DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

HoneywellEXPERION PKSSeries C I/O User's Guide EPDOC-X126-en-A November 2019

From:Honeywell | Author:LIAO | Time :2025-08-19 | 999 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

ABOUT THIS GUIDE

The procedures in this guide are intended to give you the ability to perform basic tasks with the

Series C I/O such as configuring hardware devices, continuous control strategies. Respective

forms are displayed to illustrate a procedure/concept only.

1.1 Revision History

Revision Date Description

A November 2019 Initial release of the document.

l Intended audience

l Prerequisite Skills

l References

l Terms and acronyms

1.2 Intended audience

This guide is intended for the following users:

l Persons responsible for system planning, initial hardware installation, and control strategy

configuration

l Operators who help to maintain control system operations on a day-by-day basis

l Service persons responsible for routine maintenance of control hardware, and who diagnose

and repair faults.

1.3 Prerequisite Skills

It is assumed that you should have some knowledge of Experion control systems and experience

of working in a Microsoft Windows environment.

1.4 References

Listed here are the documents that contain general information for planning and implementing

control hardware and network communications in your Experion system:

 Control Hardware Planning Guide - Provides general information to assist you in planning

and design of control hardware in an Experion system. Control hardware includes C200

Controllers, Series A Chassis I/O and FIMs, also, all I/O families, (except Series C I/O). It

includes some supervisory network considerations for general reference.

l C300 Controller Guide - This guide provides information that will assist you in planning and

designing activities, as well as the installation, operation, and troubleshooting of Series C300

Controllers in an Experion system.

l Series C Fieldbus Interface Module (FIM) User Guide - Provides planning and implementation

guide for the Series C Fieldbus Interface Module.

l Fault Tolerant Ethernet Overview and Implementation Guide - Provides basic installation

instructions and configuration requirements for a Fault Tolerant Ethernet (FTE) network and

its components.

l Fault Tolerant Ethernet Installation and Service Guide - Contains instructions for installing

and configuring a Fault Tolerant Ethernet (FTE) node. The guide includes troubleshooting

and service information for an FTE node.

l Fault Tolerant Ethernet Bridge Implementation Guide - Provides information for

implementing a Fault Tolerant Ethernet supervisory network through the FTE Bridge module.

It includes module installation, configuration, operation and service data.

l Process Manager I/O Troubleshooting and Maintenance Guide - Guide features notification

messages (soft fail codes and hard fail codes), service procedures and parts lists for PM I/O

control hardware.

1.5 Terms and acronyms

The following table summarizes the terms and type representation conventions used in this guide.

Term/conventions Meaning Example

Click Click left mouse button once. (Assumes cursor is

positioned on object or selection.)

Click the Browse

button.

Double-click Click left mouse button twice in quick succession.

(Assumes cursor is positioned on object or selection.)

Double click the

Station icon.

Drag Press and hold left mouse button while dragging cursor to

new screen location and then release the button.

(Assumes cursor is positioned on object or selection to be

moved.)

Drag the PID

function block

onto the Control

Drawing.

Right-click Click right mouse button once. (Assumes cursor is

positioned on object or selection.)

Right-click the

AND function

block.

<F1> Keys to be pressed are displayed in angle brackets. Press <F1> to view

the online Help.

<Ctrl>+<C> Keys to be pressed together are displayed with a plus sign. Press <Ctrl>+<C> to

close the window.

File->New Shows menu selection as menu name followed by menu

selection

Click File->New to

start new drawing.

>D:setup.exe< Data to be keyed in at prompt or in an entry field. Key in this path

location

>D:setup.exe<.

SERIES C I/O PURPOSE

Series C I/O Modules, along with I/O Termination Assemblies (IOTAs), perform module diagnostics

input and output scanning and processing on all field I/O data and events. To allow a more

efficient use of Controller resources, I/O processing is performed separately from control

processing functions so that:

l I/O sample rates are completely independent of I/O quantity, controller loading, processing,

and alarming

l allows more efficient use of advanced Control Processor capability, and

l provides for future I/O expansion.

l Comparing Process Manager I/O and Series C I/O

l What is Series C I/O?

l Series C Pulse Input Module (SCPIM)

l What is Universal Input/Output (UIO) Module?

l What is Low Level Analog Input (LLAI) Module

l Overview of the Universal Horizontal Input/Output (UHIO)

2.1 Comparing Process Manager I/O and Series C I/O

The following list compares previous features of the Process Manager I/O and the Series C I/O:

l Non-Volatile Memory:

o In the PM, memory was maintained over a power cycle within the I/O card itself.

o With the Series C I/O, the configuration memory information is restored from the

C300 controller at power-up of the I/O Module.

l IOL - The Series C I/O link runs at twice the speed of the PMIO I/O Link. Each C300 I/O Link

  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170    CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module, Microsoft Windows Embedded Standard 7 P
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module, Microsoft Windows Embedded Compact 7
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190  CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170    CPU module
  • Beckhoff CX5230-0100   CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC
  • Beckhoff  CX5130-0163 CPU module
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161 CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143    CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125  CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121    CPU module
  • Beckhoff CX5130-0115    CPU module
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112 CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100 CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return
  • SAUTER ASF113F122 Damper actuator with spring return