DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IS200DRTDH1A
❤ Add to collection

IS200DRTDH1A

IS200DRTDH1A
10055.00
¥4548.00
¥4548.00
¥4548.00
Weight:0.000KG
Description
IS200DRTDH1A

Part Number IS200DRTDH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockThe IS200DRTDH1A is an RTD input terminal board developed by General Electric as part of the Mark VI Speedtronic system. This compact board is designed for DIN-rail mounting and offers eight RTD inputs, linking to the VRTD processor board via a single cable. Its design mirrors that of the TRTD terminal board, ensuring compatibility and integration flexibility across different setups. Features Vertical Stacking: The DRTD board allows for vertical stacking on the DIN-rail, optimizing cabinet space by enabling multiple boards to be aligned neatly one above the other. This feature conserves valuable real estate and ensures an organized setup. Scalability: Two DRTD boards can be connected to the VRTD processor board, expanding the system to accommodate up to 16 temperature inputs, making it suitable for more extensive temperature monitoring and control tasks. Simplex Version: Currently, only a simplex version of the board is available. Despite this, its efficient design and features make it a versatile and reliable solution for industrial and commercial temperature management applications. Installation DIN-Rail Mounting: The DRTD board easily slides into a plastic holder designed for DIN-rail mounting, providing a secure and stable placement within the system. RTD Connections: The board includes a Euro-Block type terminal block with 36 terminals permanently affixed, facilitating the connection of up to eight RTDs (Resistance Temperature Detectors). Typically, #18 AWG shielded twisted triplet cables are used for these connections to ensure efficient signal transmission and resistance to interference. Spare Terminals: Terminals 25 through 34 on the block are allocated as spare terminals, offering flexibility for future expansions or modifications without requiring extensive rewiring. Ground Connection: Two screws are dedicated to the SCOM (ground) connection, which should be kept as short as possible to minimize interference and ensure system stability. Operation Noise Suppression: The onboard noise suppression system is similar to that on the TRTD board. The Euro-Block terminal blocks include two screw connections for grounding (SCOM), while an onboard identification chip helps identify the board to the VRTD processor for system diagnostics. Multiplexed Excitation: The board supplies a 10 mA DC multiplexed excitation current to each RTD, supporting both grounded and ungrounded configurations. RTDs can be located up to 300 meters (984 feet) away from the turbine control cabinet, as long as the two-way cable resistance does not exceed 15 ohms. Signal Processing: The RTD signals are processed through a VCO type A/D converter on the VRTD board, which samples signals and excitation currents four times per second in normal mode and 25 times per second in fast mode, synchronizing with the power system frequency. RTD Types and Anomaly Detection: The system supports 15 RTD types, with software-driven linearization providing flexibility in selection. Open and short circuit detection is facilitated by monitoring for values outside the expected range. RTDs with hardware limit issues are temporarily removed from scanning, with channels reactivated after 20 seconds or manually reinstated. This comprehensive setup ensures effective noise suppression, reliable identification, precise signal processing, and proactive anomaly detection, enhancing the overall system's reliability and performance in various temperature monitoring and control scenarios.TERMINAL BOARD

  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200
  • ABB PCS6000 medium voltage wind turbine converter
  • SYSTEM DRIVES PCS6000 ABB
  • ABB PP886 Compact Product Suite hardware selector
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Panel 800 Version 6- PP885
  • ABB IndustrialIT Panel 800 - PP846 Version 5.1
  • ABB IndustrialIT Panel 800 - PP836 Version 5.1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • ABB Advant® Master S100 I/O system
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • GE Reason RT431 GPS Precision-Time Clock
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany (2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • Advant™Automation with MOD 300™ Software
  • ABB MEASUREMENT & ANALYTICS EasyLine EL3000 / EL3060
  • ABB MEASUREMENT & ANALYTICS PGC5000 Process gas chromatograph
  • ABB AC servo motors BSM Series
  • ABB New BSD Series A complete range
  • ABB Advant Controller 110
  • ABB ASTAT® Crane motion controller Version AST10_054
  • ABB-Crane Control System - ASTAT
  • ABB Open Control System Advant Controller 210
  • ABB Open Control System Advant Controller 250
  • ABB Advant Controller 160
  • ABB DSCA33 High Performance Signal Conditioners
  • ABB Advant Controller 70 – Kompakter und leistungsfähiger
  • ABB Advant Controller 31 Hardware 90 Series