DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ProcessLogix R500.1 Selection Guide

From:A-B | Author:LIAO | Time :2025-08-13 | 1426 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Important User Information Because of the variety of uses for the products described in this publication, 

those responsible for the application and use of these products must satisfy 

themselves that all necessary steps have been taken to assure that each 

application and use meets all performance and safety requirements, including 

any applicable laws, regulations, codes and standards. In no event will 

Allen-Bradley be responsible or liable for indirect or consequential damage 

resulting from the use or application of these products.

Any illustrations, charts, sample programs, and layout examples shown in this 

publication are intended solely for purposes of example. Since there are many 

variables and requirements associated with any particular installation, 

Allen-Bradley does not assume responsibility or liability (to include intellectual 

property liability) for actual use based upon the examples shown in this 

publication.

Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation 

and Maintenance of Solid-State Control (available from your local Allen-Bradley 

office), describes some important differences between solid-state equipment 

and electromechanical devices that should be taken into consideration when 

applying products such as those described in this publication.

Reproduction of the contents of this copyrighted publication, in whole or part, 

without written permission of Rockwell Automation, is prohibited.

Throughout this publication, notes may be used to make you aware of safety 

considerations. The following annotations and their accompanying statements 

help you to identify a potential hazard, avoid a potential hazard, and recognize 

the consequences of a potential hazard:

Allen-Bradley is a trademark of Rockwell Automation

ATTENTION

!

Identifies information about practices or circumstances 

that can lead to personal injury or death, property damage, 

or economic loss.

IMPORTANT Identifies information that is critical for successful 

application and understanding of the product.

Minimum Hardware 

Requirements

ProcessLogix R500.1 Server Software must be installed on a PC that is 

specifically qualified. Use of any other PC variations will render the standard 

warranty and support agreement null and void.

There are two methods of obtaining the qualified ProcessLogix Server:

1. Purchase the Server from Rockwell Automation.

2. Contact Rockwell Automation Technical Support for further 

information on ordering specifically qualified hardware.

Contents of the 

ProcessLogix R500.1 

Release

The following software and documentation components are included in the 

ProcessLogix R500.1 Software/documentation kit (1757-SWKIT5000).

Table P.1 ProcessLogix R500.1 Release Components

Release Components Pub/Part Number

ProcessLogix R500.1 Base Software CD

• SQL Server 2000

957678-70

ProcessLogix R500.1 Application Software CD

• ProcessLogix Engineering Tools

• ProcessLogix Server Software

• RSLinx 2.31

957678-71

ProcessLogix R500.1 Supplemental Software CD 957707-19

ProcessLogix Knowledge Builder CD 957678-69

ProcessLogix R500.1 Selection Guide 957689-94

Our Assumptions About 

Users When Installing 

ProcessLogix R500.1

Before configuring a ProcessLogix system you must:

• Be familiar with navigating and running applications in a Microsoft 

Windows 2000 environment.

• Have some experience in loading software applications on a personal 

computer (PC).

• Be familiar with ProcessLogix hardware components.

• Be familiar with ControlNet or ENET configuration.

• Be trained on ProcessLogix, including Control Builder and Server 

components.

• If applicable to your system, you must also have appropriate training on 

other Rockwell Automation products applicable to ControlLogix, 

RSNetworx, and DeviceNet.

Starting Conditions and Assumptions for Installing ProcessLogix 

R500.1

You have the following items on hand:

• ProcessLogix R500.1 Base Software CD containing software such as 

SQL.

• ProcessLogix R500.1 Application Software CD containing ProcessLogix 

applications software.

• ProcessLogix R500.1 Knowledge Builder CD containing the latest 

version of the online documentation.

• Microsoft Windows Operating System(s) CD(s).

• RSLinx OEM Master (Activation) Disk.

IMPORTANT If you have not received ProcessLogix R500.1 training, we 

recommend that you find someone who does have 

experience to assist you in loading the ProcessLogix 

software and making hardware and firmware changes in 

associated ProcessLogix hardware components.

Contact your local sales office for more information about 

training schedules and available trained personnel

You must be certain that your PC meets the hardware requirements for a 

ProcessLogix Server or ProcessLogix Client.

• ProcessLogix Servers require a Windows 2000 Server operating system. 

Refer to ProcessLogix Online User Documentation/Knowledge Builder 

on page P-3 for information about ProcessLogix Server hardware.

• ProcessLogix Client Stations require a Windows 2000 Professional, XP 

  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module