DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
MOOG  QAIO2/2-AV D137-001-011  Analog Extension Module
❤ Add to collection

MOOG QAIO2/2-AV D137-001-011 Analog Extension Module

MOOG  QAIO2/2-AV D137-001-011  Analog Extension Module

34520.00
¥26770.00
¥26770.00
¥26770.00
Weight:2.000KG
Description

MOOG  QAIO2/2-AV D137-001-011  Analog Extension Module


QAIO2/2-AV D137-001-011  Analog Extension Module   with Pulse Input

The QAIO 2/2 analog module is used for local extension of the inputs and outputs (I/O) of the Moog

Servo Controller (MSC) control module. The analog levels are identical to the levels of the MSC.

The module is mounted on a DIN top-hat rail and directly connected to the MSC via the internal

extension bus (E-Bus).

2.2 Features

Analog I/O extension module with pulse input.

• 2 analog inputs

• 2 analog outputs

• 1 reference voltage output +10 V

• Pulse input

• Connection via E-Bus

2.3 Outputs/Inputs

• 2 analog inputs, each configurable in the MACS development environment as ±10 V,

±10 mA or 4-20 mA. The inputs are converted in multiplex operation.

• 2 analog outputs, each ±10 V, additionally individually configurable in the MACS software

as ±10 mA, ±50 mA or 4–20 mA with wire fault monitoring

• 1 reference voltage output

The reference voltage source provides a short circuit protected voltage of +10 V.

• 1 pulse input 24 V useable as counter input or frequency measurement input

2.4

Module Status LEDs

On the front, 4 LEDs provide information about the status of important module functions.

2.5 Configuration

The configuration of the analog I/O is carried out per software via the central control configuration

in the Moog Axis Control Software (MACS) development environment.

Either the two analog inputs or the pulse input can be used.

2.6 Actuation

The I/O of the analog extension module is actuated directly from the MSC (not  D136X001-001 and

D136E001-001) via the extension bus (E-bus). All input- and output-data are transferred within one

cycle of the E-Bus. Therefore the module is perfect for fast control tasks.

2.7 E-Bus

One MSC can be extended with a maximum of 7 QAIO 2/2 modules. It is not possible to combine it

with QAIO 16/4 on one E-Bus segment.

Module data QAIO 2/2-AV I/O extension module

Order number D137-001-011

Connection to M3000 modules Via E-Bus (10 MHz)

Please note:

• It is not possible to connect the module to an MSC

D136X001-001 or D136E001-001

• Combination with QAIO 16/4 V or QAIO 16/4 A on

one E-Bus segment is not possible

• All QAIO 2/2 A/V modules must be connected next to

the E-Bus master MSC. Further E-Bus modules may

be connected right to the QAIO 2/2 A/V modules.

Connection technique Plug-in terminal strips for screwing or clamping

Mounting Mounting rail NS 35/7.5 pursuant to EN 50022 (DIN top-hat

rail)

4 module status LEDs Module functions and diagnosis

Dimensions, WxHxD 124 x 170 x 85.5 (attachment dimension: W = 113/118.5) mm

4.88 x 6.69 x 3.37 (attachment dimension:

W = 4.45/4.67) inch

Temperature range +5°C (+41°F) to +55°C (+131°F) (operation) and -25°C (-13°F) to +70°C (+158°F) (storage)

Mean temperature in operation for 24 hrs.: max. +50°C

(+122°F)

Relative air humidity 10 % to 95 % (non-condensing)

Operation height Max. 2000 m (6500 ft); storage/transport max. 3000 m

(9800 ft)

Standards

Operating equipment demands and

examinations

IEC 61131-2

Interference emission / immunity EN 61000-6-4 / EN 61000-6-2. industrial part

Shock / vibration IEC 60068 part 2-27 / IEC 60068 part 2-6

Protection class / protection system III / IP20

Insulation strength IEC 61131-2; test voltage 500 V DC

Energy Supply

Voltage supply of module

electronics

+24 V DC (18-32 V DC) SELV pursuant to DIN EN 60950-1

Current consumption of module

electronics

max. 0.25 A

Potential separation Separate potentials for: module electronics, 24 V energy

supply, pulse input

Internal voltages Internally generated via DC/DC converters

Protection against reverse polarity Yes

Analog Inputs

2 analog inputs 16 Bit; individually configurable in the MACS development

environment as ±10 V, ±10 mA or 4–20 mA;

overvoltage protection up to ±36 V

Analog Outputs

2 analog outputs 16 Bit; each ±10 V, additionally individually configurable in

the MACS development environment as ±10 mA, ±50 mA or

4–20 mA

Overvoltage protection up to ±36 V; short-circuit protected

Reference for sensors

Reference voltage output

+10 V; max. load: 5 mA

Overvoltage protection up to ± 36V; short circuit protected

Pulse input

Pulse input

24 V digital input can be used as input pursuant to IEC

61131-2 type 1

Positive switching (input OE) or ground switching

Either the two analog inputs or the pulse input can be used.

2.9 Accessories

Accessories

Designation

Plug-in terminal strips ( two 18-pole and one 9-pole are required per module)

Description

Screw terminal 18-pole

Order number

Up to max. conductor cross-section of 2.5 mm2

(14 AWG)

Screw terminal 9-pole

VK055-018

Up to max. conductor cross-section of 2.5 mm2

(14 AWG)

Spring latch clamp 18-pole

VK055-009

Up to max. conductor cross-section of 2.5 mm2

(14 AWG)

Spring latch clamp 9-pole

B95907-018

Up to max. conductor cross-section of 2.5 mm2

(14 AWG)

B95907-018


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI