DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch
❤ Add to collection

Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch

Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch

9870.00
¥7588.00
¥7588.00
¥7588.00
Weight:2.000KG
Description

Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch


Hirschmann RS20-2400T1T1SDAE Industrial Managed Ethernet Switch

The Hirschmann RS20-2400T1T1SDAE (Belden Part Number: 943 434-047) is a highly ruggedized, 24-port Fast Ethernet industrial managed switch designed by Hirschmann (a Belden brand).

Engineered specifically for harsh, demanding industrial environments, this switch provides deterministic data transmission, advanced layer 2 management capabilities, and redundancy mechanisms vital for factory automation, energy utilities, transportation systems, and water treatment facilities

Product Introduction / Overview

The RS20-2400T1T1SDAE is part of Hirschmann’s legacy OpenRail RS20 product group. This series is famous for its compact, DIN-rail mounting profile and hardened fanless chassis design.

This specific 24-port configuration features 24 twisted-pair copper ports (RJ45) that support 10/100 Mbit/s Fast Ethernet connections. Equipped with the Standard Software (SD) package, it supports essential industrial Layer 2 management options, including VLAN tagging, IGMP snooping, Quality of Service (QoS), and rapid redundancy protocols like RSTP and Hirschmann’s proprietary Hyper-Ring topology.

Technical Table

Parameter CategoryTechnical Specifications
Model CodeRS20-2400T1T1SDAE
Belden Order Number943 434-047
Product SeriesOpenRail RS20 (Compact Managed Switches)
Total Port Count24 Ports
Port Types & Speeds24 x 10/100 BASE-TX, RJ45 copper sockets (Auto-crossing, Auto-negotiation, Auto-polarity)
Operating Supply VoltageDual redundant inputs: 12 VDC to 48 VDC or 24 VAC
Power ConsumptionMax. 12.5 W
Software PackageStandard (SD) Software version
Redundancy ProtocolsHIPER-Ring (Ring Structure), RSTP 802.1D-2004, Redundant Network Coupling
Management InterfacesWeb-based Management (HTML), SNMP v1/v2/v3, Telnet, CLI, V.24 (serial port)
Diagnostics & MonitoringLEDs, Signal Contact (Fault Relay), Syslog, RMON, Port Mirroring
Safety CertificationscUL 508, ISA 12.12.01 Class 1 Div 2 (Hazardous Locations)
Mounting Type35 mm DIN Rail mounting
Chassis Dimensions (W x H x D)110 mm x 135 mm x 111 mm (Wide compact housing)
WeightApproximately 650 g (1.43 lbs)

Environmental & Storage Conditions

Environmental Tolerance Conditions

Ambient Operating Temperature: $0^circtext{C}$ to $60^circtext{C}$ (Standard industrial temperature range; fanless convection cooling).

Relative Humidity: 10% to 95% RH, strictly non-condensing.

Ingress Protection Level: IP20 (Must be protected from continuous water exposure and conductive metallic dust).

Shock & Vibration Resistance:

IEC 60068-2-27 (Shock): 15 g, 11 ms duration.

IEC 60068-2-6 (Vibration): 1 mm amplitude at 2–13.2 Hz; 0.7 g at 13.2–100 Hz.

Storage Conditions

Storage Temperature Range: $-40^circtext{C}$ to $70^circtext{C}$.

Storage Humidity: 10% to 95% non-condensing.

Anti-Static Safety: Keep the device inside its protective cardboard box and anti-static packaging during transport and long-term storage.

Operating & Installation Instructions

Installation Method

DIN Rail Mounting: Hook the top of the switch's integrated DIN clip onto the 35 mm rail and press downward until the bottom latch snaps firmly into place.

Safety Grounding: Connect the grounding screw at the bottom-left corner of the front plate directly to local machinery ground using a low-impedance wire.

Power Connection: Strip and insert power wires into the removable terminal block (V1+, V1-, V2+, V2-) to configure redundant DC supplies. Tighten terminal screws to prevent loose connections.

Signal Contact Integration: Wire the fault indicator relay contacts (FAULT) to an external alarm light or PLC digital input to monitor link-down or power failure events.

Operating Instructions

Apply Control Power: Turn on the redundant DC power supplies. The green power indicator LEDs (P1 and P2) on the front panel will illuminate.

Initial Network Connection: Connect a computer to one of the RJ45 ports. By default, the switch attempts to obtain an IP via DHCP. If no DHCP server exists, use the Hirschmann HiDiscovery tool or connect via the front RJ45 V.24 serial port using a terminal emulator to assign a static IP.

Web Interface Access: Open a web browser, enter the switch’s IP address, and log in to the system management portal to configure VLANs, redundancy, and port mirroring.

Fault Diagnosis

FAULT Red LED is Solid Red:

Potential Cause: Loss of power on one of the redundant DC inputs, or a monitored port link has dropped.

Correction: Verify that both V1 and V2 power supplies are operating. Check the web interface diagnostics to identify if a critical port connection has failed.

High Collision Rates or Slow Communication on RJ45 Ports:

Potential Cause: Duplex mismatch between the switch port and the connected end-device (e.g., half-duplex vs. full-duplex).

Correction: Change port settings from "Auto-Negotiation" to matching fixed duplex speeds on both sides (e.g., 100 Mbps Full-Duplex).

Ring Configuration Broken (Redundancy Alarm):

Potential Cause: An active ring connection in the network was disrupted, or the "Ring Manager" configuration was lost.

Correction: Verify cable continuity along all nodes of your industrial ring. Ensure that exactly one switch in the ring is designated as the active Ring Manager (RM).

Related Models in the Same Series

The Hirschmann OpenRail RS20 family offers various port combinations, copper/fiber options, and operating temperature grades:

RS20-1600S2S2SDAE: 16-port managed switch featuring 14 standard copper ports and 2 Single-Mode fiber ports (SC).

RS20-0800T1T1SDAE: Smaller 8-port compact variant featuring 8 standard RJ45 copper ports.

RS20-2400T1T1SDAU: Extended temperature version ($0^circtext{C}$ to $60^circtext{C}$) with standard software and special hazardous location approvals.

RS20-2400T1T1SDAH: High-temperature variant designed to operate reliably in severe conditions from $-40^circtext{C}$ up to $70^circtext{C}$.


  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter