DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ABBDCS Thyristor Power Converters for DC Drive Systems 25 to 5150 A Operating Instructions DCS 600 MultiDrive

From:ABB | Author:LIAO | Time :2025-08-28 | 849 Browse: | 🔊 Click to read aloud ❚❚ | Share:

functions should not be used if other units and devices are not

suitable for an operating mode of this kind, or if their use might

entail dangerous situations.

Warning of electrostatic discharge:

this symbol warns you against electrostatic discharges which may damage the unit. Where appropriate, the text printed next to this symbol describes

how a risk of this kind may be avoided.

Notes Notes supply information on states requiring particular attention, or

indicate that additional information is available on a specific topic.

For this purpose, the following symbols are used:

CAUTION! Cautions are designed to draw your attention to a

particular state of affairs.

Note A note contains or refers you to additional information available on the particular topic concerned.

Mains connection You can use a switch disconnector (with fuses) in the power supply

of the thyristor power converter to disconnect the electrical components of the unit from the power supply for installation and maintenance work. The type of disconnector used must be a switch disconnector as per EN 60947-3, Class B, so as to comply with EU

regulations, or a circuit-breaker type which switches off the load

circuit by means of an auxiliary contact causing the breaker’s main

contacts to open. The mains disconnector must be locked in its

"OPEN" position during any installation and maintenance work.

EMERGENCY STOP

buttons

EMERGENCY STOP buttons must be installed at each control

desk and at all other control panels requiring an emergency stop

function. Pressing the STOP button on the CDP 312 control panel

of the thyristor power converter will neither cause an emergency

motor stop, nor will the drive be disconnected from any dangerous

potential.

To avoid unintentional operating states, or to shut the unit down in case of

any imminent danger according to the standards in the safety instructions

it is not sufficient to merely shut down the drive via signals „RUN“, „drive

OFF“ or „Emergency Stop“ respectively „control panel“ or „PC tool“.

Intended use The operating instructions cannot take into consideration every

possible case of configuration, operation or maintenance. Thus,

they mainly give such advice only, which is required by qualified

personnel for normal operation of the machines and devices in

industrial installations.

If in special cases the electrical machines and devices are intended for use in non-industrial installations - which may require

stricter safety regulations (e.g. protection against contact by

children or similar) -, these additional safety measures for the

installation must be provided by the customer during assembly

How to use this manual The purpose of these operating instructions is to provide detailed

information on how to start up a thyristor power converter from the

DCS 600 series.

Note: If it is not mentioned explicitly all details given in

these Operating Instructions will be valid for series

DCS 600!

Contents of this manual Chapter 1 - Introduction

It describes how to use this manual and the boundary conditions

applying.

Chapter 2 - Start-Up Instructions

We recommend working your way through the Start-Up Instructions

step by step, since in this way you will get to perform all important

parameter setting routines.

Chapter 3 - How to Handle the Control and Display Panel

This chapter describes how to operate the CDP 312 control and

display panel.

Chapter 4 - Signals and Troubleshooting

This chapter describes the available signals and possibilities of display with DCS 600. As far as fault signals are concerned there will

be indicated measures (actions) to be taken for troubleshooting.

Target group This manual is designed to help those responsible for planning, installing, starting up and servicing the thyristor power converter.

These people should possess

• basic knowledge of physics and electrical engineering, electrical

wiring principles, components and symbols used in electrical engineering, and

• basic experience with DC drives and products.

Associated

publications

The DCS 600 documentation includes the following:

System Descriptions DCS 600

Technical Data DCS Thyristor Power Converters

Software Description DCS 600

Service Manual

12-Pulse Manual

Installation Manual

DCS 600 - 



   

 









These Operating Instructions

Incoming inspection After opening this package, you should check whether it contains

the following items:

● DCS 600 thyristor power converter in the configuration

ordered

● DCS 600 publications

● Accessories, including manuals if ordered

● Final test report

Check the consignment for any signs of damage. If you find any,

please contact the insurance company or the supplier.

Check the particulars given on the unit’s rating plate to make sure

prior to installation and start-up that you have received the correct

unit type and unit version.

If the consignment is incomplete or contains any incorrect items,

please contact the supplier.

CAUTION! The thyristor power converter weighs quite a lot and

should therefore not be held by the front cover. Please put the unit

down only on its back (sizes C1 to C3). Always use due care when

handling the unit, so as to avoid injuries or damage.

Storage and transport If the unit had been in storage prior to installation or is transported

  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card
  • Adlink Centralized Motion Controllers PCI-8164
  • ADLINK PCI-7230/33/34 32-CH Isolated DIO PCI Cardsrd
  • ADLINK NUPRO-E320DV/NUPRO-E320 industrial control motherboard
  • Adlink PCI-8154 Advanced 4-axis Servo & Stepper Motion Controller
  • Adlink cPCI-3534/3538-S Series 4/8-port Asynchronous Serial Communications Modules
  • ADLINK Adlink Digital I/O PCI-7396
  • ADLINK 6U Rear Transition Modules cPCI-R6700 Series
  • ADLINK cPCI-6700B Industrial Control Board
  • ADLINK NuPRO-965/ NuPRO-965LV PICMG Single Board Computers
  • ADLINK HSL-DI16DO16-M-NN 16-CH Discrete Input 16-CH Discrete Output Module
  • Adlink cPCI-6770 6U CompactPCI 2.0 Blades
  • ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
  • ADLINK PCI-7200 PCI Motion Control Card Acquisition Card 51-12001-0C20
  • ADLINK TECHNOLOGY EOS-1200/M4G/SSD32G(G) Industrial Systems
  • ADLINK Centralized Motion Controllers PCI-8134
  • ADLINK cPCI-HR6847E/M2G-1 COMPACT PCI BOARD
  • ADLINK PXIE-8638 BUS EXPANSION MODULE
  • ADLINK cPCI-6910 6U CompactPCI 2.0 Blades
  • Adlink NuPRO-E42 51-41808-0A30 Industrial Motherboard
  • ADLINK IH61-AA400-A4A1E (IMB-M40H) Industrial Motherboard
  • ADLINK PCIe-GIE64+ GigE Vision Frame Grabber Card
  • ADLINK MXC-6322D(G) Industrial Fanless Computer working