DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
OMRON C120-LK202-EV1/C120LK202EV1
❤ Add to collection

OMRON C120-LK202-EV1/C120LK202EV1

OMRON C120-LK202-EV1/C120LK202EV1

9177.00
¥8599.00
¥8599.00
¥8599.00
Weight:2.000KG
Description

OMRON C120-LK202-EV1/C120LK202EV1




OMRON C120-LK202-EV1

CPU Capabilities

The C200H-CPU21-E/CPU23-E/CPU31-E CPUs are based on the C200H

CPU11-E CPU, except only the CPU31-E supports Network Instructions. All of

the CPUs covered in this manual also support a group of High-density I/O Units

called Group-2 High-density I/O Units. Group-2 High-density I/O Units are clas

sified by themselves and are not classified as Special I/O Units.

The following table lists the capabilities of the various C200H CPUs.

Function CPU01-E CPU03-E CPU11-E CPU21-E CPU23-E CPU31-E

Compatible with Group-2 High-density I/O Units

(C200H-ID216/ID217/OD218/OD219)

No No No Yes Yes Yes

Can process GROUP-2 HIGH-DENSITY I/O

REFRESH – MPRF(61)

No No No Yes Yes Yes

Compatible with C200H-MR433/MR833/ME432

Memory Units

Yes1 Yes1 Yes1 Yes Yes Yes1

Compatible with C200H-ME832 Memory Unit No No No Yes Yes Yes1

Error history No No Yes Yes Yes Yes

Clock/calendar No No Yes Yes2 Yes2 Yes

Forced Status Hold Bit (SR 25211) No No Yes Yes Yes Yes

Can set TERMINAL mode for Programming

Console

No No Yes Yes Yes Yes

Additional instructions:

REVERSIBLE WORD SHIFT – RWS(17)

CYCLE TIME – SCAN(18)

MULTI-WORD COMPARE – MCMP(19)

LONG MESSAGE – LMSG(47)

TERMINAL MODE – TERM(48)

SET SYSTEM – SET(49)

DOUBLE COMPARE – CMPL(60)

COLUMN-TO-WORD – CTW(63)

WORD-TO-COLUMN – WTC(64)

HOURS-TO-SECONDS – HTS(65)

SECONDS-TO-HOURS – STH(66)

VALUE CALCULATE – VCAL(69)

No No Yes Yes Yes Yes

Network Instructions:

NETWORK SEND – SEND(90)

NETWORK RECEIVE – RECV(98)

No No Yes No No Yes

Power Supply AC DC AC AC DC AC

Note 1.The C200H-CPU01-E/CPU03-E cannot use the Memory Units’ clock, and

the C200H-CPU11-E/CPU31-E CPUs have a built-in clock.

2.The C200H-CPU21-E/CPU23-E can use the C200H-MR433/MR833/

ME432/ME832 Memory Units’ clock.

Introduction

Details, including the name, acronym, range, and function of each area are sum

marized in the following table. All but the last three of these areas are data areas.

Data and memory areas are normally referred to by their acronyms.

Area Acronym Range Function

Internal Relay IR Words: 000 to 235

Bits: 0000 to 23515

Used to control I/O points, other bits, timers,

and counters, and to temporarily store data.

Special Relay SR Words: 236 to 255

Bits: 23600 to 25507

Contains system clocks, flags, control bits, and

status information.

Auxiliary Relay AR Words: AR 00 to AR 27

Bits: AR 00 to AR 2715

Contains flags and bits for special functions.

Retains status during power failure.

Data Memory DM Read/write: DM 0000 to DM 0999

Read only: DM 1000 to DM 1999

Used for internal data storage and manipula

tion.

Holding Relay HR Words: HR 00 to HR 99

Bits: HR 0000 to HR 9915

Used to store data and to retain the data values

when the power to the PC is turned off.

Timer/Counter TC TC 000 to TC 511 (TC numbers used

to access other information)

Used to define timers and counters, and to ac

cess completion flags, PV, and SV. In general,

when used as a bit operand, a TC number ac

cesses the completion flag for the timer or

counter defined using the TC number. When

used as a word operand, the TC number ac

cesses the present value of the timer or count

er.

Link Relay LR Words: LR 00 to LR 63

Bits: LR 0000 to 6315

Available for use as work bits.

Temporary Relay TR TR 00 to TR 07 (bits only) Used to temporarily store and retrieve execu

tion conditions. These bits can only be used in

the Load and Output instructions. Storing and

retrieving execution conditions is necessary

when programming certain types of branching

ladder diagrams.

Program Memory UM UM: Depends on Memory Unit used. Contains the program executed by the CPU.

When some bits and words in certain data areas are not being used for their in

tended purpose, they can be used in programming as required to control other

bits. Words and bits available for use in this fashion are called work words and

work bits. Most, but not all, unused bits can be used as work bits. Those that can

be used are described area-by-area in the remainder of this section. Actual ap

plication of work bits and work words is described in Section 4 Writing and Input

ting the Program.

Some data areas contain flags and/or control bits. Flags are bits that are auto

matically turned ON and OFF to indicate particular operation status. Although

some flags can be turned ON and OFF by the user, most flags are read only; they

cannot be controlled directly.

Control bits are bits turned ON and OFF by the user to control specific aspects of

operation. Any bit given a name using the word bit rather than the word flag is a

control bit, e.g., Restart bits are control bits.


  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer