AMAT  0010-23716  Cavity integrated piping and signal interface assembly
❤ Add to collection

AMAT 0010-23716 Cavity integrated piping and signal interface assembly

AMAT  0010-23716  Cavity integrated piping and signal interface assembly

4600.00
¥2500.00
¥2500.00
¥2500.00
Weight:2.000KG
Description

AMAT  0010-23716  Cavity integrated piping and signal interface assembly


AMAT 0010-23716 is a high-precision Chamber Manifold and Signal Interface Assembly manufactured by Applied Materials.

It is a critical hardware integration component used primarily in the Endura,

Centura, and Producer semiconductor processing platforms

This module acts as the physical and electrical "junction box" for the process chamber, coordinating gas flow control (MFC) signals, sensor data, and vacuum interlock safety protocols.

Designed for 200mm and 300mm wafer fabrication, the 0010-23716 is engineered to handle the high-speed data acquisition required for sub-10nm process nodes while maintaining a robust physical connection to the chamber's gas box.

Technical Parameter Table

ParameterSpecification
Part Number0010-23716
Component CategoryChamber Interface Manifold / I/O Control
System CompatibilityCentura, Endura, Producer Platforms
Input Voltage+24V DC / +/-12V DC (System Logic & Field Power)
Connector TypeMulti-pin High-Density D-Sub and Ribbon Interface
Operating Temp0°C to +60°C (Optimized for Sub-Fab/Cleanroom)
Housing MaterialAnodized Aluminum / Shielded Steel Enclosure
Signal DensityHigh-density Analog and Digital I/O paths

Related Models

The 0010-23716 is typically found integrated with these associated AMAT control components:

AMAT 0010-series: Various gas box manifolds and chamber controllers.

AMAT 0190-series: RF Control and Interface modules.

AMAT 0200-series: Backplane and Signal Distribution PCBs.

AMAT 0100-series: VMEbus CPU and Memory boards.

Application Cases

PVD/CVD Gas Control: Distributing setpoint signals to multiple Mass Flow Controllers (MFCs) to ensure precise chemical ratios during film deposition.

Vacuum Pressure Monitoring: Managing real-time data from Baratron gauges and pressure transducers to maintain sub-mTorr stability.

Heater Pedestal Coordination: Bridging the connection between pedestal thermocouples and the remote temperature controller for ±0.5°C uniformity.

Safety Interlocks: Processing vacuum-ready and slit-valve-open signals to prevent robotic transfer errors during high-vacuum cycles.

Product Advantages and Features

EMI/RFI Shielding: Encased in a rugged, shielded housing to protect sensitive low-voltage signals from the intense electrical noise of nearby RF generators.

Modular Integration: Designed as a "Plug-and-Play" manifold, allowing field service engineers to replace the entire I/O block during Preventative Maintenance (PM) with minimal tool downtime.

High Signal Integrity: Features gold-plated pins and high-spec internal wiring to prevent oxidation and signal attenuation in corrosive fab environments.

Diagnostic Accessibility: Integrated test points allow for voltage and signal verification without the need to dismantle the chamber’s primary cable harness.

OEM Precision: Manufactured to the exact tolerances required for AMAT's robotic calibration, ensuring consistent "handshake" signals between the chamber and the mainframe.

Installation and Maintenance

SANKYOPC10021
SANMOTIONPB3A003P200
SANYOPMDAA1SFC20R
SANYOSTNM-DR-160B(U)
SANYOSTNM-DR-250B(U)
SANYOP30B04010PCKST
SARTORIUSMDB-5E
SARTORIUSMDB-5E
SATCM3141-02-03   CX3149-05
SATCM3142-01-03   CX3147-04
SATRM3141-01-02   CM3141-01-02
SAUTERAVM234SF132
SBS82002077
SBSP2-100BT-ER/91515902-ER
SBS82002070
SBSVIPC616
SBSPMC-HS-SERIAL
SBSVME-IP-CARRIER   VIPC616 91611524
SBSPFSK165   3BSE027778R1 VP74201-933CW07

Installation

ESD Protocol: Wear a grounded wrist strap. The internal circuitry contains CMOS logic highly susceptible to static discharge.

Mounting: Secure the manifold to the chamber bulkhead or gas box frame using the specified torque to maintain a consistent chassis ground.

Cable Management: Ensure all high-density D-sub connectors are properly seated and the thumb-screws are tightened to prevent vibration-induced "intermittent" signal faults.

Maintenance

Visual Inspection: During scheduled wet cleans, check for signs of "pitting" on the connectors or discoloration that may indicate excessive heat from nearby heaters.

Cleaning: Use only 99% anhydrous Isopropyl Alcohol (IPA) and lint-free swabs on external connectors. Do not allow liquid to enter the shielded housing.

Verification: Use the system’s diagnostic software (e.g., VHP or G6) to verify all I/O channels are reporting correctly after any reinstallation.

Unique Product Description

The AMAT 0010-23716 is the "Nerve Center" of the Applied Materials chamber environment.

While the mainframe handles the high-level logic, this manifold assembly ensures that every micro-adjustment in gas flow or pressure is executed with absolute fidelity.

It is a critical link in the chain of high-volume manufacturing, built to survive the brutal 24/7 duty cycles of the world's most advanced semiconductor fabs while maintaining the atomic-level precision that modern microchip production demands.


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI