Basler Electric AEM-2020. Analog Expansion Module
Excitation System Accessories
AEM-2020. Analog Expansion Module
Designed to work with Basler’s DGC-2020. DGC-2020HD, DECS-250. DECS-250E, DECS-250N, and DECS-450.
the AEM-2020 easily increases the functionality of these products by seamlessly adding analog inputs and outputs to their array of configurations.
The AEM-2020 fully integrates into the PC software schemes and appears to the user as if it is internal to the DGC, DECS, and IEM.
For instruction manuals, refer to the DECS-250. DECS-250E, DECS-250N, DECS-450. DGC-2020HD, or DGC-2020 product page.
— Product Features & Benefits
Easily connects to compatible devices when additional analog I/O is required to meet difficult specifications.
A wide variety of analog inputs make this module extremely useful by adding flexibility that can eliminate expensive external devices.
Eight (8) 4-20 mA/0-10 Vdc inputs, eight (8) RTDs, two (2) thermocouple inputs, and four (4) fully-configurable analog outputs drive analog meters.
Rugged, potted design for the ultimate in reliability for extreme environmental applications.
Connects to compatible devices via CAN bus and automatically integrates into the BESTCOMSPlus® PC software. Fast to configure, simplifying commissioning of complicated systems.
Combine this additional I/O with the powerful programmable logic of the DGC-2020.
DGC-2020HD, DECS-250. or DECS-450 and eliminate the need for an additional PLC or other peripheral devices, saving installation and purchasing costs.
Easily assigned trip points for the analog inputs can be scaled by the user to directly reflect the measured parameter.
A wide variety of generator parameters can easily be integrated into an overall protection and metering scheme to meet virtually any specification.
Voltage Regulators
SR Retrofit, SSR Retrofit, Voltage Regulator
The SR and SSR Retrofits are economical, direct replacements for Basler’s SR and SSR voltage regulators.
These retrofits are designed for simple installation and require few system adjustments.
Installation into the same space previously occupied by a Basler Electric SR or SSR regulator without additional mounting holes and/or hardware.
Terminal-to-terminal wiring allows quick field replacement of the original voltage regulator.
Integrated CT input burden matching provides compatibility with paralleling systems utilizing cross-current compensation.
An accessory input provides compatibility with devices such as var/power factor controllers or excitation limiters.
Same reliable operation as the original SR/SSR being replaced.
Standard retrofit kits easily replace multiple models, including custom models, of the Basler SR and SSR voltage regulators.