AMAT   0190-02076   Water Leak Detector / CCM Board
❤ Add to collection

AMAT 0190-02076 Water Leak Detector / CCM Board

AMAT   0190-02076   Water Leak Detector / CCM Board

4500.00
¥3500.00
¥3500.00
¥3500.00
Weight:2.000KG
Description

AMAT   0190-02076   Water Leak Detector / CCM Board


AMAT   0190-02076   Water Leak Detector / CCM Board

Introduction

The AMAT 0190-02076 is a CCM (Chamber Control Module) Water Leak Detector PCB.

In semiconductor manufacturing, liquid cooling is essential for high-power components like RF generators and electrostatic chucks.

This board acts as a critical safety interlock, providing real-time moisture detection within the tool's mainframe or gas box.

It is designed to trigger an immediate system shutdown (Interlock) if a leak is detected, preventing catastrophic damage to high-voltage electronics and vacuum integrity.

2. Technical Parameter Table

ParameterSpecification
ManufacturerMKS Instruments / TeNTA (for Applied Materials)
Part Number0190-02076
OEM Model NumberAS00021-02 / AS00021-01 (TeNTA)
Component TypeWater Leak Detector / CCM Board
Compatible PlatformsEndura, Centura, Producer, eMax CT+
FunctionLiquid detection and interlock signaling
DimensionsApprox. 130mm x 210mm x 20mm
WeightApprox. 0.5 kg

3. Related Models

The 0190-02076 is often integrated into larger control modules or found alongside these interface boards:

AMAT 0110-02076: The primary assembly designation for this detector board.

AMAT 0190-02362: Mainframe Interface Relays Board (often receives the leak signal).

AMAT 0190-23441: Interlock Module (300mm Enabler tools).

AMAT 0010-26286: Controller Assembly CCM DPS232 (which often houses this PCB).

4. Application Cases

RF Generator Cooling: Monitoring the water lines that cool the RF matching networks to prevent electrical arcing from leaks.

Heat Exchanger Oversight: Used in Centura and Producer systems to monitor the secondary cooling loops for the wafer pedestal (Heater/ESC).

Facility Interface: Acting as the "first responder" in the tool's sub-fab or mainframe floor where coolant manifold connections are most prone to vibration-induced leaks.

5. Product Advantages and Features

Rapid Response Time: Designed with high-sensitivity trace patterns to detect even milliliter-scale moisture accumulation.

Failsafe Design: Integrated directly into the tool's hardware interlock string; if the board loses power or fails, the tool defaults to a "Safe" (stopped) state.

Corrosion Resistant: The PCB traces are often gold-plated or specially coated to prevent false positives caused by high-humidity cleanroom environments.

Compact CCM Form Factor: Fits into standard M-type or 3U Compact PCI slots common in AMAT tool racks.

6. Other Models in the Same Series

This board is part of the 0190-XXXXX electronic control series:

0190-02363: Mainframe Interlock 2-Relay Board.

0190-10208: 300mm Mainframe Interface PCB.

0190-34511: DeviceNet Bus Scanner Module (for digital signal reporting).

7. Installation and Maintenance

Installation

ESD Safety: Always wear a grounded wrist strap; the CMOS components on this board are highly sensitive to static.

Slot Alignment: Ensure the PCB is firmly seated in the CCM rack guide rails before engaging the captive screws.

Sensor Connection: Connect the external moisture sensor pads (usually located in the bottom drip pans of the tool) to the input header on the board.

Maintenance

Monthly Test: Manually "trip" the sensor using a damp cloth (if protocol allows) to ensure the software recognizes the leak alarm and triggers the interlock.

Visual Inspection: Check for "creepage" or residue on the board surface which can cause high-impedance shorts and false alarms.

8. Unique Product Description

The AMAT 0190-02076 is the "insurance policy" of a semiconductor tool.

While complex processors manage the chemistry of a wafer, this board performs the humble but vital task of ensuring the tool doesn't "drown" in its own cooling water.

Its presence is the difference between a minor maintenance task and a multi-million dollar hardware loss due to a coolant-induced electrical short.


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI