Safe Torque Off (STO)
Anadditional digital input (STO) releases the poweroutput stageof thedriveas longas a24V signal is appliedto
this input. If the STO input goes open-circuit, then powerwill nolongerbesuppliedtothemotor, andthedrivewill
lose all torque and coast toastop.
Input STO (X1/3)
—Floating, reference groundis GND
—24V±10%,20mA
ThisinputisnotcompatiblewithIEC61131-2.
Youcanthus achievearestart lock-out forpersonnel safety by usingtheSTOinput inconjunctionwithanexter
nal safety circuit.
Advantages of theSTOfunction:
l TheDCbuslink remains charged, sincethemains supply lineremains active.
l Onlylow voltages areswitched, sothereis nocontact wear.
l Verylittle wiring is required.
TheSTOsafety concept is certified. Thesafety circuit concept usedforthesafety function"SafeTorqueOff" in
the drive is suited for SIL 2accordingtoEN 61800-5-2andPLd/ CAT3accordingtoISO13849-1.
6.17.1 Safety characteristic data
Thesubsystems (AKD)aredescribedwiththefollowingcharacteristic data:
Device
Operation Mode
EN13849-1
EN62061
STO STOsinglechannel
6.17.2 Use as directed
PLd,CAT3 SIL2
PFH[1/h]
SFF[%]

TheSTOfunctionis exclusively intendedtoprovidesafety forpersonnel by preventingtherestart of asystem.
Toachievethis personnel safety, thewiringof thesafety circuits must meet thesafety requirements of IEC
60204. ISO12100andISO13849.
6.17.3 Prohibited Use
TheSTOfunctionmust not beusedif thedriveis tobemadeinactiveforthefollowingreasons:
1. Cleaning, maintenanceandrepairoperations, longinoperativeperiods. Insuchcases, theentiresystem
should bedisconnectedfrom thesupply andsecured(mainswitch).
2. Emergency-stopsituations. Inanemergency-stopsituation, themaincontactoris switchedoff (by the
emergency-stopbutton).
Enclosure
SincethedrivemeetsIP20.youmustselectanenclosurethatpermitssafeoperationofthedrive.Theenclosure
mustatleastmeetIP54.
6.17.7 Wiring
Ifyouarewiringleadsthatareoutsidethespecifiedenclosure(IP54),thecablesmustbelaiddurably(firmly),pro
tectedfromoutsidedamage(forexample,bylayingthecableinaduct),placedindifferentsheathedcables,or
protectedindividuallybygroundingconnection.
WiringremainingwithinthespecifiedenclosuremustmeettherequirementsofthestandardIEC60204-1.