DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator
❤ Add to collection

BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator

BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator

9640.00
¥8855.00
¥8855.00
¥8855.00
Weight:2.000KG
Description

BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator


BASLER ELECTRIC SR4A-2B15B3A Static Voltage Regulator

Once the list of annunciation messages has been viewed, it may be cleared by pressing the Reset

pushbutton. If a condition that LED to an annunciation is still present when the alarm message screen is

cleared, then a new annunciation message will be generated.

Pressing the Reset pushbutton will also send the display back to the Metering screen. Furthermore, the

alarms message on the Metering screen will also be cleared. However, if the user leaves the alarm

message screen by pressing  the Left, Right or Up scrolling pushbuttons, then the annunciation

messages list remains intact. This allows the user to maintain a short history of annunciations. In addition,

the alarms message on the Metering screen will also remain. The disadvantage of this is that the

metering screen would no longer indicate that a new annunciation occurred because the alarms message

would always be present.

Screens with Special Editing Modes

There are several screens that operate differently while in the edit mode. OPERATE_1 (1.1),

BAUD_RATE (8.1.1), and MODBUS (8.1.2) are examples of such screens. In each case, any changes

made to a setting are not used by the system (nor saved in nonvolatile memory) until the Edit pushbutton

is pressed again.  The programmable inputs for output relays 1 through 4 work in the same manner.

These are on screens RELAY_1 (7.5.1) through RELAY_3B (7.5.9).

The REG_GAIN (3.1) screen also operates in a different manner when in the Edit mode. The first four

parameters on this screen represent a table containing twenty sets of predefined PID values and one set

of user-definable values. The first of these, STAB SET #, which means stability settings number, is the

index to the table. The second, third, and fourth parameters (AVR/FCR Kp, Ki, and Kd), are the actual

entries in the table. Stability setting numbers 1 to 20 are the predefined values, and 21 is the set of user

definable values.

Editing these parameters works as follows:  As long as STAB SET # is set to 21. then AVR/FCR Kp, Ki,

and Kd may be individually edited and customized. The values displayed are not used by the system until

they are saved by pressing the Edit pushbutton. This means that if a change is aborted by pressing the

Reset pushbutton, the PID numbers currently being used by the system remain unchanged.

If STAB SET # is 1 to 20. then AVR/FCR Kp, Ki and Kd may not be edited from the display (although the

cursor can be moved to their display fields). If the STAB SET # is changed, the values shown in the

display fields will not change until the selected STAB SET # is saved. When the STAB SET # is saved,

the table entries are saved, used by the system and displayed on the LCD.

If the DECS-200 is using the user-defined values previously set at STAB SET # 21 and a STAB SET # of

1 to 20 is saved, the user-defined values are lost. The next time that user-defined values for STAB SET #

21 are required, they must be manually entered and then saved. It is assumed that the table entries for

STAB SET # 1 to 20 will be used as starting points from which users will arrive at their own customized

values after the selected starting point has been saved (and thus copied into STAB SET # 21).

Menu Tree

The menu tree has eight branches:

1. OPERATING. Displays mode status and on or off status (AVR, FCR, var, PF, etc.)

2. SETPOINTS. Display and setting of mode values (AVR, FCR, var, PF, etc.)

3. LOOP GAINS. Loop gains for each element are set here (Kp, Ki, Kd, Kg)

4. METERING. Real-time metering of user-selected values and alarm messages.

5. PROTECTION. Display and setting of protective function parameters such as pickups.

6. LIMITERS. Display and setting of system limiters (OEL, UEL, etc.)

7. SYSTEM PARAMETERS. Display and setting of system parameters. This menu item consists of nine

sub-branches:


  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module