module, Microsoft Windows Embedded Standard 7 P
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module, Microsoft Windows Embedded Compact 7
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190  CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170    CPU module
  • Beckhoff CX5230-0100   CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC
  • Beckhoff  CX5130-0163 CPU module
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161 CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143    CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125  CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121    CPU module
  • Beckhoff CX5130-0115    CPU module
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112 CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100 CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return
  • SAUTER ASF113F122 Damper actuator with spring return