range of product
- Flow
Product or component type
- Magnetic flowmeter transmitter
Device application
- To measure the flow of pressure for liquid, gas, steam
Market segment
- Pharmaceutical
Power
Product specific application
- To measure flow with beverage containning solid media
Clean-in-place
Mixing
Batching
Dosing
Device composition
- liner in PFA (perfluoroalkoxy)
electrode in hastelloy
electrode in stainless steel
electrode in titanium
electrode in platinium
electrode in tantalum
Tube diameter - 2.5…150 mm 2.54…152.40 mm communication port protocol - Hart protocol tolerance FOUNDATION fieldbus Modbus Measurement accuracy - +/- 0.3 % of reading with IMT31A +/- 0.2 % of reading with IMT33A drift of the sensitivity - +/- 0.01 % Housing material - Stainless steel Name of test - Vibration Shocks Mounting support - Flange Mounting location - Dierctly connect to the signal converter (with IMT30A) Dierctly connect to the signal converter (with IMT31A) Dierctly connect to the signal converter (with IMT33A) Wall mounting (with IMT30A) Wall mounting (with IMT31A) Field mounting (with IMT33A) Ambient air temperature for operation - -40…120 °C compact with IMT30A -40…120 °C compact with IMT31A -40…140 °C compact with IMT33A product certifications - CE ATEX FM CSA Standards - IEC 60529