DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm
❤ Add to collection

Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm

Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm

5420.00
¥4522.00
¥4522.00
¥4522.00
Weight:2.000KG
Description

Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm


Beckhoff Polaris CP7011-1002-0010 operator operator HMI display 30.5 cm

Product Description

Appropriate Use

The CP70xx Control Panel is designed for industrial application in machine

and plant engineering. An aluminum housing contains a TFT display,

touch-screen/pad (optional), and a PC keyboard (optional). The panel is

installed via the 4 mounting holes in the backplane or the mounting arm

system adapter (optional).

The Control Panel must not be used where there is a risk of

explosion.  CP-Link connection

The CP-Link connection allows data transmission between Control Panel

and CP-Link-Interface card of the Industrial-PC and providing the Control

Panel with the supply voltage. Two coaxial cables are required, the cable

length between Control Panel and Industrial-PC amounts to at most 100 m.

The red point on the CP-Link card and the red marking at the coaxial cable

or at the bend protection allow better orientation while connecting the

CP-Link cable with BNC-connectors

C9900-K114 - Length 3 m (cable type Belden H155. bend radius 35 mm)

C9900-K115 - Length 5 m (cable type Belden H155. bend radius 35 mm)

C9900-K116 - Length 10 m (cable type Belden H155. bend radius 35 mm)

C9900-K117 - Length 15 m (cable type Belden H155. bend radius 35 mm)

C9900-K118 - Length 20 m (cable type Belden H155. bend radius 35 mm)

C9900-K119 - Length 30 m (cable type Aircell7. bend radius 25 mm)

C9900-K120 - Length 35 m (cable type H2000FLEX, bend radius 50 mm)

C9900-K121 - Length 50 m (cable type H2000FLEX, bend radius 50 mm)

C9900-K122 - Length 65 m (cable type H2000FLEX, bend radius 50 mm)

C9900-K123 - Length 70 m (for easy installation at the PC and the mounting

arm: 1 m Aircell7 + 61 m Cellflex + 8 m Aircell7)

C9900-K124 - Length 80 m (for easy installation at the PC and the mounting

arm: 1 m Aircell7 + 71 m Cellflex + 8 m Aircell7)

C9900-K125 - Length 90 m (for easy installation at the PC and the mounting

arm: 1 m Aircell7 + 81 m Cellflex + 8 m Aircell7)

C9900-K126 - Length 100 m (for easy installation at the PC and the mounting

arm: 1 m Aircell7 + 91 m Cellflex + 8 m Aircell7)

Dimensions a b t A B

CP7009 6.5“ Display 267.9 173 38 241.9 149

CP7000 10“ Display 353.8 308.3 27.5 327.6 280.7

CP7001 12“ Display 353.8 326.3 27.5 327.6 303.7

CP7002 15“ Display 426 395 28.5 399.8 367.4

M6 screw thread

Control Panel CP701x

Dimensions a b t A B

CP7019 6.5“ Display 267.9 213 38 241.9 189

CP7010 10“ Display 353.8 308.3 27.5 327.6 280.7

CP7011 12“ Display 353.8 326.3 27.5 327.6 303.7

CP7012 15“ Display 426 395 28.5 399.8 367.4

Control Panel CP702x

Dimensions a b t A B

CP7029 6.5“ Display 336 213 38 310 189

CP7020 10“ Display 406 308.3 27.5 374.8 280.7

CP7021-0000/1 12“ Display 406 308.3 27.5 374.8 280.7

CP7021-0002 12“ Display 439.8 308.3 27.5 408.6 280.7

CP7022 15“ Display 515 370.2 28.5 483.8 342.6

Control Panel CP703x

Dimensions a b t A B

CP7030 10“ Display 403.2 368.2 27.5 372.15 340.6

CP7031-0000/1 12“ Display 406 370.2 27.5 379.8 342.6

CP7031-0002 12“ Display 426 370.2 27.5 399.8 342.6

CP7037 12” Display 426 370.2 27.5 399.8 342.6

CP7032 15“ Display 483 410.2 28.5 458.8 387.6

Functional description

The Control Panel does not have its own mains power switch. As soon as

the power supply is switched on the control panel is activated.

Control software, as typically applied in Control Panels, enables the

assignment of different rights to all users. A user who is not entitled to shut

down the software may not switch off the Control Panel as an attempt to

shut it down when the software is running could result in the loss of

software data on the Compact Flash memory card.

If the control panel is shut down while the software is writing a file onto the

Compact Flash memory card, the file will be destroyed. Control software

typically writes something to the CF memory card every few seconds, so

that the probability of causing damage by switching off while the software is

running is very high.

The Control Panel’s membrane keypad may only be actuated by fingertips.


  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines